[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-645991-105":59,"doc-detail-645991-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","cannon-digital-paddle-viscometer-dpv-instruction-operation-manual","CANNON® Digital Paddle Viscometer (DPV) Instruction & Operation Manual","","Manual for the CANNON® Digital Paddle Viscometer (DPV) covering installation, key characteristics, and operational procedures. Describes how the DPV measures viscosity across materials such as asphalt emulsions, residual oils, slurries, paints, marine fuels, and similar samples within specified ranges of temperature and viscosity. Explains instrument construction, keypad-based setup and testing, continuous digital display updates, and serial output of test data. Includes safety features like overheat thermostat protection and RTD cutoff detection.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/cannon-digital-paddle-viscometer-dpv-instruction-operation-manual/645991/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/cannon-digital-paddle-viscometer-dpv-instruction-operation-manual/645991.png","ImageObject",300,407,{"name":92,"@type":93},"4398046744996","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-10","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What does the CANNON® DPV measure and what range is covered?","Question",{"text":113,"@type":114},"The DPV is designed to measure viscosity of materials such as asphalt emulsions, residual oils, slurries, paints, and marine fuels between 30 and 30,000 cP (mPa·s) at controlled temperatures (40 °C, 50 °C, 80 °C, and 100 °C).","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What safety protections does the DPV include?",{"text":118,"@type":114},"Safety features include an overheat thermostat that removes power from the DPV heater when an over-temperature fault is detected, and RTD cutoff detection that cuts power to the heater block if the control RTD is disconnected.",{"name":120,"@type":111,"acceptedAnswer":121},"How are viscosity test results shown and output?",{"text":122,"@type":114},"Viscosity results are continuously updated on the digital display on the front panel. When the test is complete, test data is output to the 9-pin serial output port for (optional) printing.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},645991,1792744730,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":66,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":130,"read_time":144,"preview_page_count":4},4398046744996,"DPV  \nDigital Paddle Viscometer  \nOperation Manual  \n17.4995  \nCONTENTS  \ni  \n1  INTRODUCTION 1  \nOverview ............................................................................................................................ 1  \nSafety features .................................................................................................................... 2  \nOperator Safety ................................................................................................................. 2  \nDPV specifications ............................................................................................................. 3  \nCalibrating the DPV ........................................................................................................... 3  \n2  UNPACKING AND ASSEMBLY 5  \nUnpacking the DPV ............................................................................................................ 5  \nAssembly procedure ........................................................................................................... 5  \nAdjusting the stop collar ......................................................................................... 6  \n3  DPV OPERATION 9  \nApplying power .................................................................................................................. 9  \nCold Start ................................................................................................................ 9  \nWarm Start .............................................................................................................. 9  \nSelf-test sequence ............................................................................................................. 10  \nFront panel operations ...................................................................................................... 10  \nUsing the keypad .................................................................................................. 10  \nRunning a test ................................................................................................................... 12  \nCleaning the DPV ............................................................................................................. 15  \nMENU options .................................................................................................................. 15  \nKeypad Control Options ................................................................................................... 16  \n4  MODEL DPV PROBLEM ANALYSIS 19  \n5 WARRANTY/RETURN INFORMATION 21  \nProducts limited warranty ................................................................................................. 21  \nReagent and chemical warranty ........................................................................................ 21  \nReturning a product to CANNON® .................................................................................. 22  \nCANNON® Digital Paddle Viscometer (DPV) Instruction & Operation Manual  \nCANNON® Instrument Company  \n2139 High Tech Road • State College, PA 16803 • USA  \nii  \nThis page intentionally left blank.  \nCANNON® Digital Paddle Viscometer (DPV) Instruction & Operation Manual  \nCANNON® Instrument Company  \n2139 High Tech Road • State College, PA 16803 • USA  \n  INTRODUCTION   \n1  \nOverview  \nScope of the manual  \nDPV capabilities  \nInstrument operation  \nDPV description  \nDPV function  \nReading test results  \nThis manual is intended to provide information on the installation, characteristics and operation of the CANNON® Digital Paddle Viscometer.  \nThe CANNON® Digital Paddle Viscometer (DPV) is designed to measure viscosity of asphalt emulsions, residual oils, slurries, paints, marine fuels, and other similar materials between 30 and 30,000 cP (mPa·s) at temperatures of 40 °C, 50 °C, 80 °C and 100 °C. The Digital Paddle Viscometer can also be used for other applications consistent with its temperature control and viscosity measurement capabi","cbCaibcvFaIPpPmx","https://ap.wps.com/l/cbCaibcvFaIPpPmx","pdf",1602442,28,"English","# INTRODUCTION\n## Overview\n## Safety features\n## Operator Safety\n# UNPACKING AND ASSEMBLY\n## Unpacking the DPV\n## Assembly procedure\n## Adjusting the stop collar\n# DPV OPERATION\n## Applying power\n## Cold Start\n## Warm Start\n## Self-test sequence\n## Front panel operations\n## Using the keypad\n## Running a test\n## Cleaning the DPV\n## MENU options\n## Keypad Control Options\n# MODEL DPV PROBLEM ANALYSIS\n# WARRANTY/RETURN INFORMATION","[{\"question\":\"What does the CANNON® DPV measure and what range is covered?\",\"answer\":\"The DPV is designed to measure viscosity of materials such as asphalt emulsions, residual oils, slurries, paints, and marine fuels between 30 and 30,000 cP (mPa·s) at controlled temperatures (40 °C, 50 °C, 80 °C, and 100 °C).\"},{\"question\":\"What safety protections does the DPV include?\",\"answer\":\"Safety features include an overheat thermostat that removes power from the DPV heater when an over-temperature fault is detected, and RTD cutoff detection that cuts power to the heater block if the control RTD is disconnected.\"},{\"question\":\"How are viscosity test results shown and output?\",\"answer\":\"Viscosity results are continuously updated on the digital display on the front panel. When the test is complete, test data is output to the 9-pin serial output port for (optional) printing.\"}]","CANNON® Digital Paddle Viscometer (DPV) Instruction & Operation Manual | PDF",71]