[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-203134-105":59,"doc-detail-203134-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","branching-modules-frmdistributor-blocks-frz-d-series-metal-design","Branching modules FRM/distributor blocks FRZ - D series - metal design","","Overview of Festo branching modules and FRM distributor blocks with FRZ variants in the D series, including metal design options. Tables compare product range configurations and service unit component combinations, covering pneumatic connection sizes, pressure regulation ranges, and filtration grade requirements. Additional sections map available functional features such as bowl guards, condensate drain types, pressure indication, actuator lock options, and supply voltages (24 V DC, 110 VAC, 230 VAC).",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/branching-modules-frmdistributor-blocks-frz-d-series-metal-design/203134/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/branching-modules-frmdistributor-blocks-frz-d-series-metal-design/203134.png","ImageObject",300,407,{"name":92,"@type":93},"Olivia Brown","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-08","2026-09-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What product series are covered in this datasheet?","Question",{"text":113,"@type":114},"It covers branching modules FRM/distributor blocks FRZ in the D series, including a metal design variant.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Which technical parameters are compared in the tables?",{"text":118,"@type":114},"The document compares pneumatic connection sizes, pressure regulation ranges, and filtration grade requirements, along with where specific features are available.",{"name":120,"@type":111,"acceptedAnswer":121},"What option types are listed for service unit configurations?",{"text":122,"@type":114},"Options include bowl guard materials, condensate drain modes, pressure indication methods, actuator lock types, and supply voltages (24 V DC, 110 VAC, 230 VAC).","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},203134,1788555947,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":130,"read_time":145},16904993612988,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Branching modules FRM/distributor blocks FRZ, D series  \nBranching modules FRM/distributor blocks FRZ, D series, metal design  \nProduct range overview – Service unit components, D series, metal  \n\n| Type |  | Size |  | Pneumatic connection |  |  |  |  |  |  |  |  |  | Pressure regulation range\u003Cbr>[bar] |  |  | Grade of filtration\u003Cbr>[μm] |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  | M5 | M7 | G1/8 | G1/4 | G3/8 | G1/2 | G3/4 | G1 | QS4 | QS6 | 0.5\u003Cbr>...\u003Cbr>7 | 0.5\u003Cbr>...\u003Cbr>12 | 2.5\u003Cbr>...\u003Cbr>12 | 0.01 | 1 | 5 | 40 |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Service units |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| FRC/FRCS |  |  | Mini | – | – | h | h | h | – | – | – | – | – | h | h | – | – | – | h | h |\n|  |  |  | Midi | – | – | – | h | h | h | h | – | – | – | h | h | – | – | – | h | h |\n|  |  |  | Maxi | – | – | – | – | – | h | h | h | – | – | h | h | – | – | – | h | h |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Service unit combinations |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| FRC-K |  |  | Micro | – |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  | Mini | – | – | h | h | – | – | – | – | – | – | – | h | h | – | – | – | h |\n|  |  |  | Midi | – | – | – | h | h | h | – | – | – | – | – | h | h | – | – | – | h |\n|  |  |  | Maxi | – | – | – | – | – | h | h | – | – | – | – | h | h | – | – | – | h |\n| LFR-K\u003Cbr>LFRS-K | |  | Micro | – |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  | Mini | – | – | h | h | – | – | – | – | – | – | – | h | h | – | – | – | h |\n|  |  |  | Midi | – | – | – | h | h | h | – | – | – | – | – | h | h | – | – | – | h |\n|  |  |  | Maxi | – | – | – | – | – | h | h | – | – | – | – | h | h | – | – | – | h |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Individual devices |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Filter regulators\u003Cbr>LFR/LFRS | |  | Micro | h | h | h | – | – | – | – | – | h | h | h | – | – | – | – | h | – |\n|  |  |  | Mini | – | – | h | h | h | – | – | – | – | – | h | h | – | – | – | h | h |\n|  |  |  | Midi | – | – | – | h | h | h | h | – | – | – | h | h | – | – | – | h | h |\n|  |  |  | Maxi | – | – | – | – | – | h | h | h | – | – | h | h | – | – | – | h | h |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Filters\u003Cbr>LF | |  | Mini | – | – | h | h | h | – | – | – | – | – | – | – | – | – | – | h | h |\n|  |  |  | Midi | – | – | – | h | h | h | h | – | – | – | – | – | – | – | – | h | h |\n|  |  |  | Maxi | – | – | – | – | – | h | h | h | – | – | – | – | – | – | – | h | h |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n| Fine and micro filters\u003Cbr>LFMA/LFMB | |  | Micro | – |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  | Mini | – | – | h | h | h | – | – | – | – | – | – | – | – | h | h | – | – |\n|  |  |  | Midi | – | – | – | h | h | h | h | – | – | – | – | – | – | h | h | – | – |\n|  |  |  | Maxi | – | – | – | – | – | h | h | h | – | – | – | – | – | h | h | – | – |\n| Activated carbon filters\u003Cbr>LFX | |  | Micro | – |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  | Mini | – | – | h | h | h | – | – | – | – | – | – | – | – | – | – | – | – |\n|  |  |  | Midi | – | – | – | h | h | h | h | – | – | – | – | – | – | – | – | – | – |\n|  |  |  | Maxi | – | – | – | – | – | h | h | h | – | – | – | – | – | – | – | – | – |\n| Filter\u003Cbr>combinations\u003Cbr>LFMBA | |  | Micro | – |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |\n|  |  |  | Mini | – | – | h | h | h | – | – | – | – | – | – | – | – | h | h | – | – |\n|  |  |  | Midi | – | – | – | h | h | h | h | – | – | – | – | – | – | h | h | – | – |\n|  |  |  | Maxi | – | – | – | – | – | h | h | h | – | – | – | – | – | h | h | – | – |\n|  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |  |","cbCaieRtCdlDXM7C","https://ap.wps.com/l/cbCaieRtCdlDXM7C","pdf",812596,15,"English","# Branching modules and distributor blocks\n## Product range overview\n## Service unit components comparison\n## Service unit combinations\n## Individual devices and filter systems\n## Pressure regulators and related options","[{\"question\":\"What product series are covered in this datasheet?\",\"answer\":\"It covers branching modules FRM/distributor blocks FRZ in the D series, including a metal design variant.\"},{\"question\":\"Which technical parameters are compared in the tables?\",\"answer\":\"The document compares pneumatic connection sizes, pressure regulation ranges, and filtration grade requirements, along with where specific features are available.\"},{\"question\":\"What option types are listed for service unit configurations?\",\"answer\":\"Options include bowl guard materials, condensate drain modes, pressure indication methods, actuator lock types, and supply voltages (24 V DC, 110 VAC, 230 VAC).\"}]","Branching modules FRM/distributor blocks FRZ - D series - metal design | PDF",38]