[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-398524-105":59,"doc-detail-398524-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","calibration-of-tsis-high-concentration-nanoparticle-emissions-tester-application-note-npet-002-rev-a-2018","CALIBRATION OF TSI’S HIGH-CONCENTRATION NANOPARTICLE EMISSIONS TESTER APPLICATION NOTE NPET-002 - Rev A - 2018","","TSI’s High-Concentration NPET model 3795-HC enables accurate field measurements of nanoparticle emissions from tailpipes, engines, and other combustion processes by diluting raw gas and removing volatile compounds to determine total solid particle number concentration. The application note summarizes calibration that verifies flow accuracy, zero false counts, detector and particle-size performance, and volatile particle remover efficiency. It describes detector checkout, flow calibration, detector calibration with soot challenges, system counting efficiency checks, and VPR efficiency confirmation, including example performance criteria.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/calibration-of-tsis-high-concentration-nanoparticle-emissions-tester-application-note-npet-002-rev-a-2018/398524/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/calibration-of-tsis-high-concentration-nanoparticle-emissions-tester-application-note-npet-002-rev-a-2018/398524.png","ImageObject",300,407,{"name":92,"@type":93},"Ivy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-25","2026-09-27",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",27,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the purpose of the HC-NPET in measuring nanoparticle emissions?","Question",{"text":113,"@type":114},"The HC-NPET dilutes raw exhaust gas and removes volatile compounds so it can measure total solid particle number concentration from tailpipes, engines, and combustion processes.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What are the main steps in the HC-NPET calibration process?",{"text":118,"@type":114},"Calibration includes detector subassembly checkout, flow calibration, zero count verification, detector calibration against a standard counter, system efficiency checks at specific particle sizes, and VPR efficiency measurement.",{"name":120,"@type":111,"acceptedAnswer":121},"What criteria are used to verify detector calibration and false counts?",{"text":122,"@type":114},"Zero count requires the instrument to average less than 0.5 #/cm3 false counts over a one-hour period, and detector calibration requires that at least 90% of challenged particles are at or above 23 nm.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},398524,1790793311,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":24,"preview_page_count":14,"preview_urls":145},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","CALIBRATION OF TSI’S  \nHIGH-CONCENTRATION  \nNANOPARTICLE EMISSIONS TESTER  \nAPPLICATION NOTE NPET-002 (A4)(8/9/2018) REV A  \nWhat does the HC-NPET do?  \nTSI’s High-Concentration NPET, model 3795-HC, allows you to make accurate field measurements of nanoparticle emissions from tailpipes, engines, or any combustion process (waste incinerators, power generators, ship engines, etc.) . It dilutes the raw gas and removes volatile compounds to measure total solid particle number concentration. The HC-NPET user-friendly software offers user-defined test cyclesand continuous measurements.  \nHow is the HC-NPET calibrated? Overview  \nThe HC-NPET calibration procedure is summarized in Figure 1. Briefly, the calibration procedure confirms the accuracy of flows within the instrument, and confirms its efficiency of removing volatile compounds and of counting solid particles.  \nThese steps are described in greater detail below.  \nCalibration Process Description  \n1. Detector subassembly checkout: for this initial step, the detector (CPC) within the HC-NPET is isolated from the rest ofthe instrument. The CPC is checked for leaks, its flows are set, and its optics are aligned. Once this is accomplished, the CPC is fully reconnected to the rest ofthe HC-NPET.  \n2. Flow calibration: flows within the entire instrument are calibrated. Flows measured indifferent places have different acceptable accuracies (±5% or 10%), but usually accuracy within 2% is achieved.  \n1 Detector sub-assembly checkout  \n2 Flow calibration  \n3 Zero count  \n4 Detector calibration  \n 5 System e􀀄ciency  \n6  \nVolatile particle remover (VPR) e􀀄ciency  \nFigure 1: Step-by-step calibration procedure for HC-NPET.  \n3. Zero count: in order to ensure the unit does not experience a problematic level of false counts, a zero-check filter is attached to the instrument inlet, and data is logged for a multi-hour period. In order to pass this step, a 3795-HC must average \u003C 0.5 \\#/ cm3 of false counts over a one-hour period.  \n4. Detector calibration: this step ensures that the instrument’s measured particle concentrations are accurate when compared to a standard particle counter. The instruments are challenged in parallel with a polydisperse soot aerosol; see Figure 2. At least 90% of the particles in this challenge must beat or above 23 nm in size for the test to proceed.  \n5. System efficiency: The goal of this step is to determine the counting efficiency of the HC-NPETat several specific particle sizes. The instruments are challenged in parallel with classified (i.e.‘size-selected’) soot particles. The concentrations measured by the two units are compared to ensure that the ratio meets TSI criteria; see Figure 3.  \n6. VPR efficiency: when an HC-NPET is sent through service at TSI, the successful removal of volatile aerosol by the catalytic stripper is measured and confirmed. Removal of emery oil aerosol exceeds 99%, while removal of tetracontane aerosol is very close to 100% .  \n\n| dN/d logDp (\\#/cm3) | 4.0E+05\u003Cbr>3.0E+05\u003Cbr>2.0E+05\u003Cbr>1.0E+05\u003Cbr>0.0E+00 | |\n| --- | --- | --- |\n\nFigure 2: Size distribution of polydisperse soot used as a challenge aerosol in Step \\#4, Detector Calibration. 90% of the particles must be ≥ 23 nm in size; in this example, ~97% of particles are ≥ 23 nm.  \n\n| % Count ing Efficiency | 140\u003Cbr>120\u003Cbr>100\u003Cbr>80\u003Cbr>60\u003Cbr>40\u003Cbr>20\u003Cbr>0 |  HC-NPET limits ~~ ~~ HC-NPET counting efficienc y\u003Cbr>|\n| --- | --- | --- |\n| 0 50 100 150 200\u003Cbr>Particle Diameter (nm) |  |  |\n\nFigure 3: HC-NPET counting efficiency curve and limits.  \nContact Us  \nFor more information on TSI’s HC-NPET, please don’t hesitate to contact TSI using the contact information below. Alternatively, [you may email](you may email particle@tsi.com)[ ](you may email particle@tsi.com)[particle@tsi.com](you may email particle@tsi.com), or contact your local sales representative.  \n_____________________  \nTSI, TSI logo, and Aerosol Instrument Manager are registered trademarks ofTSI Incorporated.  \nUNDERSTANDING","cbCaikWFoMyVoCw0","https://ap.wps.com/l/cbCaikWFoMyVoCw0","pdf",459843,"English","# What does the HC-NPET do?\n# How is the HC-NPET calibrated? Overview\n# Calibration Process Description\n## Detector subassembly checkout\n## Flow calibration\n## Zero count\n## Detector calibration\n## System efficiency\n## VPR efficiency\n# Contact Us","[{\"question\":\"What is the purpose of the HC-NPET in measuring nanoparticle emissions?\",\"answer\":\"The HC-NPET dilutes raw exhaust gas and removes volatile compounds so it can measure total solid particle number concentration from tailpipes, engines, and combustion processes.\"},{\"question\":\"What are the main steps in the HC-NPET calibration process?\",\"answer\":\"Calibration includes detector subassembly checkout, flow calibration, zero count verification, detector calibration against a standard counter, system efficiency checks at specific particle sizes, and VPR efficiency measurement.\"},{\"question\":\"What criteria are used to verify detector calibration and false counts?\",\"answer\":\"Zero count requires the instrument to average less than 0.5 #/cm3 false counts over a one-hour period, and detector calibration requires that at least 90% of challenged particles are at or above 23 nm.\"}]","CALIBRATION OF TSI’S HIGH-CONCENTRATION NANOPARTICLE EMISSIONS TESTER APPLICATION NOTE NPET-002 - Rev A - 2018 | PDF",1790482821,[146,150],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/7e00493f1cd8af6e7f18c5953157f916.webp",983,1390,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c4d90bb0adb89e4b5d9764a67927558c.webp",982,1388]