[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663421-105":59,"doc-detail-663421-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","buildblock-icf-installation-technical-manual","BUILDBLOCK ICF Installation & Technical Manual","","BUILDBLOCK Insulating Concrete Forms (ICF) Installation & Technical Manual provides guidance and safety expectations for installing BuildBlock building systems. It states that the current manual version must be used, recommends receiving proper training, and directs users to applicable building codes and local professionals. Product warnings address corrosion risks from ACQ-treated wood contacting metal components. The manual also includes trademark information, acknowledgments, and a limited product warranty defining coverage terms, notice requirements, and exclusions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/buildblock-icf-installation-technical-manual/663421/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/buildblock-icf-installation-technical-manual/663421.png","ImageObject",300,407,{"name":92,"@type":93},"404brain","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of this installation manual?","Question",{"text":112,"@type":113},"The manual is intended as a reference guide and is not a substitute for training by experienced and properly trained BuildBlock professionals.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What product warning does the manual give about ACQ-treated wood?",{"text":117,"@type":113},"ACQ (alkaline copper quaternary) treated wood products can be highly corrosive to metal components, so metal parts must be compatible with the treated lumber and corrosion-resistant connectors and fasteners should be specified.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the warranty coverage limits and requirements?",{"text":121,"@type":113},"BuildBlock ICF forms are warranted for 180 days from the invoice shipping date to the original purchaser for defects affecting usability or performance as designed. Coverage depends on handling, storage, transportation, and installation per the manual and related instructions, with written defect notice and proof of purchase provided within the stated time limits.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663421,1793227640,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},1099529839291,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","R E S I D E N T I A L | C O M M E R C I A L | I N D U S T R I A L | I N S T I T U T I O N A L  \nB U I L D I N G S Y S T E M S  \nR E S I D E N T I A L | C O M M E R C I A L | I N D U S T R I A L | I N S T I T U T I O N A L  \nLEARN MORE ONLINE AT BUILDBLOCK. COM/TRAINING  \nBUILDBLOCK BUILDING SYSTEMS  \nICF INSTALLATION & TECHNICAL MANUAL  \nR E S I D E N T I A L | C O M M E R C I A L | I N D U S T R I A L | I N S T I T U T I O N A L  \nBUILDBLOCK TECHNICAL & INSTALLATION BINDER  \nBUILDBLOCK BUILDING SYSTEMS INSTALLATION MANUAL  \nINTRODUCTION  \nThis version of the installation manual was published on June 30, 2015. Changes to this document, however, may occur without notice and users should contact BuildBlock Building Systems LLC, for the most current printed or downloadable version [at](at www.buildblock.com. It)[ ](at www.buildblock.com. It)[www.buildblock.com](at www.buildblock.com. It)[. It](at www.buildblock.com. It) is the purchaser’s and/or contractor’s responsibility to always use the most current and up-to-date version of the installation manual when installing BuildBlock forms and/or products.  \nThis manual was designed to be used as a reference guide only. This manual is not intended to be used as a replacement or substitute for the actual training by an experienced and properly trained BuildBlock building professional. Before starting any project BuildBlock recommends that you receive proper training. BuildBlock also recommends that you consult with design professionals familiar with the type and scope of project to be built. Training is available by contacting BuildBlock Building Systems LLC [at](at www.buildblock.com)[ ](at www.buildblock.com)[www.buildblock.com](at www.buildblock.com) or 866-222-2575.  \nBuildBlock Building Systems, LLC, believes the information contained herein to be accurate at the time of writing and preparation. The information has been compiled using sources believed to be reliable. Neither BuildBlock Building Systems, LLC, nor its employees or representatives make any representation or warranty, either expressed or implied, whether arising by statute, operation of law, custom of trade or otherwise, with respect to the accuracy or completeness of information contained in this document or its fitness for any particular purpose, nor do they assume any liability for damages or injury resulting from the application of such information.  \nBuildBlock Building Systems, LLC, assumes no responsibility regarding the use of its products or any other third party products referred to in this document. It is the full responsibility of the user to comply with all applicable regulations and building code requirements concerning the use of these products and any other products outlined in this product manual. It is further the responsibility of the user to research and understand safe methods of use and handling of these products. To properly comply with the building codes in your area, contact your local distributor, dealer, or building code inspector.  \nPRODUCT WARNINGS  \nMany new types of treated wood products using ACQ (alkaline copper quaternary) are highly corrosive to metal components. BuildBlock Building Systems LLC recommends that any metal products or components should not be used in contact with these treated lumber products unless you ensure the compatibility of your treated lumber with the metal components. Please consult with your project engineer to specify the type and sizing of all corrosion resistant metal connectors, anchor bolts, fasteners  \nor other metal components. Please note that metal connectors, anchor bolts, fasteners or other metal components will corrode and loose their load carrying capacity, if installed in corrosive environments.  \nTRADEMARKS  \nBuildBlock or BB BuildBlock, BuildLock, GlobalBlock, ThermalSert, BuildClip, BuildBrace, BuildDeck, BuildBlock Hardwall, and any other drawings, symbols, or marks identifying products and/or services of BuildBlock Building Systems LLC are r","cbCaifqwzmfQrio7","https://ap.wps.com/l/cbCaifqwzmfQrio7","pdf",8556343,123,"English","# Introduction\n# Product Warnings\n# Trademarks\n# Acknowledgments\n# Limited Product Warranty","[{\"question\":\"What is the purpose of this installation manual?\",\"answer\":\"The manual is intended as a reference guide and is not a substitute for training by experienced and properly trained BuildBlock professionals.\"},{\"question\":\"What product warning does the manual give about ACQ-treated wood?\",\"answer\":\"ACQ (alkaline copper quaternary) treated wood products can be highly corrosive to metal components, so metal parts must be compatible with the treated lumber and corrosion-resistant connectors and fasteners should be specified.\"},{\"question\":\"What are the warranty coverage limits and requirements?\",\"answer\":\"BuildBlock ICF forms are warranted for 180 days from the invoice shipping date to the original purchaser for defects affecting usability or performance as designed. Coverage depends on handling, storage, transportation, and installation per the manual and related instructions, with written defect notice and proof of purchase provided within the stated time limits.\"}]","BUILDBLOCK ICF Installation & Technical Manual | PDF",310]