[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-363951-105":59,"doc-detail-363951-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","carlon-pvc-elbows-conduit-fittings-pvc-conduit-repair-system-job-in-two-minutes","Carlon PVC Elbows, Conduit & Fittings - PVC Conduit Repair System - Job in Two Minutes","","Carlon PVC Elbows, Conduit & Fittings catalog section details a PVC Conduit Repair System designed to significantly cut the time and cost of repairing broken PVC conduits (“stub-ups”) in concrete slabs. The system uses couplings, adapters, reamers, and plugs to enable quick repairs while maintaining the conduit’s inside diameter. Content includes installation and cementing instructions, features such as cULus listing and NEC/Section 352.6 compliance, and benefits including corrosion resistance and faster turnaround.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/carlon-pvc-elbows-conduit-fittings-pvc-conduit-repair-system-job-in-two-minutes/363951/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/carlon-pvc-elbows-conduit-fittings-pvc-conduit-repair-system-job-in-two-minutes/363951.png","ImageObject",300,407,{"name":92,"@type":93},"anakgang17","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-09-27","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What problem does the Carlon® PVC Conduit Repair System solve?","Question",{"text":112,"@type":113},"It reduces the time and money needed to repair broken PVC conduits in concrete slabs (stub-ups). The system is designed for faster repairs without extensive concrete removal and re-pouring.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the repair process work at a high level?",{"text":117,"@type":113},"Cut off the broken conduit, ream the inside diameter, and insert a coupling or adapter while maintaining the conduit’s inside diameter.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the key cementing instructions for installing couplings and adapters?",{"text":121,"@type":113},"Clean the socket I.D. and spigot O.D., apply a uniform cement coat to the spigot end, push onto the socket bottom while rotating a quarter turn, and allow time to set before disturbing.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},363951,1790331684,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962090883568,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Carlon® PVC Elbows, Conduit & Fittings  \nIn this section...  \nCarlon® PVC Elbows, Conduit & Fittings  \nElbows, Sweeps and Accessories ............................... E-454–E-481  \nConduit Bodies (for use with Schedule 40  \nand 80 Conduit) .......................................................... E-482–E-487  \nSwitch and Junction Boxes ......................................... E-488–E-492  \nStraps, Clamps and Accessories ................................. E-493–E-496  \nSpacers ...................................................................... E-497–E-502  \nP&C Flex® Conduit and Fittings ................................... E-503–E-507  \nCarflex® Liquidtight Flexible Conduit and Fittings ........ E-508–E-515  \nTechnical Information ................................................. E-516–E-518  \nConduit & Fittings—Carlon® PVC Elbows, Conduit & Fittings  \nE-454  \nElbows, Sweeps and Accessories  \nA job that normally takes 20 minutes—DONE in two minutes or less! Carlon® PVC Conduit Repair System  \nThe new, revolutionary design Carlon® PVC Conduit Repair System significantly reduces the time and money associated with repairing broken PVC conduits, a. k.a.“stub-ups”, in concrete slabs.  \nThe system includes a line of couplings, adapters, reamers and plugs designed to enable contractors to quickly and easily repair broken PVC conduits without having to chip away and repour concrete, while still maintaining the inside diameter of the conduit. Simply cut off the broken conduit, ream the I. D. of the conduit and insert a coupling or adapter. It’s that easy. A job that normally takes 20 minutes can now be done in two minutes or less!  \nFeatures:  \n• cULus Listed  \n• PVC repair fittings are listed in accordance with the NEC® and Section 352.6  \n• Non-metallic couplings, adapters and plugs won’t rust or corrode  \n• Available in sizes 1⁄2 \" through 2\"  \nBenefits:  \n• Saves time and money  \n• Maintains inside diameter of conduit  \n• Metallic reamers for extra strength, durability and longer life  \n• Quickly and easily repair broken PVC conduits  \nNEC and National Electrical Code are registered trademarks  \nof the National Fire Protection Association, Inc.  \nMale Threaded Adapter  \nMale Threaded Adapters  \n| CAT. No. | TrAdE SizE (iN.) | STd. CTN. |\n| --- | --- | --- |\n\nE920d 1⁄2 25  \nE920E 3⁄4 25  \nE920F 1 15  \nE920G 11⁄4 10  \nE920H 11⁄2 10  \nE920J 2 10  \nSchedule 40 Plugs  \nE2969  \nReamer Kit  \nCoupling  \nreamers  \n\n| CAT. No. | TrAdE SizE (iN.) | STd. CTN. |\n| --- | --- | --- |\n\nE910rEAMd 1⁄2 12  \nE910rEAME 3⁄4 12  \nE910rEAMF 1 10  \nE910rEAMG 11⁄4 10  \nE910rEAMH 11⁄2 10  \nE910rEAMJ 2 10  \nE910rEAMKiT All Sizes 5  \nCouplings  \n\n| CAT. No. | TrAdE SizE (iN.) | STd. CTN. |\n| --- | --- | --- |\n\nE910d 1⁄2 25  \nE910E 3⁄4 25  \nE910F 1 15  \nE910G 11⁄4 10  \nE910H 11⁄2 10  \nE910J 2 10  \n\n| CAT. No. | SizE (iN.) | Color | CAT. No. | SizE (iN.) | Color | CAT. No. | SizE (iN.) | Color | STd. CTN. |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Hl-6Xr | 1⁄2 | Red | Hl-6XB | 1⁄2 | Blue | Hl-6XY | 1⁄2 | Yellow | 1 Bag of 50 |\n| Hl-10r | 3⁄4 | Red | Hl-10B | 3⁄4 | Blue | Hl-10Y | 3⁄4 | Yellow | 1 Bag of 50 |\n| Hl-13Ar | 1 | Red | Hl-13AB | 1 | Blue | Hl-13AY | 1 | Yellow | 1 Bag of 50 |\n| Hl-16r | 11⁄4 | Red | Hl-16B | 11⁄4 | Blue | Hl-16Y | 11⁄4 | Yellow | 1 Bag of 50 |\n| Hl-18r | 11⁄2 | Red | Hl-18B | 11⁄2 | Blue | Hl-18Y | 11⁄2 | Yellow | 1 Bag of 50 |\n| Hl-21r | 2 | Red | Hl-21B | 2 | Blue | Hl-21Y | 2 | Yellow | 1 Bag of 50 |\n\nUnited States  \nTel: 901.252.8000  \n800.816.7809  \nFax: 901.252.1354  \nTechnical Services  \nTel: 888.862.3289  \n[www.tnb.com](www.tnb.com)  \nElbows, Sweeps and Accessories  \nPVC Conduit Repair System Instructions  \nAlternative to Conduit Repairs:  \nPrior to concrete pour, measure and saw cut all conduit stub-ups to the thickness of the concrete pour. Insert plugs. Pour concrete flush to the conduit. When pour is complete, remove plugs and proceed with Step 3. This alternative method saves time/money by elimina","cbCaimVZnSWr47Pv","https://ap.wps.com/l/cbCaimVZnSWr47Pv","pdf",6233344,66,"English","# Carlon® PVC Elbows, Conduit & Fittings\n## Elbows, Sweeps and Accessories (E-454–E-481)\n## Conduit Bodies (E-482–E-487)\n## Switch and Junction Boxes (E-488–E-492)\n## Straps, Clamps and Accessories (E-493–E-496)\n## Spacers (E-497–E-502)\n## P&C Flex® Conduit and Fittings (E-503–E-507)\n## Carflex® Liquidtight Flexible Conduit and Fittings (E-508–E-515)\n## Technical Information (E-516–E-518)\n## PVC Conduit Repair System Instructions\n## Alternative to Conduit Repairs","[{\"question\":\"What problem does the Carlon® PVC Conduit Repair System solve?\",\"answer\":\"It reduces the time and money needed to repair broken PVC conduits in concrete slabs (stub-ups). The system is designed for faster repairs without extensive concrete removal and re-pouring.\"},{\"question\":\"How does the repair process work at a high level?\",\"answer\":\"Cut off the broken conduit, ream the inside diameter, and insert a coupling or adapter while maintaining the conduit’s inside diameter.\"},{\"question\":\"What are the key cementing instructions for installing couplings and adapters?\",\"answer\":\"Clean the socket I.D. and spigot O.D., apply a uniform cement coat to the spigot end, push onto the socket bottom while rotating a quarter turn, and allow time to set before disturbing.\"}]","Carlon PVC Elbows, Conduit & Fittings - PVC Conduit Repair System - Job in Two Minutes | PDF",1790154471,166]