[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-665210-105":59,"doc-detail-665210-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","cantilever-structure-drawing-1-of-3-plan-view","CANTILEVER STRUCTURE - DRAWING 1 OF 3 - PLAN VIEW","","Plan view notes for an ITS cantilever structure drawing set (standard drawing No 1581) specifying construction and safety requirements for ladder, fall/rest systems, and minimum configurations. The document defines installation constraints such as using trained personnel, double lanyard, full body harness, and signage fixed to the ladder. Serviceability, load combinations, maintenance platform requirements, and fall arrest system details are to align with TMR design criteria for bridges and other structures, with standard drafting notes referencing TMR structural drafting standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/cantilever-structure-drawing-1-of-3-plan-view/665210/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/cantilever-structure-drawing-1-of-3-plan-view/665210.png","ImageObject",300,407,{"name":92,"@type":93},"gewufjwa","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to use the ladder and fall/rest system described in the plan view notes?","Question",{"text":112,"@type":113},"The notes specify that the ladder must be used only by trained personnel having approved fall or rest system.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the minimum requirement for the fall or rest system?",{"text":117,"@type":113},"The minimum fall or rest system requirement is double lanyard and a full body harness.",{"name":119,"@type":110,"acceptedAnswer":120},"Which standards are referenced for serviceability, load combinations, and maintenance platform requirements?",{"text":121,"@type":113},"The notes state that serviceability requirements, load combinations, maintenance platform requirements, and related items shall be in accordance with TMR \"Design Criteria for Bridges and Other Structures\" and that standard notes shall follow TMR \"Structural Drafting Standards\".","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},665210,1793293231,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":39},3985747882900,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","# PLAN VIEW\n\nNOTES:  \n1.Ladder to be used only by trained personnel havingapproved fall orrest system.  \n2.Minimum fall orrest system requirement is doublelanyard and full body horness.  \n3.Sign to be fixed to ladder indicating this requirement.serviceability requirements,load combinations,maintenance platform requirements,fall orrestersystem,Grantry protection barrier etc.shallbe inaccordance with TMR \"Design Criteria for Bridges andOther Structures\".  \n5.Standard notes shallbe in accordance with therelevont Notes from TMR \"Structural DraftingStandards\".  \n| Department of Transport and Main Roads   |  |  |  |  | ◎The State of Queenslond (Depotment  \u003Cbr>of Transport and Main Roods)2014  \u003Cbr>http://creodiveommonsaorg/  \u003Cbr>liences/by/3.0/u   |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| ITS -CANTILEVER   |  |  |  |  |  |  |  |  |  |\n| CANTILEVER STRUCTURE  \u003Cbr>DRAWING 1 OF3   |  |  |  |  |  |  |  |  |  |\n|  | A3   |  | Standard_Drawing No  \u003Cbr>1581   |  |  |  |  |  |  |\n|  | Not  \u003Cbr>scodle   |  |  |  |  |  |  |  |  |\n|  | A   |  |  |  |  | Dote   | 814   |  |  |\n\n9500 max  \nBracket for AdjustingRod(Refer drawing1581 drawing 3 of 3)SECTION  \nDETAILELEVATIONVIEW₄EASSEMBLED END VIEWSUPPORT STRUCTURE 2  \n| Department of Transport and Main Roads   |  |  |  |  | ①  \u003Cbr>◎The State of Queersland (Deportment  \u003Cbr>of Transport and Main Roods)2014  \u003Cbr>http://creodiveommonsaorg/  \u003Cbr>liences/by/3.0/u   |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| ITS -CANTILEVER   |  |  |  |  |  |  |  |  |  |\n| CANTILEVER STRUCTURE  \u003Cbr>DRAWING 2 OF3   |  |  |  |  |  |  |  |  |  |\n|  | A3   |  | Standard_Drawing No  \u003Cbr>1581  \u003Cbr>Date 8/14   |  |  |  |  |  |  |\n|  | Not  \u003Cbr>scodle   |  |  |  |  |  |  |  |  |\n|  | A   |  |  |  |  |  |  |  |  |\n\nLOWER CAGE HOOP  \nVIEW(  \nCLEVIS MOUNTING BRACKET米  \nADJUSTING ROD米  \nUPPER CAGE HOOP  \nCLEVIS BRACKET BACKING PLATE米  \n| 米The adjusting Rods and Mounting Brackets ore fixed to the rear of  \u003Cbr>the sign box.The sign box is attached to the cantilever support  \u003Cbr>structure by these rods and brackets at the locations as shown on  \u003Cbr>drawing 1581 drawing 2 of 3.   |\n| --- |\n\nCAGE GUARD  \nUPPER LADDER-GANTRY REAR  \n\n| Department of Transport and Main Roads   |  |  |  |  | ①  \u003Cbr>◎The State of Queersland (Deportment  \u003Cbr>of Transport and Main Roods)2014  \u003Cbr>http://creodiveommonsaorg/  \u003Cbr>lcences/by/3.0/ou   |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| ITS -CANTILEVER   |  |  |  |  |  |  |  |  |  |\n| CANTILEVER STRUCTURE  \u003Cbr>DRAWING 3 OF3   |  |  |  |  |  |  |  |  |  |\n|  | A3   |  | Standard_Drawing No  \u003Cbr>1581  \u003Cbr>Date 8/14   |  |  |  |  |  |  |\n|  | Not  \u003Cbr>scodle   |  |  |  |  |  |  |  |  |\n|  | A   |  |  |  |  |  |  |  |  |","cbCaia7jZDIUMVAu","https://ap.wps.com/l/cbCaia7jZDIUMVAu","pdf",614130,"English","# PLAN VIEW\n## Ladder and fall/rest system requirements\n## Serviceability, load combinations, and maintenance platform requirements\n## Reference standards (TMR)","[{\"question\":\"Who is allowed to use the ladder and fall/rest system described in the plan view notes?\",\"answer\":\"The notes specify that the ladder must be used only by trained personnel having approved fall or rest system.\"},{\"question\":\"What is the minimum requirement for the fall or rest system?\",\"answer\":\"The minimum fall or rest system requirement is double lanyard and a full body harness.\"},{\"question\":\"Which standards are referenced for serviceability, load combinations, and maintenance platform requirements?\",\"answer\":\"The notes state that serviceability requirements, load combinations, maintenance platform requirements, and related items shall be in accordance with TMR \\\"Design Criteria for Bridges and Other Structures\\\" and that standard notes shall follow TMR \\\"Structural Drafting Standards\\\".\"}]","CANTILEVER STRUCTURE - DRAWING 1 OF 3 - PLAN VIEW | PDF"]