[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-502101-105":59,"doc-detail-502101-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","calibration-certificate-ccat-scientific-digital-thermometer-t-68999","Calibration Certificate - CCAT Scientific - Digital Thermometer T-68999","","This formal calibration certificate documents the testing and verification of an Omega Digital Thermometer (Model 869, Platinum RID, System ID: T-68999) performed at CCAT Scientific. The document details calibration results across a temperature range of -79.7℃ to 20.0℃, comparing true values against instrument readings and providing necessary correction factors. It confirms that measurements are traceable to national standards in New Zealand or Australia, conducted at an ambient temperature of 22℃±2℃ using ITS-90 temperature scales, ensuring high accuracy and reliability for temperature-sensitive applications.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/calibration-certificate-ccat-scientific-digital-thermometer-t-68999/502101/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/calibration-certificate-ccat-scientific-digital-thermometer-t-68999/502101.png","ImageObject",300,407,{"name":92,"@type":93},"Well Done","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-03",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What was the primary purpose of the document?","Question",{"text":112,"@type":113},"The document serves as an official calibration certificate for an Omega Digital Thermometer (T-68999) to verify its measurement accuracy against national standards.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the measurement uncertainty reported for this calibration?",{"text":117,"@type":113},"The measurement uncertainties are reported at a 95% confidence level with a coverage factor of k=2.0, with values ranging from ±0.1℃ to ±0.2℃ depending on the calibration point.",{"name":119,"@type":110,"acceptedAnswer":120},"Were any adjustments made to the device during the calibration process?",{"text":121,"@type":113},"No, the calibration results indicate that no adjustments were made to the device, and the instrument functioned as expected without abnormal performance.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},502101,1792172881,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":81,"preview_page_count":8,"preview_urls":144},5909892210082,"https://ap-avatar.wpscdn.com/avatar/56001069da27c9f41e8?x-image-process=image/resize,m_fixed,w_180,h_180&k=1789614185077863061","Company:  \nCCAT Scientific  \n711 Werenui Road  \nRD1  \nSilverdale 0994  \nComments  \nThe battery was replaced prior to calibration.  \nThe reference devices used were s/n 3414,351773/1 and 35278/1.  \nThis certificate may only be reproduced in full.  \nSignatory  \nRhys Blair  \nCalibration Certificate  \nMeasurement results are traceable to the New Zealand or Australian national standards  \nInstrument/System ID:T-68999  \nType:Digital Thermometer  \nBrand:Omega  \nModel:869,Platinum RID s/n T-68999  \nUse:Temperature checks  \n# CALIBRATION RESULTS\n\n\n| True Value(℃)   | Instrument Reads(℃)   | Correction(℃)  \u003Cbr>(as found)   | Adjustment    | Instrument Reads(℃)   | Correction(℃)  \u003Cbr>(as leff)   | Uncertainty(℃)   |\n| --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |\n| -79.7   | -78.8   | -0.9   | No   |  |  | ±0.2   |\n| -20.0   | -19.4   | -0.6   | No   |  |  | ±0.1   |\n| 5.0   | 5.2   | -0.2   | No   |  |  | ±0.1   |\n| 20.0   | 20.1   | -0.1   | No   |  |  | ±0.1   |\n\nReadings of the instrument being calibrated were compared to one or more of the laboratory's reference thermometers in liquid calibration bathsusing procedures that are documented in sections 5.01 and 5.09 of the Laboratory Procedures Manual.  \nThe immersion depth of the probes during the calibration was 100 mm and the ambient temperature was 22℃±2℃.The temperature scale used is ITS-90.  \nThe instrument functioned in a manner that was typical for this type of instrument.There wasno evidence of abnormal performance during the timethat the instrument was inspected and calibrated.The calibration results relate to the instrument as tested.This calibration was performed in the laboratory.  \nThe measurement uncertainties of the instrument/system tested at the above calibration points and using the corrections in the table are at the 95%confidence level with coverage factor k=2.0.  \nCert No.39643  \nTest Date:13th Mar 2025  \nTested By:Rachelle Wilson  \nResolution:0.1℃","cbCailLFdLLGJjoM","https://ap.wps.com/l/cbCailLFdLLGJjoM","pdf",155495,"English","# Calibration Results\n## Measurement Procedures and Conditions","[{\"question\":\"What was the primary purpose of the document?\",\"answer\":\"The document serves as an official calibration certificate for an Omega Digital Thermometer (T-68999) to verify its measurement accuracy against national standards.\"},{\"question\":\"What is the measurement uncertainty reported for this calibration?\",\"answer\":\"The measurement uncertainties are reported at a 95% confidence level with a coverage factor of k=2.0, with values ranging from ±0.1℃ to ±0.2℃ depending on the calibration point.\"},{\"question\":\"Were any adjustments made to the device during the calibration process?\",\"answer\":\"No, the calibration results indicate that no adjustments were made to the device, and the instrument functioned as expected without abnormal performance.\"}]","Calibration Certificate - CCAT Scientific - Digital Thermometer T-68999 | PDF",1791029241,[145],{"page_no":8,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4acca781848048fc50dc674c9cb61f06.webp",983,1389]