[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-672079-105":59,"doc-detail-672079-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","c1200-n5c-generator-set-data-sheet","C1200 N5C - Generator set data sheet","","Generator set data sheet for model C1200 N5C, providing continuous 1200 kW-class performance parameters at 50 Hz. Specifications include natural gas fuel details (MI 62), NOx emissions levels, and LT/HT cooling system temperature targets. The sheet lists generator electrical output, heat rejected in LT and HT circuits, intake and exhaust airflow characteristics, engine coolant volumes and flow rates, and exhaust heat available. It also includes engine configuration (Cummins QSK60G, V16) and key efficiency figures (mechanical and electrical) across rated load levels.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/c1200-n5c-generator-set-data-sheet/672079/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/c1200-n5c-generator-set-data-sheet/672079.png","ImageObject",300,407,{"name":92,"@type":93},"Eliana","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-11-02",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the rated operating conditions for the C1200 N5C generator set?","Question",{"text":112,"@type":113},"The sheet specifies continuous operation at 50 Hz with a natural gas fuel type and includes performance breakouts at 100%, 90%, 75%, and 50% of rated load.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What cooling temperatures and flows are specified for LT and HT circuits?",{"text":117,"@type":113},"LT inlet temperature is specified as 40 °C, with HT water outlet temperature listed as 90 °C, and the table provides corresponding coolant volumes and flow rates for each load level. It also includes reference LT outlet temperature of 50 °C.",{"name":119,"@type":110,"acceptedAnswer":120},"What emissions performance targets are provided?",{"text":121,"@type":113},"NOx emissions dry ppm and NOx mg/Nm3 @ 5% O2 are provided, along with THC (wet) ppm and mg/Nm3, NMHC emissions, and CO emissions (dry ppm and mg/Nm3 @ 5% O2) across load levels.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},672079,1793585304,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},4398048949847,"https://ap-avatar.wpscdn.com/avatar/400002536579ef2da7f?_k=1778318612642679267","Generator set data sheet 1200 kW continuous  \nModel: C1200 N5C  \nFrequency: 50 Hz  \nFuel type: Natural gas MI 62 +  \nEmissions performance NOx: 250 Mg/Nm3 LT water inlet temperature: 40 °C (104 ° F) HT water outlet temperature: 90 °C (194 ° F)  \n\n| Measured sound performance data sheet: | N/A |\n| --- | --- |\n| Prototype test summary data: | N/A |\n| Remote radiator cooling outline: | A029U550 normal duty air filtration\u003Cbr>A029E093 heavy duty air filtration |\n\n\n| Fuel consumption (ISO3046/1) | See\u003Cbr>note | 100% of rated load | 90% of\u003Cbr>rated load | 75% of\u003Cbr>rated load | 50% of\u003Cbr>rated load |\n| --- | --- | --- | --- | --- | --- |\n| Fuel consumption (LHV) ISO3046/1, kW (MMBTU/hr) | 2,3,6,11 | 2947 (10 .06) | 2675 (9 . 14) | 2313 (7 .9) | - |\n| Mechanical efficiency ISO3046/1, percent | 2,3,6 | 41.9% | 41.6% | 40.2% | - |\n| Electrical efficiency ISO3046/1, percent | 2,3,6,11 | 40.7% | 40.4% | 38.9% | - |\n\nEngine  \n\n| Engine manufacturer | Cummins |\n| --- | --- |\n| Engine model | QSK60G |\n| Configuration | V16 |\n| Displacement, L ([cu.in](cu.in). ) | 60 (3671) |\n| Aspiration | Turbocharged (1) |\n| Gross engine power output, kWm (hp) | 1236 (1657) |\n| BMEP, bar (psi) | 16.5 (239 .25) |\n| Bore, mm (in. ) | 159 (6 .26) |\n| Stroke, mm (in. ) | 190 (7 .48) |\n| Rated speed, rpm | 1500 |\n| Piston speed, m/s (ft/min) | 9.5 (1870) |\n| Compression ratio | 13.7:1 |\n| Lube oil capacity, L (qt) | 380 (400) |\n| Overspeed limit, rpm | 1875 |\n| Full load lubricating oil consumption,\u003Cbr>g/kWe-hr (g/hp-hr) | 0.15 (0 . 11) |\n| Fuel |  |\n| Gas supply pressure to engine inlet, bar (psi)6 | 0.20 (2 .9) |\n| Minimum methane index | 62 |\n\n [power.cummins.com](power.cummins.com)  \n©2017 Cummins Inc. | NAD-5474-EN (08/17)  \nStarting system(s)  \n\n| Electric starter voltage, volts | 24 |\n| --- | --- |\n| Minimum battery capacity @ 40 °C (104 °F), AH | 450 |\n| Air starter pressure, barg (psig) | N/A |\n| Air starter flow Nm3/s (scfm) | N/A |\n| Genset dimensions (see note 1) |  |\n| Genset length, m (ft) | 5.12 (16 .8) |\n| Genset width, m (ft) | 2.23 (7 .30) |\n| Genset height, m (ft) | 2.77 (9 .08) |\n| Genset weight (wet), kg (lbs) | 15450 (33,990) |\n\n\n|  | See\u003Cbr>note | 100% of\u003Cbr>rated load | 90% of\u003Cbr>rated load | 75% of\u003Cbr>rated load | 50% of\u003Cbr>rated load |\n| --- | --- | --- | --- | --- | --- |\n| Energy data |  |  |  |  |  |\n| Continuous generator electrical output kWe @ 1.0 pf | 9,11 | 1200 | 1080 | 900 | - |\n| Total heat rejected in LT circuit, kW (MMBTU/h) | 4 | 98 (0 .34) | 86 (0 .30) | 70 (0 .24) | - |\n| Total heat rejected in HT circuit, kW (MMBTU/h) | 4 | 605 (2 .06) | 543 (1 .85) | 495 (1 .69) | - |\n| Unburnt, kW (MMBTU/h) | 12 | 92 (0 .32) | 84 (0 .29) | 61 (0 .21) | - |\n| Heat radiated to ambient, kW (MMBTU/h) | 12 | 189 (0 .64) | 172 (0 .59) | 149 (0 .51) | - |\n| Available exhaust heat to 105 °C, kW (MMBTU/h) | 4 | 737 (2 .51) | 686 (2 .34) | 561 (1 .91) | - |\n|  |  |  |  |  |  |\n| Intake air flow |  |  |  |  |  |\n| Intake air flow mass, kg/s (lb/hr) | 3 | 1.82 (14410) | 1.65 (13070) | 1.26 (9980) | - |\n| Intake air flow volume, m3/s @ 0 °C (scfm) | 3 | 1.41 (3150) | 1.28 (2860) | 0.97 (2170) | - |\n| Max air cleaner restriction below 35 °C, mm HG (in H2O) |  | 28 (15 .0) | - | - | - |\n| Max air cleaner restriction above 35 °C, mm HG (in H2O) |  | 14 (7 .3) | - | - | - |\n|  |  |  |  |  |  |\n| Exhaust air flow |  |  |  |  |  |\n| Exhaust gas flow mass, kg/s (lb/hr) | 3 | 1.88 (14890) | 1.71 (13540) | 1.30 (10300) | - |\n| Exhaust gas flow volume, m3/s (cfm) | 3 | 3.85 (8150) | 3.55 (7520) | 2.80 (5930) | - |\n| Exhaust temp after turbine, °C (° F) | 2,11 | 450 (841) | 459 (858) | 486 (907) | - |\n| Max exhaust system back pressure, mm HG (in H2O) | 11,13 | 28.0 (15 .0) | - | - | - |\n| Min exhaust system back pressure, mm HG (in H2O) | 11,13 | - | - | - | - |\n|  |  |  |  |  |  |\n| HT cooling circuit |  |  |  |  |  |\n| HT circuit engine coolant volume, l (gal) |  | 181 (48) | 181 (48) | 181 (48) | - |\n| HT coolant flow @ max ext restriction, m3/h (gal/mi","cbCaijgO9gwXgOsT","https://ap.wps.com/l/cbCaijgO9gwXgOsT","pdf",233199,"English","# Model and operating conditions\n## Fuel, emissions, and cooling targets\n# Performance and efficiency\n## Fuel and efficiencies by load\n# Engine specifications\n## Engine configuration and operating limits\n# Genset dimensions and starting system\n## Dimensions and electrical starter details\n# Energy and thermal data\n## Heat rejected and radiated heat\n# Airflow and exhaust parameters\n## Intake and exhaust flow and temperatures\n# Cooling circuits\n## HT circuit and LT circuit\n# Emissions\n## NOx, THC, NMHC, and CO values","[{\"question\":\"What are the rated operating conditions for the C1200 N5C generator set?\",\"answer\":\"The sheet specifies continuous operation at 50 Hz with a natural gas fuel type and includes performance breakouts at 100%, 90%, 75%, and 50% of rated load.\"},{\"question\":\"What cooling temperatures and flows are specified for LT and HT circuits?\",\"answer\":\"LT inlet temperature is specified as 40 °C, with HT water outlet temperature listed as 90 °C, and the table provides corresponding coolant volumes and flow rates for each load level. It also includes reference LT outlet temperature of 50 °C.\"},{\"question\":\"What emissions performance targets are provided?\",\"answer\":\"NOx emissions dry ppm and NOx mg/Nm3 @ 5% O2 are provided, along with THC (wet) ppm and mg/Nm3, NMHC emissions, and CO emissions (dry ppm and mg/Nm3 @ 5% O2) across load levels.\"}]","C1200 N5C - Generator set data sheet | PDF",13]