[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-201803-105":59,"doc-detail-201803-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","bx2lp-stratus-multi-deck-specification-sheet-issue-september-2018","BX2LP-STRATUS - Multi-Deck Specification Sheet - Issue September 2018","","BX2LP-STRATUS multi-deck specification sheet for September 2018, providing performance, refrigeration, and electrical data across multiple case lengths (4', 6', 8', 12'). The sheet lists total display area and cubic capacity, maximum shelf depth, discharge air velocity and temperature, thermal load estimates for canopy LED applications, and supplemental Btuh per ft. It also includes refrigeration settings for HFC and glycol (evaporator temperature, superheat, supply temperature, flow, charge estimates), defrost parameters, and 115V electrical fan and LED lighting amps/watts details, plus compliance notes and manufacturer contact information.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/bx2lp-stratus-multi-deck-specification-sheet-issue-september-2018/201803/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/bx2lp-stratus-multi-deck-specification-sheet-issue-september-2018/201803.png","ImageObject",300,407,{"name":92,"@type":93},"Paura","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-09-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What case lengths are covered in the BX2LP-STRATUS multi-deck specifications?","Question",{"text":113,"@type":114},"The specifications provide values for case lengths of 4’, 6’, 8’, and 12’.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What refrigeration parameters are listed for the HFC configuration?",{"text":118,"@type":114},"For HFC, the sheet lists evaporator temperature, superheat setpoint, and estimated refrigerant charge by case length.",{"name":120,"@type":111,"acceptedAnswer":121},"What defrost information is included in the off-cycle section?",{"text":122,"@type":114},"The off-cycle defrost section includes defrosts per day, failsafe duration, termination temperature, and drip time, with notes for conditions above 75°F and 55% RH.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},201803,1788538848,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":130,"read_time":24,"preview_page_count":4},13056712833777,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","ISSUE DATE: SEPTEMBER 2018  \nBX2LP-STRATUS  \nMULTI-DECK SPECIFICATION SHEET  \nCase Length (ft)  \nAPPLICATIONS  \n\n| General Case Data | 4’ | 6’ | 8’ | 12’ |\n| --- | --- | --- | --- | --- |\n| Total Display Area (ft2) | 11.53 | 17.31 | 23.06 | 34.62 |\n| Cubic Capacity (ft3) | 16.23 | 24.37 | 32.46 | 48.74 |\n| Max Shelf Depth (in) [Top/Bottom] | 12/22 | 12/22 | 12/22 | 12/22 |\n| Weight (lb) | - | - | - | - |\n| Refrigeration Data (General) |  |  |  |  |\n| Discharge Air Velocity (fpm) | 150-200 | 150-200 | 150-200 | 150-200 |\n| Fan Speed (rpm) | 900 | 900 | 900 | 900 |\n| Discharge Air Temp (˚F) | 31 | 31 | 31 | 31 |\n| Conventional Thermal Load, Single (Btuh) one row of canopy LED | 2761 | 4142 | 5523 | 8284 |\n| Parallel Thermal Load, Single (Btuh) one row of canopy LED | 2560 | 3840 | 5120 | 7680 |\n| Additional Btuh per ft LED-Canopy / Shelf & Nose | 13 / 11 | 13 / 11 | 13 / 11 | 13 / 11 |\n| Refrigeration Data (HFC) |  |  |  |  |\n| Evaporator Temperature (˚F) | 26 | 26 | 26 | 26 |\n| Superheat Setpoint (˚F) | 6-8 | 6-8 | 6-8 | 6-8 |\n| Estimated Refrigerant Charge (lbs) | 1.851 | 2.768 | 3.703 | 5.536 |\n| Refrigeration Data (Glycol) |  |  |  |  |\n| Supply Temperature (˚F) | 20 | 20 | 20 | 20 |\n| Flow (GPM) | QTE | QTE | QTE | QTE |\n| Fluid % | 35 | 35 | 35 | 35 |\n| Pressure Drop (PSID) | QTE | QTE | QTE | QTE |\n| Electrical Data (Amps/Watts) |  |  |  |  |\n| 115V/60Hz, 1 Phase |  |  |  |  |\n| Fans | 0.06 | 0.11 | 0.11 | 0.22 |\n| Canopy Lights (Per row) |  |  |  |  |\n| GE LED | 0.22 | 0.33 | 0.44 | 0.67 |\n| Shelf Lights (Per row) |  |  |  |  |\n| GE LED | 0.08 | 0.10 | 0.15 | 0.23 |\n\n| Defrost Data (off Cycle) |  |  |  |\n| --- | --- | --- | --- |\n| Defrosts per Day | Failsafe Duration (min)1 | Termination Temp (˚F) | Drip Time (min) |\n| 6 | 18 | 47 | 2 |\n\n1 At ASHRAE conditions. For conditions above 75°F, 55% RH, increase defrost time by 15 min. Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained that conditions do not exceed 75°F and 55% relative humidity. Heatcraft Worldwide Refrigeration, whose policy is one of continuous improvement, reserves the right to change at anytime specifications, designs, or prices without incurring obligation. DOE 2017 Compliant  \n5201 Transport Blvd Columbus, GA 31907  \nP: 800.866.5596 • F: 706.568.8990  \n[www. kysorwarren.com](www. kysorwarren.com)","cbCaiigzEWU4iXrh","https://ap.wps.com/l/cbCaiigzEWU4iXrh","pdf",286753,"English","# General Case Data\n## Refrigeration Data (General)\n## Refrigeration Data (HFC)\n## Refrigeration Data (Glycol)\n## Electrical Data (Amps/Watts)\n## Defrost Data (Off Cycle)","[{\"question\":\"What case lengths are covered in the BX2LP-STRATUS multi-deck specifications?\",\"answer\":\"The specifications provide values for case lengths of 4’, 6’, 8’, and 12’.\"},{\"question\":\"What refrigeration parameters are listed for the HFC configuration?\",\"answer\":\"For HFC, the sheet lists evaporator temperature, superheat setpoint, and estimated refrigerant charge by case length.\"},{\"question\":\"What defrost information is included in the off-cycle section?\",\"answer\":\"The off-cycle defrost section includes defrosts per day, failsafe duration, termination temperature, and drip time, with notes for conditions above 75°F and 55% RH.\"}]","BX2LP-STRATUS - Multi-Deck Specification Sheet - Issue September 2018 | PDF"]