[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-649112-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-649112-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","building-regulations-and-building-permits-building-permit-application-samples","Building Regulations and Building Permits - Building Permit Application Samples","","Building permit drawing samples and submission requirements focused on site plan, elevations, floor plan, and cross sections. The text specifies scales in both imperial and metric, required contents such as room layout and dimensions, plumbing fixtures, exterior finish details, structural elements like joist and beam sizes, and special sunddeck railing and construction notes. It also lists site and lot coverage information, statutory right of way, and detailed cross-section build-up layers including insulation, vapour barrier, sheathing, slab and drainage components.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/building-regulations-and-building-permits-building-permit-application-samples/649112/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/building-regulations-and-building-permits-building-permit-application-samples/649112.png","ImageObject",300,407,{"name":42,"@type":43},"Anna Hans","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-23",true,{"@type":52,"interactionType":53,"userInteractionCount":33},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What additional information is required for a building permit application besides drawings?","Question",{"text":62,"@type":63},"The text requires additional information including site coverage (s.c.), land covered by buildings, and area of the lot.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What scale standards must elevations and floor plans follow?",{"text":67,"@type":63},"Elevations must be drawn at a scale not less than 1/8\" to 1' (1:100 Metric), and floor plans at 1/4\" to 1'(1:50 Metric).",{"name":69,"@type":60,"acceptedAnswer":70},"Which elements must the floor plan show?",{"text":71,"@type":63},"The floor plan must show all rooms with size and use, all plumbing fixtures, all outside dimensions, structural details such as joist size and spacing and beam/column sizes, and the total area of the building.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},649112,1792797363,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":33,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":96},5909892332657,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Building Regulations and Building Permits   \nSamples of drawings required for Building Permit Application  \nAdditional information required includes site coverage (s.c.) s.c. = land covered by buildings  \narea of lot  \n26.5 m (87'0\")  \n43.89 m (144'0\")  \n| \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>Proposed Residence Driveway\u003Cbr>\u003Cbr>Existing Accessory Bldg. 12'x18'\u003Cbr>\u003Cbr>3.3 m (11'0\")\u003Cbr>15.03 m\u003Cbr>(49'4\")\u003Cbr>8 m (26'3\")\u003Cbr>m (19'6\")\u003Cbr>5.9\u003Cbr>m (19'0\")\u003Cbr>5.7\u003Cbr>m\") |  |\n| --- | --- |\n| | \u003Cbr>3 m (9'10\") Statutory Right of Way\u003Cbr>4.8\u003Cbr>(16'0 |\n\n43.89 m (144'0\")  \n26.5 m (87'0\") Road  \nSITE PLAN  \nSite Plan Scale=  \nLot \\#  Plan \\#   \nDist. Lot \\#  Land District    \nLot Coverage:    \nLot Area =   Proposed Coverage Lot Coverage Note: Setbacks are to gutters  \nELEVATIONS  \n• scale not less than 1/8\" to 1' (1:100 Metric)  \n• full views of front, rear, and both sides of buildings including additions  \n• exterior finish details (materials used)  \n• sundeck additions require railing details (height and type of construction)  \n Building in the RDN   What you should know   \nFLOOR PLAN  \n• scale 1/4\" to 1'(1:50 Metric)  \n• show all rooms, size and use of each room  \n• all plumbing fixtures  \n• all outside dimensions  \n• structural details e.e. joist size and spacing, size of beams and columns  \n• total area of building  \n 24'    \n  13'6\"    \n 10'6\"  \n 42'   \n|  | \u003Cbr>Rec Room 13'x19'\u003Cbr>3-2\"x12’s DF\u003Cbr>Foyer 10'x12'\u003Cbr>| \u003Cbr>3-2\"x10’s DF\u003Cbr>|\n| --- | --- | --- |\n\n2\"x10’s @16\"OC  \n2\"x10’s @16\"OC  \n 19'6\" ~~ ~~ 12'6\" 10'0\"  \nCROSS SECTION  \n• scale not less than 1/4\" to 1'  \n(1:50 Metric)  \n• showing method of construction  \n• showing structural and other pertinent details  \nCSA APPROVED DUROID  \nSUNDECK (6'x12') MAX. SPACING BETWEEN VERTICAL MEMBERS 4\"  \n42\" MIN. HEIGHT  \n2-2\"x8\" No. 2 DOUGLAS FIR BEAMS  \n6\"x6\" POST  \nSADDLES ON  \n8\" CONC. PIERS 26\"x26\"x6\"FOOTINGS  \n2x10 JOISTS @16\"OC  \nSHINGLES OVER 1/2\" OSB SHEATHING – CSA APPROVED TRUSSES  \n2-2\"x10’s LINTEL  \n2\"x4\" STUDS @16\"OC  \n– 1/2\" GYPROC BOTH SIDES  \nINTERIOR FINISH R-20 INSULATION  \n– 6 MI UV VAPOUR BARRIER  \n– 1/2\" GYPSUM BOARD  \nFINISHED FLOORING  \n3/4\" OSB OVER 2\"x10\" JOISTS @16\"OC (GLUED)  \nCROSS BRIDGING  \n@7\"OC MAX.  \n4\" CONC. SLAB  \n6 MIL V. B  \n6\" COMPACTED GRAVEL  \nFIGS. MIN. 18\" BELOW GRADE TO SOLID BEARING  \nCONTINUOUS VENTED ALUMINUM SOFFIT  \n– 2\"x6\" STUDS @16\"OC  \n– 7/16\" PLYWOOD SHEATING  \n– BUILDING PAPER  \n– CEDAR SIDING  \n– 1/2\" ANCHOR BOLTS 8'OC MAX.  \n– SILL GASKET  \n– 8\" CONC. WALL  \n– 16\"x8\" STRIP FOOTING  \n4\" PERIMETER DRAIN TILE, 6\" DRAIN ROCK COVER","cbCaijjzr3MSyiZj","https://ap.wps.com/l/cbCaijjzr3MSyiZj","pdf",76751,"English","# Samples of drawings required for Building Permit Application\n## Site plan and lot information\n## Elevations requirements\n## Floor plan requirements\n## Cross section and structural build-up details","[{\"question\":\"What additional information is required for a building permit application besides drawings?\",\"answer\":\"The text requires additional information including site coverage (s.c.), land covered by buildings, and area of the lot.\"},{\"question\":\"What scale standards must elevations and floor plans follow?\",\"answer\":\"Elevations must be drawn at a scale not less than 1/8\\\" to 1' (1:100 Metric), and floor plans at 1/4\\\" to 1'(1:50 Metric).\"},{\"question\":\"Which elements must the floor plan show?\",\"answer\":\"The floor plan must show all rooms with size and use, all plumbing fixtures, all outside dimensions, structural details such as joist size and spacing and beam/column sizes, and the total area of the building.\"}]","Building Regulations and Building Permits - Building Permit Application Samples | PDF"]