[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663989-105":59,"doc-detail-663989-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","brisbane-city-council-standard-drawing-kerb-ramp-version-c","Brisbane City Council Standard Drawing - Kerb Ramp - Version C","","This technical document presents the official standard design specifications for kerb ramps, as issued by the Brisbane City Council (BSD-5231). The documentation provides detailed engineering layouts for both Type 'D' and Type 'E' kerb and channel configurations, emphasizing the monolithic casting requirements, required ramp slopes of 1 in 8, and the integration of tactile ground surface indicators (TGSI). It includes a perspective view of the ramp structure, maneuvering areas, and specific directional kerb ramp details to ensure accessibility and safety compliance. The drawing incorporates revisions up to April 2019, specifically detailing updates to TGSI sections and ramp wing grades, and serves as the primary reference for local civil construction projects requiring standard kerb ramp infrastructure.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":57,"@type":76,"position":81},"https://docshare.wps.com/document/general/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/brisbane-city-council-standard-drawing-kerb-ramp-version-c/663989/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/brisbane-city-council-standard-drawing-kerb-ramp-version-c/663989.png","ImageObject",300,407,{"name":92,"@type":93},"Syukur Setiap Hari","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the required slope for a standard kerb ramp?","Question",{"text":112,"@type":113},"The standard kerb ramp slope is specified as 1 in 8.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Are tactile ground surface indicators required for the kerb ramps?",{"text":117,"@type":113},"Yes, tactile ground surface indicators are required where specified in the drawing notes.",{"name":119,"@type":110,"acceptedAnswer":120},"What types of kerb and channel are detailed in this document?",{"text":121,"@type":113},"The document details Type 'D' and Type 'E' kerb and channel sections.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663989,1793235999,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":56,"category_name":57,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":8,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":14},962093541965,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","| \u003Cbr>\u003Cbr>KERB RAMP IS TO BE CAST MONOLITHICALLY. REFER NOTE 4\u003Cbr>WARNING TACTILE GROUND\u003Cbr>SURFACE INDICATORS WHERE~~  ~~REQUIRED. REFER TO NOTES 6, 7 & 8\u003Cbr>\u003Cbr>1520 MAX.\u003Cbr>\u003Cbr>125\u003Cbr>NOM INAL FACE OF KERB\u003Cbr>~~ ~~ INVERT\u003Cbr>\u003Cbr>WARNING TACTILE GROUND SURFACE INDICATORS WHERE REQUIRED. REFER TO NOTES 6, 7 & 8\u003Cbr>\u003Cbr>RAMP SLOPE 1 IN 8\u003Cbr>100\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>TYPE 'D' KERB & CHANNEL\u003Cbr>KERB RAMP IS TO BE CAST MONOLITHICALLY. REFER NOTE 4\u003Cbr>NOM INAL FACE OF KERB\u003Cbr>\u003Cbr>\u003Cbr>INVERT\u003Cbr>\u003Cbr>\u003Cbr>PATH AREA BEHIND KERB RAMP\u003Cbr>  CREASE LINE\u003Cbr>HARDSTAND AND\u003Cbr>\u003Cbr>MANEUVERING AREAS\u003Cbr>RAMP SLOPE 1 IN 8\u003Cbr>\u003Cbr>\u003Cbr>TYPE 'E' KERB & CHANNEL\u003Cbr>SECTION TYPE 'D' KERB & CHANNEL SECTION TYPE 'E' KERB & CHANNEL  PERSPECTIVE VIEW\u003Cbr>HARDSTAND AND MANEUVERING AREA (MAX. GRADE 1 IN 10)\u003Cbr>RAMP WINGS TYP.\u003Cbr>\u003Cbr>GRADE 1 IN 4\u003Cbr>\u003Cbr>NOMINAL FACE OF KERB~~ ~~\u003Cbr>\u003Cbr>CREASE LINE\u003Cbr>\u003Cbr>  NOMINAL FACE\u003Cbr>OF KERB\u003Cbr>SAW CUT THROUGH ~~ ~~KERBAND CHANNEL\u003Cbr>\u003Cbr>\u003Cbr>  CENTRELINE OF PATH AND RAMP\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>600 KERB TAPER\u003Cbr>HARDSTAND AND MANEUVERING AREA\u003Cbr>\u003Cbr>(STANDARD KERB RAMP, TYPE 'E' K&C)\u003Cbr>DIRECTIONAL KERB RAMP\u003Cbr>DIRECTION OF   TRAVEL \u003Cbr>\u003Cbr>\u003Cbr>STANDARD KERB RAMP\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>|  |  |  |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  | | \u003Cbr>| \u003Cbr>BSD-5231 (C) Kerb ramp.dwg |  | BRISBANE CITY COUNCIL STANDARD DRAWING |  |\n|  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  | KERB RAMP |  NOT TO SCALE\u003Cbr>\u003Cbr>BSD-5231   C\u003Cbr>|\n| C | TGSI Detail to Sections & Note 8 Added, . Ramp Width Note Ref. in Details Updated | FEB '19 | APR '19 | Apr\u003Cbr>RPEQ 16110  '19 |  |  |  |  |  |  |\n| B | Ramp Wing Grades Clarified | MAR '18 | JUL '18 | NOV '18 | \u003Cbr>|  |  |  |  |  |\n| A | Drawing Converted from UMS Series April 2014 | APR '14 | APR '14 | APR '14 |  |  |  |  |  |  |\n| | | | | |  | | SUPERSEDES UMS-213 |  |  |  |","cbCainyU5Bj6rcEZ","https://ap.wps.com/l/cbCainyU5Bj6rcEZ","pdf",144722,"English","# Kerb Ramp Design Specifications\n## Structural Details and Types\n## Technical Notes and Installation Requirements\n## Revision History","[{\"question\":\"What is the required slope for a standard kerb ramp?\",\"answer\":\"The standard kerb ramp slope is specified as 1 in 8.\"},{\"question\":\"Are tactile ground surface indicators required for the kerb ramps?\",\"answer\":\"Yes, tactile ground surface indicators are required where specified in the drawing notes.\"},{\"question\":\"What types of kerb and channel are detailed in this document?\",\"answer\":\"The document details Type 'D' and Type 'E' kerb and channel sections.\"}]","Brisbane City Council Standard Drawing - Kerb Ramp - Version C | PDF"]