[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-367672-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-367672-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","breast-lesion-classification-via-colorized-mammograms-and-transfer-learning-in-a-novel-cad-framework","Breast lesion classification via colorized mammograms and transfer learning in a novel CAD framework","","Breast lesion classification for mammography is motivated by persistent diagnostic errors in grayscale images, which may obscure contrast between benign and malignant lesions. A novel CAD workflow converts standard grayscale mammograms into RGB via a three-path preprocessing scheme for noise reduction, lesion highlighting, and tumor-centric intensity adjustment using a data-driven transfer function. Machine learning then classifies tumors as malign or benign from the colored images, using pre-training and multiple ML methods. EfficientNetB0 pre-training combined with SVM achieves the best performance, with accuracy up to 99.4% and AUC reaching 100%.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/breast-lesion-classification-via-colorized-mammograms-and-transfer-learning-in-a-novel-cad-framework/367672/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/breast-lesion-classification-via-colorized-mammograms-and-transfer-learning-in-a-novel-cad-framework/367672.png","ImageObject",300,407,{"name":42,"@type":43},"Adam","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-03","2026-09-23",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"How does the proposed CAD system improve mammography contrast for lesion classification?","Question",{"text":63,"@type":64},"It transforms grayscale mammograms into RGB using a three-path preprocessing framework, including noise reduction, lesion highlighting, and tumor-centric intensity adjustment driven by a data-driven transfer function.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which machine learning approach achieved the best classification performance?",{"text":68,"@type":64},"EfficientNetB0 pre-training combined with Support Vector Machines (SVM) produced the optimal results across accuracy, sensitivity, specificity, precision, F1-score, and AUC.",{"name":70,"@type":61,"acceptedAnswer":71},"What metrics are used to evaluate the CAD framework?",{"text":72,"@type":64},"The study evaluates accuracy, sensitivity, specificity, precision, F1-score, and Area Under the Curve (AUC) to measure the effectiveness of the preprocessing and ML methods.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},367672,1790278824,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},1374404737137,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nBreast lesion classification via colorized mammograms and transfer learning in a novel CAD framework  \nAbbas Ali Hussein􀀍, MortezaValizadeh􀀍, Mehdi Chehel Amirani & Sedighe Mirbolouk  \nMedical imaging sciences and diagnostic techniques for Breast Cancer (BC) imaging have advanced tremendously, particularly with the use of mammography images; however, radiologists may still misinterpret medical images of the breast, resulting in limitations and flaws in the screening process. As a result, Computer-Aided Design (CAD) systems have become increasingly popular due to their ability to operate independently of human analysis. Current CAD systems use grayscale analysis, which lacks the contrast needed to differentiate benign from malignant lesions. As part of this study, an innovative CAD system is presented that transforms standard grayscale mammography images into RGB colored through a three-path preprocessing framework developed for noise reduction, lesion highlighting, and tumor-centric intensity adjustment using a data-driven transfer function. In contrast to a generic approach, this approach statistically tailors colorization in order to emphasize malignant regions, thus enhancing the ability of both machines and humans to recognize cancerous areas. As a consequence of this conversion, breast tumors with anomalies become more visible, which allows us to extract more accurate features about them. In a subsequent step, Machine Learning (ML) algorithms are employed to classify these tumors as malign or benign cases. A pre-trained model is developed to extract comprehensive features from colored mammography images by employing this approach. A variety of techniques are implemented in the pre-processing section to minimize noise and improve image perception; however, the most challenging methodology is the application of creative techniques to adjust pixels’ intensity values in mammography images using a data-driven transfer function derived from tumor intensity histograms. This adjustment serves to draw attention to tumors while reducing the brightness of other areas in the breast image. Measuring criteria such as accuracy, sensitivity, specificity, precision, F1-Score, and Area Under the Curve (AUC) are used to evaluate the efficacy of the employed methodologies. This work employed and tested a variety of pre-training and ML techniques. However, the combination of EfficientNetB0 pre-training with ML Support Vector Machines (SVM) produced optimal results with accuracy, sensitivity, specificity, precision, F1-Score, andAUC, of 99.4%, 98.7%, 99.1%, 99%, 98.8%, and 100%, respectively. It is clear from these results that the developed method does not only advance the state-of-the-art in technical terms, but also provides radiologists with a practical tool to aid in the reduction of diagnostic errors and increase the detection of early breast cancer.  \nKeywords Breast cancer (BC) prediction, Computer-aided design (CAD), Pre-training, Mammogram colorization, Transfer learning (TL), Machine learning (ML)  \nCells continuously regenerate throughout the body while the body’s natural operating mechanism is maintained by a balanced rate of cell growth and death. Occasionally, this may not be the case and a small number of cells may begin to develop irregularly. Generally, cancer is caused by the growth of abnormally proliferating cells. These cells grow out of control, form tumors, and are fatal if they are left untreated. The World Health Organization (WHO) reported in 2022 that over two million cases of Breast Cancer (BC) had been diagnosed, resulting in over 670,000 deaths1,2. While risk reduction strategies may be utilized to mitigate a substantial portion of these losses, numerous women do not participate in Breast Self-exams (BSEs) or receive adequate  \nDepartment of Electrical Engineering, Faculty of Electrical and Computer Engineering, Urmia University, Urmi","cbCaiu1dI86k7btP","https://ap.wps.com/l/cbCaiu1dI86k7btP","pdf",3526654,22,"English","# Introduction\n## Breast cancer burden and screening challenges\n## Mammography and CAD background\n# Proposed method\n## Colorization via three-path preprocessing and data-driven transfer function\n## Tumor-centric intensity adjustment and feature extraction\n## ML classification and evaluation metrics\n# Results\n## Optimal EfficientNetB0 + SVM performance","[{\"question\":\"How does the proposed CAD system improve mammography contrast for lesion classification?\",\"answer\":\"It transforms grayscale mammograms into RGB using a three-path preprocessing framework, including noise reduction, lesion highlighting, and tumor-centric intensity adjustment driven by a data-driven transfer function.\"},{\"question\":\"Which machine learning approach achieved the best classification performance?\",\"answer\":\"EfficientNetB0 pre-training combined with Support Vector Machines (SVM) produced the optimal results across accuracy, sensitivity, specificity, precision, F1-score, and AUC.\"},{\"question\":\"What metrics are used to evaluate the CAD framework?\",\"answer\":\"The study evaluates accuracy, sensitivity, specificity, precision, F1-score, and Area Under the Curve (AUC) to measure the effectiveness of the preprocessing and ML methods.\"}]","Breast lesion classification via colorized mammograms and transfer learning in a novel CAD framework | PDF",1790171908,55,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/bf3cc145e27725e968a26dcb458584d6.webp",983,1291,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/5cc7d00572373dd1a1b51926e2c8f804.webp",982,1290,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/39906791e4a1a1249abcec7a79b59b19.webp",981,1289,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/93bbc131f7a8bf8e1e7a0502abb7441d.webp",980,1287]