[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-645797-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-645797-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","bosch-ids-20-split-system-heat-pump-condensing-units-service-manual","Bosch IDS 2.0 Split System Heat Pump Condensing Units - Service Manual","","Bosch IDS 2.0 service manual for split system heat pump condensing units provides technical guidance for installation, field settings, control logic, performance data, and systematic diagnosis. The manual defines safety symbols and warning practices, lists nomenclature and models/part numbers, includes dimensions and AHRI performance information, and covers extended cooling/heating operation data. It further explains layout of functional components, refrigerant flow diagrams, control functions, dip switch settings, fault codes/limited conditions, troubleshooting steps, and advanced system checks using key sensors and actuators.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/bosch-ids-20-split-system-heat-pump-condensing-units-service-manual/645797/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/bosch-ids-20-split-system-heat-pump-condensing-units-service-manual/645797.png","ImageObject",300,407,{"name":42,"@type":43},"xXChrisXx","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-23",true,{"@type":51,"interactionType":52,"userInteractionCount":4},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What safety instructions and symbols are covered in the manual?","Question",{"text":61,"@type":62},"The manual explains how warnings are identified using a warning triangle, and defines DANGER, WARNING, CAUTION, and NOTICE. It also includes key electrical hazard guidance, including disconnect and voltage verification requirements.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"Which topics are included for installation and initial operation setup?",{"text":66,"@type":62},"Field settings cover initial unit preparation and installation checklist, initial start-up checklist, dip switch settings for both outdoor and indoor units, and check point values.",{"name":68,"@type":59,"acceptedAnswer":69},"How does the manual support diagnosis and troubleshooting?",{"text":70,"@type":62},"It provides control board component layouts, fault code and limited condition descriptions, structured troubleshooting for multiple fault codes (e.g., C3, E4, E5, E6, etc.), situational troubleshooting (such as system not starting and poor capacity), and advanced system checks like abnormal pressure and sensor/actuator evaluations.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},645797,1792735489,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,103,108,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":101,"slug":102},6,50,"technology",{"id":104,"doc_module":4,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},7,"Healthcare",40,"healthcare",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},8,"Research & Report",30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":100,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":138,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":78,"read_time":143},8796112263567,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","2.0 IDS  \nService Manual  \nBVA20  \nIDS Premium  \n20 SEER System  \nBOVA20  \nTech Support 866-642-3198  \n[BoschHeatingAndCooling.com](BoschHeatingAndCooling.com)  \nBosch IDS 2.0 Split System Heat Pump Condensing Units Up to 20.5 SEER  \n2-3-4-5 Ton Capacity R410A  \nService Manual  \nService Manual Bosch IDS 2.0 | 3  \nTable of Contents  \n\n| 1 Key to Symbols and Safety Instructions | 4 |\n| --- | --- |\n| 1.1 Key to Symbols | 4 |\n| 1.2 Safety | 4 |\n| 2 Nomenclature | 6 |\n| 2.1 Bosch IDS BVA2.0\u003Cbr>2.2 Bosch IDS BOVA2.0 | 6\u003Cbr>7 |\n| 3 Models & Part Numbers | 8 |\n| 4 Dimensions | 9 |\n| 4.1 Bosch IDS BVA2.0 | 9 |\n| 4.2 Bosch IDS BOVA2.0 | 10 |\n| 5 AHRI 210/240 Performance Data | 11 |\n| 5.1 Bosch IDS BOVA2.0 | 11 |\n| 6 ProductSpeciﬁcations | 12 |\n| 6.1 Bosch IDS BVA2.0 | 12 |\n| 6.2 Bosch IDS BOVA2.0 | 13 |\n| 7 Extended Performance Data | 14 |\n| 7.1 Outdoor Unit (BOVA) + Indoor Unit (BVA)–Cooling Mode | 14 |\n| 7.2 Outdoor Unit (BOVA) + Indoor Unit (BVA)– Heating Mode | 22 |\n| 8 Layout of Functional Components | 26 |\n| 8.1 3 Ton | 26 |\n| 8.2 5 Ton | 27 |\n| 9 Refrigerant Flow Diagrams | 28 |\n| 9.1 Cooling Operation | 28 |\n| 9.2 Heating Operation | 29 |\n| 10 Control | 31 |\n| 10.1 Crankcase Heater Control | 31 |\n| 10.2 Other Operations | 31 |\n| 10.2.1 Defrost Operation | 31 |\n| 10.2.2 Oil Return Operation | 31 |\n| 10.2.2 Force Mode Operation | 32 |\n| 10.2.3 Indoor Fan Motor Function | 32 |\n\n11 Field Settings 33  \n11.1 Initial Unit Preparation and Installation Checklist 33  \n11.2 Initial Start-up Checklist 33  \n11.3 Dip Switch Settings 33  \n11.3.1 Outdoor Unit Dip Switch Settings 33  \n11.3.2 When to Change Outdoor Unit Dip Switch Settings 34  \n11.3.3 Indoor Unit Dip Switch Settings 35  \n11.3.4 When to Change Indoor Unit Dipswitch Settings 35  \n11.4 Check Point Values 36  \n\n| 12 Diagnosis and Troubleshooting | 37 |\n| --- | --- |\n| 12.1 Control Board Component Layout | 37 |\n| 12.1.1 BOVA36 Outdoor Unit Control Board | 37 |\n| 12.1.2 BOVA60 Outdoor Unit Control Board | 38 |\n| 12.1.3 BVA2.0 Indoor Unit Control Board | 39 |\n| 12.2 Fault Code and Limited Condition Descriptions | 40 |\n| 12.3 Fault Codes and Limited Conditions Troubleshooting | 42 |\n| 12.3.1 C3 Troubleshooting | 42 |\n| 12.3.2 E4 Troubleshooting | 43 |\n| 12.3.3 E5 Troubleshooting | 44 |\n| 12.3.4 E6 Troubleshooting | 45 |\n| 12.3.5 E7 Troubleshooting | 46 |\n| 12.3.6 E9 Troubleshooting | 47 |\n| 12.3.7 H0 Troubleshooting | 48 |\n| 12.3.8 H8 Troubleshooting | 49 |\n| 12.3.9 P0 Troubleshooting | 50 |\n| 12.3.10 P1/F1 Troubleshooting | 51 |\n| 12.3.11 P2/H5 Troubleshooting | 52 |\n| 12.3.12 P3 Troubleshooting | 53 |\n| 12.3.13 P4 Troubleshooting | 54 |\n| 12.3.14 P5 Troubleshooting | 55 |\n| 12.3.15 P8 Troubleshooting | 56 |\n| 12.3.16 PH Troubleshooting | 57 |\n| 12.3.17 LO-L9 Troubleshooting | 58 |\n| 12.3.18 AtL Troubleshooting | 59 |\n| 12.4 Situational Troubleshooting | 60 |\n| 12.4.1 LED Display is Blank | 60 |\n| 12.4.2 System Does Not Start | 61 |\n| 12.4.3 Poor Capacity | 62 |\n| 12.4.4 Poor Dehumidiﬁcation | 63 |\n| 13 Advanced System Check | 64 |\n| 13.1 Abnormal Pressure | 64 |\n| 13.2 Pressure Transducer (PT) | 65 |\n| 13.3 Electronic Expansion Valve (EEV) | 66 |\n| 13.4 Temperature Sensor (T3,T4,T5,Th,T3L,Tf) | 67 |\n| 13.5 High Pressure Switch (HPS) | 68 |\n| 13.6 Outdoor Fan Motor | 69 |\n| 13.7 Indoor Blower Motor | 70 |\n| 13.8 Compressor | 71 |\n| 13.9 System Charge | 72 |\n| 13.10 Outdoor Board Fuse | 73 |\n| 13.11 Indoor Board Fuse | 74 |\n\nAppendix 75  \nAppendix 1 Outdoor Unit Control Board 75  \nAppendix 2 Indoor Unit Control Board 77  \nBosch Thermotechnology Corp. | 07.2021 Data subject to change  \n4 | Bosch IDS 2.0 Service Manual  \n1 Key to Symbols and Safety Instructions 1.1 Key to Symbols  \nWarnings  \n\n| | Warnings in this document are identiﬁed by a\u003Cbr>warning triangle printed against a grey background.\u003Cbr>Keywords at the start of a warning indicate the type and seriousness of the ensuing risk if measures to prevent the risk are not taken. |\n| --- | --- |\n\nThe following keywords are deﬁned and can","cbCaiuEtp2tIRVIK","https://ap.wps.com/l/cbCaiuEtp2tIRVIK","pdf",11021821,104,"English","# Table of Contents\n## Key to Symbols and Safety Instructions\n## Nomenclature\n## Models & Part Numbers\n## Dimensions\n## AHRI 210/240 Performance Data\n## Product Specifications\n## Extended Performance Data\n## Layout of Functional Components\n## Refrigerant Flow Diagrams\n## Control\n## Field Settings\n## Diagnosis and Troubleshooting\n## Advanced System Check\n## Appendix","[{\"question\":\"What safety instructions and symbols are covered in the manual?\",\"answer\":\"The manual explains how warnings are identified using a warning triangle, and defines DANGER, WARNING, CAUTION, and NOTICE. It also includes key electrical hazard guidance, including disconnect and voltage verification requirements.\"},{\"question\":\"Which topics are included for installation and initial operation setup?\",\"answer\":\"Field settings cover initial unit preparation and installation checklist, initial start-up checklist, dip switch settings for both outdoor and indoor units, and check point values.\"},{\"question\":\"How does the manual support diagnosis and troubleshooting?\",\"answer\":\"It provides control board component layouts, fault code and limited condition descriptions, structured troubleshooting for multiple fault codes (e.g., C3, E4, E5, E6, etc.), situational troubleshooting (such as system not starting and poor capacity), and advanced system checks like abnormal pressure and sensor/actuator evaluations.\"}]","Bosch IDS 2.0 Split System Heat Pump Condensing Units - Service Manual | PDF",262]