[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-656755-105":59,"doc-detail-656755-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","carbon-heating-film-installation-manual-safety-and-installation-requirements","Carbon Heating Film - Installation Manual - Safety And Installation Requirements","","Carbon Heating Film installation manual covering easy room heating for spaces when the film covers at least 70% of the floor. Includes key safety rules for electrical work by a licensed electrician, circuit and thermostat requirements, and strict installation restrictions such as no overlapping, no folding, no damp/wet-area use, and correct clearance from fireplaces and hot-water pipes. Provides required materials and tools lists, underfloor layout guidance, and system capacity calculations for selecting suitable wiring and thermostats, with example 120V and 220V configurations.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/carbon-heating-film-installation-manual-safety-and-installation-requirements/656755/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/carbon-heating-film-installation-manual-safety-and-installation-requirements/656755.png","ImageObject",300,407,{"name":92,"@type":93},"ahduag","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who must handle the electrical connections during installation?","Question",{"text":112,"@type":113},"All electrical connections must be made by a licensed electrician in accordance with national and local codes and standards.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the core do-not rules for placing the heating film?",{"text":117,"@type":113},"Do not fold or wrinkle the film, do not overlap it, do not walk on it unnecessarily, and never drop heavy or sharp objects on it.",{"name":119,"@type":110,"acceptedAnswer":120},"How is heating coverage area determined for effective room heating?",{"text":121,"@type":113},"The film can be used as the sole room heating source when it covers at least 70% of the floor, and it should be covered for at least 40% of the surface area to achieve comfortable heating.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},656755,1793001904,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":41},3985747870414,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Carbon Heating Film  \n• Easy to install.  \n• Can be used as a sole room heating source (when covers at least 70% of the floor) .  \n• Does not circulate pollutants, dust, dirt, allergens or dry air.  \n• May be installed on wall, ceiling, under laminate, engineered wood floors or tile.  \n• Brings soothing warmth to specific rooms or cold areas.  \n• Reduces energy up to 60% compared to forced air heating systems.  \n• Maintenance free, strong and durable.  \n• Complements your home heating system making rooms more comfortable.  \nRead through this entire manual before starting installation.  \n• All electrical connections must be made by a licensed electrician in accordance with national and local codes and standards.  \n• Always join multiple heating film lines in parallel ONLY (never in series) .  \n• Always make sure to check the heating film before, during, and after installation of the floor covering.  \n• Each thermostat requires a dedicated circuit at the breaker box.  \n• Must not be installed in damp or wet areas as defined by the National Electrical Code.  \n• Do not fold or wrinkle the heating film, walk on it unnecessarily, or drop heavy or sharp objects on it.  \n• Never overlap the heating film.  \n• Do not install electrical wires or pipes in the floor with the film.  \n• Be sure underlayment contains no cellulose.  \n• Install film only when room temperature is above freezing.  \n• Leave a 6-inch space between film and fireplaces, chimneys, or hot water pipes.  \n• Never use any type of insulation material on top of the heating film.  \n• Do not install the healing mats directly over a foil backed insulation material.  \n• When installing carpet a low tog underlay should be installed followed by a good quality hessian backed carpet.  \nFailure to follow these instructions may result in fire, electrical shock, property damage, personal injury, or death.  \nThe list of necessary materials before starting the installation of floor heating:  \n1. Infrared heating film standard width of 19 3/4”(50 cm), 31 ½”(80 cm) or 39 ¾”(1m);  \n2. Electrical wire. US standard:  \na) 12AWG, Stranded, THHN (to make connections from thermostat to heating film);  \nb) 12-2 NM cable (to make connection from thermostat to breaker);  \nFor Europe and other countries: recommended parameters of conductors: Copper-section-not less than 1.5 mm2;  \n3. Clamp Connectors and Mastic insulator.  \n4. Floor Insulation material. Using a heat insulator with a metallic coating is not recommended;  \n5. Plastic film thickness of not less than 0.1 mm, to use as vapor barrier (Blue Hawk 10-ft x 25-ft x 4-mil Clear Consumer Sheeting)  \n6. Scotch-tape;  \n7. Thermostat with temperature sensor.  \nList of required tools before starting the installation of floor heating:  \n1. Screwdriver;  \n2. Pliers;  \n3. Scissors;  \n4. Knife assembly;  \n5. Wire cutters;  \nInstalling Underfloor Heating Film.  \n1. Layout of electric underfloor heating systems  \nSketch a plan showing how the film will be installed. In drawing up a plan, should take into account that the organization of the main floor heating is necessary to cover at least 70% of the usable space. Do not install film under built-in cabinets, stationary design elements, appliances, in small closets (walk-ins are okay), or under other structures that do not have air circulation space under them. To arrange comfortable heating it must be covered for at least 40% of the surface aria.  \nLeave a space and padding around the perimeter of the room size from 4\"-8\"(10 to 20 cm) spacing between the strips of film-not more than 2”(5 cm) and no less than 1/2”(1cm)  \nNot allowed: overlapping film on a film  \nWhen planning the placement, should take into account that the heating film is cut into sections at designated places specially designed for cutting. The length of a single section is 9 7/8”(24.85 cm) .  \n2.Calculations capacity of the heating system, as well as the definition of the required number of thermostats and electrical power capabilities ","cbCaisjHpHO6No0c","https://ap.wps.com/l/cbCaisjHpHO6No0c","pdf",1141125,12,"English","# Installing Underfloor Heating Film\n## Layout Planning and Coverage Requirements\n## System Capacity Calculations and Thermostat Selection\n## Installation Steps and Handling Rules","[{\"question\":\"Who must handle the electrical connections during installation?\",\"answer\":\"All electrical connections must be made by a licensed electrician in accordance with national and local codes and standards.\"},{\"question\":\"What are the core do-not rules for placing the heating film?\",\"answer\":\"Do not fold or wrinkle the film, do not overlap it, do not walk on it unnecessarily, and never drop heavy or sharp objects on it.\"},{\"question\":\"How is heating coverage area determined for effective room heating?\",\"answer\":\"The film can be used as the sole room heating source when it covers at least 70% of the floor, and it should be covered for at least 40% of the surface area to achieve comfortable heating.\"}]","Carbon Heating Film - Installation Manual - Safety And Installation Requirements | PDF",1792970742]