[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650431-105":59,"doc-detail-650431-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","cattle-grid-grid-arrangement-plan","CATTLE GRID - GRID ARRANGEMENT PLAN","","Cattle grid design and construction requirements for rural roads, including an in-ground and above-ground grid arrangement plan with profile guidance that varies by existing grades. Specifies grid design life (50 years) as frangible for safety, allowable placement and minimum clear widths, traffic load assumptions (10 tonne axle, 5 tonne wheel), and design load factors aligned with relevant standards. Details rail and wing materials and dimensions, anchorage and subgrade bearing/CBR requirements, self-draining grid pit configuration, pavement/seal approach and end treatments, and corrosion protection (hot-dip galvanising) with compliance to approved council specifications and approval documentation.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/cattle-grid-grid-arrangement-plan/650431/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/cattle-grid-grid-arrangement-plan/650431.png","ImageObject",300,407,{"name":92,"@type":93},"putri.kecil17","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the specified design life and frangibility requirement for the cattle grid?","Question",{"text":112,"@type":113},"The cattle grid design life is 50 years and the grid must be frangible.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What traffic loads and design load factors are used for the cattle grid?",{"text":117,"@type":113},"Design traffic loads include a 10 tonne axle load and 5 tonne wheel load; design load factors are set in accordance with the referenced standard (AS 5100.2-2004).",{"name":119,"@type":110,"acceptedAnswer":120},"What are the subgrade requirements for supporting the cattle grid?",{"text":121,"@type":113},"The subgrade bearing pressure must be a minimum of 100 kPa and the minimum soaked CBR is 10% (or approved equivalent).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650431,1792827939,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":81},962094509873,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","CATTLE  \nwg0  \nMAX  \n30m  \n5m FLAT  \nGRID  \n5m FLAT  \n30m  \n(BITUMEN)  \n(BITUMEN)  \n1 IN 50  \n1 IN 50  \nBRC(09/10)  \nABOVE GROUND GRID ARRANGEMENT PROFILE(PROFILE IS INDICATVE AND WILL VARY WITH EXISTING GRADES.)  \n40m  \n40m  \n\n| NOTE:  \u003Cbr>THIS GRID OPTION IS INTENDED FOR LOW ORDER  \u003Cbr>GRAVEL ROADS AND IS ONLY TO BE USED WITH  \u003Cbr>THE EXPRESS APPROVAL OF BRC'S MANAGER OF  \u003Cbr>ROADS AND DRAINAGE SERVICES OR HIGHER.   |\n| --- |\n\nR6-1A  \n从看  \nW5-16A  \n另  \n10m MN  \n5m CATE  \nGRID  \nLAN3  \nW8-16A  \nONE  \nAREA TO BE KEPT CLEARED  \nAND TRAFFICABLE  \n十  \nBITUMEN一  \nGUIDE POST  \nGUIDF POST  \nCARRIAGEWAY  \n(NOTE6)  \n5m MIN  \n5m MIN  \n大  \n十  \n10m  \n10m  \nGRID  \nLANE  \nW8-16A  \n               80m  \n60m  \n80m  \n                60m     \nCATTLE GRID  \nW5-16A  \n誉  \nONE  \nSNISSYd  \nR6-1A  \n旨  \n# GRID ARRANGEMENT PLAN\n\nIN GROUND GRIDABOVE GROUND GRIDNOTES 800          4000(NOTE 4)         8001.CATTLE GRID DESIGN LIFE SHALL BE-FRANGIBLE RURAL FENCE TO    IN GROUND GRID      ABOVE GROUND GRID   50 YEARS.BE UP TO 5m FROMTRAFFIC LANE20°WIDTH MARKER-23252.DESIGN TRAFFIC LOADS:10 TONNE AXLELOAD,5 TONNE WHEEL LOAD.D4-3ACONNECT GRID WINGS TO FENCETHESE LOADS ACCOUNT FOR STANDARD MASSRHS 115X42X2-RIGID TRUCKS,TRAILERS,SEMI-TRAILER  \nWIDTH MARKER·  \nGRID RAILS ◎ 225 CRS-GRID WINGFRANGIBLE POSTCOMBINATIONS.AND B-DOUBLES.DESIGN LOAD FACTORS TO AS 5100.2-2004.75X75X5 SHS -C450L03.ALL WORK AND MATERIALS SHALL COMPLYOR 22kg/m RAIL LINEBEARERS @700 CRS MAX@203 CRS250 UB 26BITUMEN·BITUMENWITH BUNDABERG REGIONAL COUNCIL(BRC)SPECIFICATIONS,STANDARDS,&COVERINGAPPROVAL LETTER.  \n1000  \n4.ALTERNATIVE CERTIFIED GRIDS RATED FOR THEENSURE FULL BEARING OFSAME LOADS OR GREATER AND ALTERNATIVEFRANGIBLE WINGS MAY BE USED WHEREHEADSTOCK ON SUBGRADE  \nMAX  \n009  \nCUT OUTLETREFER NOTE 11 FORAPPROVED BY BRC. A TYPE SECTIONTO GRID PITSUBGRADE REQUIREMENT5.GRID IS SUITABLE FOR IN GROUND OR ABOVECONCRETE HEADSTOCK ON PREPARED-ANCHORAGE-SITE DEPENDANT.SURFACE APPROVED BY BRC ENGINEER(SEE DETAIL)BTYPE SECTIONSELF DRAINING GRID PITCONCRETE6.GRID APPROACH AND DEPARTURE TO HAVEHEADSTOCKPAVEMENT/SEAL AT EACH END WITH AMINIMUM OF 4m WIDE AND A LENGTH OF 5m.          4000(NOTE 7)          PAVEMENT AND SEAL AS DIRECTED BY BRCENGINEER.  \n(8)yg-t一250700700MAXMAX7oo700700250MAXMAXE(7)g-+02X N20 BARS·    550    65X167.MINIMUM UNOBSTRUCTED GRID WIDTH TO BE                            D250300FLAT BAR4.0m UNLESS NOTED OTHERWISE(UNO)IN8908°N12 TIES @200 CRS·11525X256BRC APPROVAL LETTER.a50mm COVERCHAMFERS6-22Ø8.THE ROAD SIGNS SHOWN ON THIS PLAN ARE回可THE MINIMUM STANDARD AND SUBJECT TO220CONDITONS SETOUT IN COVERING APPROVALROCK SPALL TO BATTER65X16LETTER.16 DIA.ROD WELDED TO TOP·(ABOVE GROUND GRID)FLAT BAR9.SIGNS TO BE ERECTED AS PER MUTCD.OF RAILS WITH 4mm FW.10.ALL EXPOSED STEELWORK INCLUDING HOLD20mmDOWN BOLTS SHALL BE HOT-DIP GALVANISED.10 TO 20mm MORTAR PADGALV.11.SUBGRADE BEARING PRESSURE TO BE MIN.PARCHEM RENDEROC HB40THREADED100kPa.MINIMUM SOAKED CBR 10%.OR APPROVED EQUIVALENTBAR12.CONCRETE GRADE IS TO BE N32 EXCEPT FORA依2X227LOCATIONS WITHIN 1km OF THE COASTN12BARSANCHORAGE(SEE DETAIL)—CONCRETE(NOTE 12)160-1M20 NUTWHERE N40 IS TO BE USED.CLASS 513.ALL CONCRETE TO BE POURED AT 80 SLUMP  \n160HOLES  \n335  \n570  \n870 MIN  \n550  \n235  \nawingslRoadsR2101 Catle Grd |14/04/20168:26:05 AM  \n300 MN  \n&WASHER&MECHANICALLY VIBRATED.HEADSTOCK3X N20 BARS·ANCHORAGECONCRETE IS TO BE MOIST CURED FOR 3DAYS MINIMUM.D4-3A(L)CONCRETEBTOP&BOTTOMN12 TIES ◎ 200 CRS,50mm COVERDETAIL14.ALL DIMENSIONS ARE IN MILLIMETRES UNO.D4-3A(R)CONCRETE HEADSTOCK DETAILScales  \nHEADSTOCK  \nR:Support SenicesDesign'Standards &  \nPLAN  \n\n| Standard  \u003Cbr>Drawing  \u003Cbr>No.:  \u003Cbr>R2101   | Sheet  \u003Cbr>Size:  \u003Cbr>A3   |\n| --- | --- |\n|  | Rev.:  \u003Cbr>A   |\n\nDate  \nRevisions  \nQuality Cerification  \nVerified  \nDesign:  \nVerified:  \nDrawn:Tifa  \nChecked:  \nNOT TO SCALECattle Grid  \nDigitaly signed by Mary Hdmes  \nBUNDABERG我EG10NL     阻CIL  \nDN:cn=Mary Hdmes,o=Hdmes McLeod Corsuling  \nEngners PtyLd,ou-Diehor-Smnior Sructura  \nEngines,mail","cbCaimEAzKbxzT2Z","https://ap.wps.com/l/cbCaimEAzKbxzT2Z","pdf",580390,"English","# GRID ARRANGEMENT PLAN\n## NOTES AND DESIGN REQUIREMENTS","[{\"question\":\"What is the specified design life and frangibility requirement for the cattle grid?\",\"answer\":\"The cattle grid design life is 50 years and the grid must be frangible.\"},{\"question\":\"What traffic loads and design load factors are used for the cattle grid?\",\"answer\":\"Design traffic loads include a 10 tonne axle load and 5 tonne wheel load; design load factors are set in accordance with the referenced standard (AS 5100.2-2004).\"},{\"question\":\"What are the subgrade requirements for supporting the cattle grid?\",\"answer\":\"The subgrade bearing pressure must be a minimum of 100 kPa and the minimum soaked CBR is 10% (or approved equivalent).\"}]","CATTLE GRID - GRID ARRANGEMENT PLAN | PDF"]