[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-650718-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-650718-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","breechings-chimneys-and-stacks-section-23-51-00","BREECHINGS, CHIMNEYS, AND STACKS - SECTION 23 51 00","","Specification section for breechings, chimneys, and stacks in a construction project, covering listed double-wall vents, field-fabricated metal breechings and chimneys, and listed grease and dishwasher ducts. Defines applicable related documents, reference standards (NFPA, UL, SMACNA, AWS, ASHRAE), and quality assurance requirements including source limitations and welding qualifications. Includes submittals for product data and shop drawings, delivery/storage/handling, special warranty terms, and requirements for manufacturers and listed vent types.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/breechings-chimneys-and-stacks-section-23-51-00/650718/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/breechings-chimneys-and-stacks-section-23-51-00/650718.png","ImageObject",300,407,{"name":42,"@type":43},"Marglet","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What systems are included in this section?","Question",{"text":63,"@type":64},"It includes listed double-wall vents, field-fabricated metal breechings and chimneys, and listed grease and dishwasher ducts.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which standards govern materials and installation requirements?",{"text":68,"@type":64},"Requirements reference NFPA 211, UL safety standards, SMACNA low pressure duct standards, AWS welding codes, and ASHRAE equipment handbook guidance for chimney, gas vent, and fireplace systems.",{"name":70,"@type":61,"acceptedAnswer":71},"What quality assurance and welding requirements apply?",{"text":72,"@type":64},"Listed components must be obtained from one source/manufacturer, and welding processes and operators must be qualified under AWS D1.1 and AWS D9.1 for the applicable welding scopes. Manufacturer-certified venting system sizing calculations are also required.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},650718,1792879007,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":111,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":117},2336477982702,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","University of Houston Master Construction Specifications Insert Project Name  \nSECTION 23 51 00 – BREECHINGS, CHIMNEYS, AND STACKS  \nPART 1-GENERAL  \n1.01 RELATED DOCUMENTS  \nA. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.  \nB. Specifications throughout all Divisions of the Project Manual are directly applicable to this Section, and this Section is directly applicable to them.  \n1.02 SUMMARY  \nA. This Section includes the following:  \n1. Listed double-wall [vents][chimneys] .  \n2. Field-fabricated metal breechings [and chimneys] .  \n3. Listed [grease][dishwasher][grease and dishwasher] ducts.  \n1.03 REFERENCE STANDARDS  \nA. The latest published edition of a reference shall be applicable to this Project unless identified by a specific edition date.  \nB. All reference amendments adopted prior to the effective date of this Contract shall be applicable to this Project.  \nC. All materials, installation and Workmanship shall comply with the applicable requirements and standards addressed within the following references:  \n1. NFPA: Comply with NFPA 211 \"Standard for Chimneys, Fireplaces, Vents and Solid Fuel Burning Appliances\".  \n2. UL: Comply with applicable portions of UL safety standards; provide products which have been UL listed and labeled.  \n3. SMACNA: Comply with SMACNA Low Pressure Duct Standards for fabricated breeching and smokepipe.  \n4. AWS: Comply with AWS Structural Welding Code for welders' qualifications, welding details, and Workmanship standards.  \n5. ASHRAE: Comply with the ASHRAE Equipment Handbook, Chapter 27, for Chimney, Gas Vent, and Fireplace Systems, material requirements and design criteria.  \n1.04 QUALITY ASSURANCE  \nA. Source Limitations: Obtain listed system components through one source from a single manufacture.  \nAE Project Number: Chimneys, Breeching and Stacks 23 51 00 – 1  \nRevision Date: 1/29/2014  \nUniversity of Houston Master Construction Specifications Insert Project Name  \nB. Welding: Qualify processes and operators according to AWS D1 . 1, \"Structural Welding Code--Steel,\" for hangers and supports and AWS D9 . 1, \"Sheet Metal Welding Code,\" for shop and field welding of joints and seams in vents, breechings, and stacks.  \nC. Certified Sizing Calculations: Manufacturer shall certify venting system sizing calculations.  \n1.05 SUBMITTALS  \nA. Product Data: Furnish product data for the following:  \n1. Type B and BW vents.  \n2. Type L vents.  \n3. Special gas vents.  \n4. Building-heating-appliance chimneys.  \n5. Grease ducts.  \n6. Guy wires and connectors, and installation details.  \nB. Record Documents:  \n1. Shop Drawings for vents, breechings, chimneys, and stacks. Include Drawings, elevations, Sections, details, and attachments to other Work.  \n2. Details equipment assemblies which indicate dimensions, weights, loads, required clearances, methods of field assembly, components, hangers and restraints, includingthe location and the size of each field connection.  \n3. For installed products indicated to comply with design loads, include calculations and structural analysis data signed and sealed by the qualified professional engineer responsible for their preparation.  \n4. Welding certificates.  \n1.06 DELIVERY, STORAGE AND HANDLING  \nA. The Work of this Section shall be coordinated with other trades affecting, or affected by this Work, to assure the steady progress of all Work performed under the Contract.  \nB. Replace any Sections or assemblies damaged during shipment, storage or handling with new identical factory-supplied components.  \nC. Protect finishes from physical damage by leaving factory packing cases in place before installation and providing temporary protective covers after installation with on going construction within the Project Site.  \n1.07 WARRANTY  \nA. Special Warranty: Manufacturer's standard form in which manufacturer agrees to repair or replace components of vent","cbCaivYDQhLTPzrB","https://ap.wps.com/l/cbCaivYDQhLTPzrB","pdf",65451,"English","# PART 1 - GENERAL\n## Related Documents\n## Summary\n## Reference Standards\n## Quality Assurance\n## Submittals\n## Delivery, Storage and Handling\n## Warranty\n# PART 2 - PRODUCTS\n## General\n## Manufacturers\n## Listed Type B and BW Vents","[{\"question\":\"What systems are included in this section?\",\"answer\":\"It includes listed double-wall vents, field-fabricated metal breechings and chimneys, and listed grease and dishwasher ducts.\"},{\"question\":\"Which standards govern materials and installation requirements?\",\"answer\":\"Requirements reference NFPA 211, UL safety standards, SMACNA low pressure duct standards, AWS welding codes, and ASHRAE equipment handbook guidance for chimney, gas vent, and fireplace systems.\"},{\"question\":\"What quality assurance and welding requirements apply?\",\"answer\":\"Listed components must be obtained from one source/manufacturer, and welding processes and operators must be qualified under AWS D1.1 and AWS D9.1 for the applicable welding scopes. Manufacturer-certified venting system sizing calculations are also required.\"}]","BREECHINGS, CHIMNEYS, AND STACKS - SECTION 23 51 00 | PDF",1792840809]