[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-291355-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-291355-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","blower-coil-air-handler-models-bche-and-bcve-product-catalog","Blower Coil Air Handler Models BCHE and BCVE - Product Catalog","","Product catalog for Trane blower coil air handler models BCHE and BCVE, covering single-zone installations with airflow ratings from 400 to 4000 CFM. Describes factory-packaged design, EC motor options, double wall casing, enhanced static coil mounting, and multiple drain pan and filtration configurations including MERV 13. Includes sections on controls and Trane controller options, energy efficiency, indoor air quality, ventilation, dehumidification, acoustics, operating limitations, performance and data.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/blower-coil-air-handler-models-bche-and-bcve-product-catalog/291355/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/blower-coil-air-handler-models-bche-and-bcve-product-catalog/291355.png","ImageObject",300,407,{"name":42,"@type":43},"Emma Mercer","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-10","2026-09-17",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",13,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"Which models are covered in this blower coil product catalog?","Question",{"text":63,"@type":64},"The catalog covers Trane blower coil air handler models BCHE and BCVE.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What airflow range is specified for the single-zone air handler applications?",{"text":68,"@type":64},"The document specifies single-zone air handler applications with airflow from 400 to 4000 CFM.",{"name":70,"@type":61,"acceptedAnswer":71},"What filtration and indoor air quality options are highlighted?",{"text":72,"@type":64},"The catalog highlights filtration options including an MERV 13 filter option and covers indoor air quality topics such as filtration, ventilation, and dehumidification.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},291355,1789644999,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":140,"language":141,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":12,"update_tm":80,"read_time":145,"preview_page_count":4},962084925502,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Product Catalog  \nBlower Coil Air Handler Models BCHE and BCVE  \nSingle Zone Air Handler, 400 to 4000 CFM  \nApril  \n2022  \nBCX-PRC002A-EN  \nIntroduction  \nTrane Blower Coils—Factory Packaged How You Need It... When You Need It  \nFigure 1. Horizontal blower coil (BCHE model)  \nEC Motor  \nDouble wall casing option  \nIncreased static Coil mounting  \npressure capability  \nNon-corrosive drain pan  \nMERV 13 filter option (LEED® )  \nFilter fit and assembly  \nRemovable sloped  \ndrain pan  \nCopyright  \nThis document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at anytime, and to make changes to its content without obligation to notify any person of such revision or change.  \nTrademarks  \nAll trademarks referenced in this document are the trademarks of their respective owners.  \n©2022 Trane BCX-PRC002A-EN  \nTable of Contents  \nIntroduction ...................................................... 2  \nTrane Blower Coils—Factory Packaged How You Need It... When You Need It ............................................... 2  \nFeatures and Benefits .............................................. 6  \nSingle Source Responsibility ...................................... 6  \nValve Kits ...................................................... 7  \nEnergy Efficiency ................................................ 7  \nControls ....................................................... 7  \nCSTI ........................................................ 7  \nThermostat ................................................... 7  \nTracer® Controller ............................................. 7  \nEnd Devices .................................................. 8  \nFlexibility ...................................................... 8  \nCoil Options .................................................. 8  \nElectric Heat .................................................. 8  \nFilter Placement Options ........................................ 8  \nMotor Options ................................................ 8  \nIndoor Air Quality ............................................... 9  \nFiltration ..................................................... 9  \nAccessibility and Cleanability .................................... 9  \nDrain Pans ................................................... 9  \nVentilation ................................................... 9  \nDehumidification .............................................. 9  \nEasy to Service ................................................ 10  \nOptional Accessory Sections ..................................... 10  \nMixing Box .................................................. 10  \nAngle Filter or Angle Filter/Mixing Box Combination ............... 10  \nBottom (or Top) Access Filter ................................... 11  \nApplication Considerations ......................................... 12  \nSingle-Zone, Constant Volume Applications ........................ 12  \nTwo-Pipe Hydronic Units ...................................... 12  \nTwo-Pipe Hydronic Units With Electric Heat ....................... 12  \nFour-Pipe Hydronic Units ...................................... 13  \nDX Cooling Units ............................................... 13  \nDehumidification ............................................... 13  \nFour-Pipe Unit with Reheat ..................................... 13  \nChilled-Water Reset ........................................... 14  \nLocation and Installation ........................................ 14  \nAcoustics ..................................................... 14  \nOperating Limitations ........................................... 14  \nBCX-PRC002A-EN 3  \nTable of Contents  \nModel Number Description ......................................... 16  \nGeneral Data ..................................................... 18  \nCoil Circuiting ............................................... 25  ","cbCaipfC3ros8uqV","https://ap.wps.com/l/cbCaipfC3ros8uqV","pdf",3756086,76,"English","# Introduction\n## Trane Blower Coils—Factory Packaged How You Need It... When You Need It\n# Features and Benefits\n## Single Source Responsibility\n## Valve Kits\n## Energy Efficiency\n## Controls\n## CSTI\n## Thermostat\n## Tracer® Controller\n# End Devices\n## Flexibility\n## Coil Options\n## Electric Heat\n## Filter Placement Options\n## Motor Options\n## Indoor Air Quality\n# Filtration and Serviceability\n## Filtration\n## Accessibility and Cleanability\n## Drain Pans\n## Ventilation\n## Dehumidification\n## Easy to Service\n## Optional Accessory Sections\n## Mixing Box\n## Angle Filter or Angle Filter/Mixing Box Combination\n## Bottom (or Top) Access Filter\n# Application Considerations\n## Single-Zone, Constant Volume Applications\n## Two-Pipe Hydronic Units\n## Two-Pipe Hydronic Units With Electric Heat\n## Four-Pipe Hydronic Units\n## DX Cooling Units\n## Dehumidification\n## Four-Pipe Unit with Reheat\n## Chilled-Water Reset\n## Location and Installation\n## Acoustics\n## Operating Limitations\n# Model Number, General Data, and Performance\n## Model Number Description\n## General Data\n## Coil Circuiting\n## Performance Data\n## Air Pressure Drop Adjustments\n## Fan arrangements\n## Controls\n## Why Trane Controls?\n## VelociTach™ Motor Control Board\n## Control Options\n## Manual Fan Speed Switch\n## Customer Supplied Terminal Interface (CSTI)\n## Tracer® Controllers\n## Thermostat\n## Tracer® UC400-B Controller\n## Tracer® Controller Features\n## Features Available on All Controllers\n## Additional Features\n## Tracer® Controls Sequence of Operation\n## Air-Fi Wireless Systems\n## Air-Fi Wireless Communications Interface (WCI)\n## Air-Fi Wireless Communications Sensor (WCS)\n## Zone Sensor Options\n## End Device Options\n## Low Temperature Detection\n## Condensate Overflow Detection\n## Outside Air Sensor\n## Discharge Air Sensor\n## Mixing Box Damper Actuator\n## CO2 Sensor for Demand-Controlled Ventilation","[{\"question\":\"Which models are covered in this blower coil product catalog?\",\"answer\":\"The catalog covers Trane blower coil air handler models BCHE and BCVE.\"},{\"question\":\"What airflow range is specified for the single-zone air handler applications?\",\"answer\":\"The document specifies single-zone air handler applications with airflow from 400 to 4000 CFM.\"},{\"question\":\"What filtration and indoor air quality options are highlighted?\",\"answer\":\"The catalog highlights filtration options including an MERV 13 filter option and covers indoor air quality topics such as filtration, ventilation, and dehumidification.\"}]","Blower Coil Air Handler Models BCHE and BCVE - Product Catalog | PDF",192]