[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-detail-181512-en":59,"doc-seo-181512-105":79},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":5,"data":60},{"doc_id":61,"user_id":62,"nickname":63,"user_avatar":64,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":66,"doc_content":67,"file_id":68,"file_url":69,"file_type":70,"file_size":71,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":72,"language_code":73,"site_id":74,"html_lang":73,"table_of_contents":75,"faqs":76,"seo_title":77,"seo_description":66,"update_tm":78,"read_time":46},181512,962075114765,"Quinn","https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Breaker Zone Interlock Connector - Caution and Pickup Limits Tables","Caution information and operating pickup limit tables for a breaker zone interlock connector are provided, including installed rating and amperes pickup/dial amperage settings. The tables list long delay pickup limits and short delay plus instantaneous pickup limits, expressed as multiples of ampere values with corresponding amperage ranges. Additional guidance covers ground pickup values across dial sensor rating settings, mapping to secondary current levels for multiple pickup sensitivity bands.","| | CAUTION |\n| --- | --- |\n\n\n| Installed\u003Cbr>Rating\u003Cbr>Plug\u003Cbr>Amperes\u003Cbr>(ln) | Pickup (Dial) Setting\u003Cbr>Amperes 1 |  |  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  | A 2 | B 2 | C 2 | D 2 | E 2 | F | H | K |\n| 100\u003Cbr>200\u003Cbr>250\u003Cbr>300\u003Cbr>400\u003Cbr>600\u003Cbr>800\u003Cbr>1000\u003Cbr>1200\u003Cbr>1600\u003Cbr>2000\u003Cbr>2400\u003Cbr>3200\u003Cbr>4000 | 25\u003Cbr>50\u003Cbr>63\u003Cbr>75\u003Cbr>100\u003Cbr>150\u003Cbr>200\u003Cbr>250\u003Cbr>300\u003Cbr>400\u003Cbr>500\u003Cbr>600\u003Cbr>800\u003Cbr>1000 | 30\u003Cbr>60\u003Cbr>75\u003Cbr>90\u003Cbr>120\u003Cbr>180\u003Cbr>240\u003Cbr>300\u003Cbr>360\u003Cbr>480\u003Cbr>600\u003Cbr>720\u003Cbr>960 | 35\u003Cbr>70\u003Cbr>88\u003Cbr>105\u003Cbr>140\u003Cbr>210\u003Cbr>280\u003Cbr>350\u003Cbr>420\u003Cbr>560\u003Cbr>700\u003Cbr>840\u003Cbr>1120 | 40\u003Cbr>80\u003Cbr>100\u003Cbr>120\u003Cbr>160\u003Cbr>240\u003Cbr>320\u003Cbr>400\u003Cbr>480\u003Cbr>640\u003Cbr>800\u003Cbr>960 | 50\u003Cbr>100\u003Cbr>125\u003Cbr>150\u003Cbr>200\u003Cbr>300\u003Cbr>400\u003Cbr>500\u003Cbr>600\u003Cbr>800\u003Cbr>1000 | 60\u003Cbr>120\u003Cbr>150\u003Cbr>180\u003Cbr>240\u003Cbr>360\u003Cbr>480\u003Cbr>600\u003Cbr>720\u003Cbr>960 | 75\u003Cbr>150\u003Cbr>188\u003Cbr>225\u003Cbr>300\u003Cbr>450\u003Cbr>600\u003Cbr>750\u003Cbr>900 | 100\u003Cbr>200\u003Cbr>250\u003Cbr>300\u003Cbr>400\u003Cbr>600\u003Cbr>800\u003Cbr>1000 |\n|  |  |  |  |  |  |  |  | 1200\u003Cbr>1200\u003Cbr>1200\u003Cbr>1200\u003Cbr>1200\u003Cbr>1200 |\n|  |  |  |  |  |  |  | 1200\u003Cbr>1200\u003Cbr>1200\u003Cbr>1200\u003Cbr>1200 |  |\n|  |  |  |  |  |  | 1200\u003Cbr>1200\u003Cbr>1200\u003Cbr>1200 |  |  |\n|  |  |  |  |  | 1200\u003Cbr>1200\u003Cbr>1200 |  |  |  |\n|  |  |  |  | 1200\u003Cbr>1200 |  |  |  |  |\n|  |  | 1200 | 1200 |  |  |  |  |  |\n\n\n| | CAUTION |\n| --- | --- |\n\n| | | | |\n| --- | --- | --- | --- |\n| FRONT VIEW OF BREAKER ZONE INTERLOCK CONNECTOR\u003Cbr>Located upper right rear (from front) |  |  |  |\n\n\n| Long\u003Cbr>Delay | Pickup\u003Cbr>Limits\u003Cbr>(Amps) |  | Short Delay\u003Cbr>and\u003Cbr>Instantaneous | Pickup\u003Cbr>Limits\u003Cbr>(Amps) |\n| --- | --- | --- | --- | --- |\n| .5X = 2.5 Amp | 2.25 to 2.75 |  | 4X = 20 Amp | 18 to 22 |\n| .6X = 3.0 | 2.7 to 3.3 |  | 5X = 25 | 22.5 to 27.5 |\n| .7X = 3.5 | 3.15 to 3.85 |  | 6X = 30 | 27 to 33 |\n| .8X = 4.0 | 3.6 to 4.4 |  | 7X = 35 | 31.5 to 38.5 |\n| .9X = 4.5 | 4.05 to 4.95 |  | 8X = 40 | 36 to 44 |\n| 1.0X = 5.0 | 4.5 to 5.5 |  | 10X = 50 | 45 to 55 |\n| 1.25X = 6.25 | 5.6 to 6.9 |  |  |  |\n\n\n| Ground Pickup Value – Amperes |  |\n| --- | --- |\n| Dial Sensor Rating\u003Cbr>Setting 50 100 150 200 300 400 600 800 1200 1600 2000 2400 3200 4000 | Secondary\u003Cbr>Current 1 |\n| A 13 57 60 65 80 110 145 180 260 330 400 530 640 800 | 1.0 |\n| B 18 67 75 85 110 150 205 260 385 505 600 770 1000 1200 | 1.5 |\n| C 22 75 85 100 130 185 250 325 480 625 760 960 1200 N.A. | 1.9 |\n| D 33 100 120 145 200 270 385 500 730 970 1200 N.A. N.A. N.A. | 3.0 |","cbCaicDAn0yhu187","https://ap.wps.com/l/cbCaicDAn0yhu187","pdf",101340,"English","en",105,"# Caution\n## Installed Rating and Pickup (Dial) Settings\n## Long Delay Pickup Limits and Short Delay/Instantaneous Pickup Limits\n## Ground Pickup Value Tables","[{\"question\":\"What does the document caution section apply to?\",\"answer\":\"It applies to the breaker zone interlock connector operation and its pickup-limit settings.\"},{\"question\":\"How are long delay pickup limits specified?\",\"answer\":\"They are given as multiples of ampere values (e.g., 0.5X, 0.6X, etc.) with corresponding pickup amperage ranges.\"},{\"question\":\"Where are ground pickup values defined?\",\"answer\":\"Ground pickup values are provided in tables that link dial sensor rating settings to secondary current levels.\"}]","Breaker Zone Interlock Connector - Caution and Pickup Limits Tables | PDF",1788344975,{"code":4,"msg":80,"data":81},"ok",{"site_id":74,"language":73,"slug":82,"title":65,"keywords":83,"description":66,"schema_data":84,"social_meta":138,"head_meta":140,"extra_data":142,"updated_unix":143},"breaker-zone-interlock-connector-caution-and-pickup-limits-tables","",{"@graph":85,"@context":137},[86,100,120],{"@type":87,"itemListElement":88},"BreadcrumbList",[89,93,95,98],{"item":90,"name":91,"@type":92,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":94,"name":9,"@type":92,"position":14},"https://docshare.wps.com/document/",{"item":96,"name":30,"@type":92,"position":97},"https://docshare.wps.com/document/technology/",3,{"item":99,"name":65,"@type":92,"position":19},"https://docshare.wps.com/document/breaker-zone-interlock-connector-caution-and-pickup-limits-tables/181512/",{"url":99,"name":65,"@type":101,"image":102,"author":107,"headline":65,"publisher":109,"fileFormat":112,"inLanguage":73,"description":66,"dateModified":113,"datePublished":114,"encodingFormat":112,"isAccessibleForFree":115,"interactionStatistic":116},"DigitalDocument",{"url":103,"@type":104,"width":105,"height":106},"https://docshare.wps.com/thumbnails/breaker-zone-interlock-connector-caution-and-pickup-limits-tables/181512.png","ImageObject",300,407,{"name":63,"@type":108},"Person",{"url":90,"name":110,"@type":111},"DocShare","Organization","application/pdf","2026-10-07","2026-09-02",true,{"@type":117,"interactionType":118,"userInteractionCount":19},"InteractionCounter",{"@type":119},"ViewAction",{"@type":121,"mainEntity":122},"FAQPage",[123,129,133],{"name":124,"@type":125,"acceptedAnswer":126},"What does the document caution section apply to?","Question",{"text":127,"@type":128},"It applies to the breaker zone interlock connector operation and its pickup-limit settings.","Answer",{"name":130,"@type":125,"acceptedAnswer":131},"How are long delay pickup limits specified?",{"text":132,"@type":128},"They are given as multiples of ampere values (e.g., 0.5X, 0.6X, etc.) with corresponding pickup amperage ranges.",{"name":134,"@type":125,"acceptedAnswer":135},"Where are ground pickup values defined?",{"text":136,"@type":128},"Ground pickup values are provided in tables that link dial sensor rating settings to secondary current levels.","https://schema.org",{"og:url":99,"og:type":139,"og:title":65,"og:site_name":110,"og:description":66},"article",{"robots":141,"canonical":99},"index,follow",{"doc_id":61,"site_id":74},1791111005]