[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-405479-105":59,"doc-detail-405479-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","capillary-isoelectric-focusing-of-proteins-and-peptides-using-an-in-line-cief-esi-interface-with-improved-ms-characteristics","Capillary Isoelectric Focusing of Proteins and Peptides Using an In-Line cIEF-ESI Interface with Improved MS Characteristics","","Intact protein analysis by mass spectrometry (MS) enables detailed characterization of protein complexity and supports “top-down” proteomics by resolving proteoforms and their post-translational modifications (PTMs). Online coupling of capillary isoelectric focusing (cIEF) with electrospray ionization offers high-resolution separation of proteoforms at the molecular level, yet ampholyte concentration conflicts with MS performance, causing reduced sensitivity and instrument contamination. An improved in-line cIEF-ESI-MS interface reduces (desalts) amino acid ampholytes between cIEF and electrospray. Proof-of-principle results show >90% increased electropherogram area, high reproducibility for cytochrome C, myoglobin, and α-casein proteoform standards, and no compromise of cIEF pH gradient linearity (R2=0.99), while BSA tryptic peptides achieve baseline resolution with 0.02 pI unit differences.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/capillary-isoelectric-focusing-of-proteins-and-peptides-using-an-in-line-cief-esi-interface-with-improved-ms-characteristics/405479/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/capillary-isoelectric-focusing-of-proteins-and-peptides-using-an-in-line-cief-esi-interface-with-improved-ms-characteristics/405479.png","ImageObject",300,407,{"name":92,"@type":93},"Himbo","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-29","2026-09-28",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is MS detection challenging when coupled with capillary isoelectric focusing (cIEF)?","Question",{"text":112,"@type":113},"Ampholytes are required to establish and maintain the cIEF pH gradient, which suppresses MS ionization and contaminates the mass spectrometer. This reduces sensitivity and robustness of cIEF-MS.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What improvement does the paper’s in-line cIEF-ESI-MS interface provide?",{"text":117,"@type":113},"The interface reduces (desalts) amino acid ampholytes in-line after cIEF and before electrospray ionization. This mitigates ampholyte suppression and contamination problems.",{"name":119,"@type":110,"acceptedAnswer":120},"What performance results are reported to validate the improved interface?",{"text":121,"@type":113},"Interface-based proof-of-principle experiments show a >90% increase in electropherogram area versus without the interface, high reproducibility for multiple protein standards’ proteoforms, and strong linearity of the cIEF pH gradient (R2=0.99). It also enables baseline peptide resolution with BSA showing detection of small pI differences.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},405479,1790742442,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":19,"preview_urls":145},687197100911,"https://ap-avatar.wpscdn.com/avatar/a000239b6f1da00475?x-image-process=image/resize,m_fixed,w_180,h_180&k=1785132997149421697","This article is licensed under CC-BY-NC-ND 4.0  \n[pubs.acs.org/ac](pubs.acs.org/ac)  Article   \nCapillary Isoelectric Focusing of Proteins and Peptides Using an InLine cIEF-ESI Interface with Improved MS Characteristics  \nCaitlin M. Kerr, Olivia L. Schneider, Shane Tichy, Bonnie Jaskowski Huge, and Matthew M. Champion *  \n Cite This: Anal. Chem. 2025, 97, 649−657  \nRead Online  \n\n|  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| ACCESS   | Metrics & More |  |  Article Recommendations |  | *sı Supporting Information |\n\nABSTRACT: Intact protein analysis using mass spectrometry (MS) is an important technique to characterize and provide a comprehensive overview of protein complexity. It is also the basis of “top-down” approaches in proteomics to describe the proteoforms of single protein’s post-translational modifications (PTMs). MS-based analysis of intact proteins benefits from high-resolution separations prior to electrospray ionization. Capillary isoelectric focusing (cIEF) is a high-resolution separation for proteins and peptides which is capable of separating proteoforms. MS detection coupled to cIEF can separate, detect, and characterize proteoforms at the molecular level. However, cIEF with MS detection is a compromised process. The concentration of ampholytes required for cIEF is mutually exclusive with mass spectrometer contam  \nination. We have improved an online cIEF-ESI-MS interface to reduce (desalt) amino acid ampholytes in-line after cIEF and prior to electrospray ionization. In proof of principle experiments, >90% increase in area under the curve of the electropherograms was observed with the interface compared to without the interface. Protein standards including proteoforms of cytochrome C, myoglobin, and α-casein were separated and resolved with high reproducibility. The interface did not compromise the linearity of the cIEF pH gradient separations, achieving a high linearity with a R2 of 0.99. In addition, a tryptic digest of BSA demonstrates baseline resolution of peptides with as little as 0.02 pI unit difference and a full width at half-maximum average of 7.1 s.  \n■ INTRODUCTION  \nMass spectrometry (MS) detection of intact proteins is an ideal method for identification and quantification of protein forms, or proteoforms. 1,2 Proteoforms, which encompass genetic variations, alternative splicing, and post-translational modifications (PTMs), can lead to diverse protein functions.3−9 Understanding vital biological processes and disease mechanisms necessitates proteome characterization at proteoform-specific resolution.  \nTraditionally, liquid chromatography (LC) and SDS-PAGE have been used for proteoform separation and identification due to their ability to separate complex intact protein mixtures.1,2, 10 Reverse-phase liquid chromatography however has limited capacity to resolve proteoforms with similar chemical composition, particularly for protein and peptide isoforms.1 SDS-PAGE is difficult to automate, and downstream processing is tedious.  \nCapillary zone electrophoresis (CZE) is an electrophoretic technique that separates analytes based on their size-to-charge ratio. 11−16 This enables higher resolution proteolytic separations in shorter time frames than LC and is readily interfaced to mass-spectrometric analysis.16, 17 However, it is constrained by low volumetric loading capacity (\u003C1% of capillary volume) and narrow separation windows.18, 19 Although recent efforts have improved the sample loading capacity in CZE it remains  \nan issue.20−23 Furthermore, CZE has limited resolution for individual charge variants of macromolecules like proteins.18,24,25 As such, it predominantly finds utility in cases where analysis is not concentration limited.26  \nCapillary isoelectric focusing (cIEF) is an alternative approach that uses the entire separation volume of the capillary and operates orthogonally to CZE and reverse-phase, relying on the electrophoretic separation of amphoteric molecules based on the","cbCainYS3Z0dbAPH","https://ap.wps.com/l/cbCainYS3Z0dbAPH","pdf",3882047,"English","# Abstract\n# Introduction\n## Intact protein MS and proteoform resolution\n## Limits of LC/SDS-PAGE for isoform separation\n## Role and constraints of CZE\n## cIEF principles and high-resolution capability\n## Why cIEF-MS is compromised and contamination challenges","[{\"question\":\"Why is MS detection challenging when coupled with capillary isoelectric focusing (cIEF)?\",\"answer\":\"Ampholytes are required to establish and maintain the cIEF pH gradient, which suppresses MS ionization and contaminates the mass spectrometer. This reduces sensitivity and robustness of cIEF-MS.\"},{\"question\":\"What improvement does the paper’s in-line cIEF-ESI-MS interface provide?\",\"answer\":\"The interface reduces (desalts) amino acid ampholytes in-line after cIEF and before electrospray ionization. This mitigates ampholyte suppression and contamination problems.\"},{\"question\":\"What performance results are reported to validate the improved interface?\",\"answer\":\"Interface-based proof-of-principle experiments show a \\u003e90% increase in electropherogram area versus without the interface, high reproducibility for multiple protein standards’ proteoforms, and strong linearity of the cIEF pH gradient (R2=0.99). It also enables baseline peptide resolution with BSA showing detection of small pI differences.\"}]","Capillary Isoelectric Focusing of Proteins and Peptides Using an In-Line cIEF-ESI Interface with Improved MS Characteristics | PDF",1790560245,23,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6b2b5f95150dc76dd3ac81c8ced1edbe.webp",983,1296,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/0f5f4ae4f933098e2f84382c583ece3c.webp",982,1295,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/fa35d95513d26bf99c8da131816c87f2.webp",981,1293,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3247cf14263268e99e199802398a2d6a.webp",980,1292]