[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-381159-105":59,"doc-detail-381159-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","bioinspired-color-near-infrared-endoscopic-imaging-system-for-molecular-guided-cancer-surgery","Bioinspired color-near infrared endoscopic imaging system for molecular guided cancer surgery","","Fluorescently guided minimally invasive surgery improves outcomes and disease-free survival, yet biomarker variability can prevent complete tumor resection when using single molecular probes. This paper presents a bioinspired rigid endoscopic imaging system that captures color images while simultaneously resolving two near-infrared probes, quantifies volumetric ratios in cancer models, and detects tumors in ex vivo samples. Optimized hardware integration includes a hexa-chromatic sensor, NIR-optimized rigid endoscope, and custom illumination fiber bundle. Results show a 60% NIR spatial resolution improvement over a leading FDA-approved endoscope and consistent clinical-like performance.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/bioinspired-color-near-infrared-endoscopic-imaging-system-for-molecular-guided-cancer-surgery/381159/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/bioinspired-color-near-infrared-endoscopic-imaging-system-for-molecular-guided-cancer-surgery/381159.png","ImageObject",300,407,{"name":92,"@type":93},"Riley","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-23","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What problem does the proposed endoscopic system address?","Question",{"text":112,"@type":113},"Single molecular probes can underperform due to biomarker variability, hindering complete tumor resection. The system targets multiple near-infrared probes to improve detection.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How does the imaging system work?",{"text":117,"@type":113},"It is a rigid endoscopic imaging system that captures color images while simultaneously resolving two near-infrared (NIR) probes. It integrates a hexa-chromatic image sensor, an NIR-optimized rigid endoscope, and a custom illumination fiber bundle.",{"name":119,"@type":110,"acceptedAnswer":120},"What improvements and results are reported?",{"text":121,"@type":113},"The optimized system achieves a 60% improvement in NIR spatial resolution versus a leading FDA-approved endoscope. It demonstrates ratio-metric imaging for two tumor-targeted probes in vials and breast cancer animal models, with clinical-like consistency in lung cancer samples.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},381159,1790933840,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":36,"preview_page_count":19,"preview_urls":145},1374391975076,"https://ap-avatar.wpscdn.com/avatar/14000253ca4ec9f6853?x-image-process=image/resize,m_fixed,w_180,h_180&k=1783305029341752051","RESEARCH PAPER  \nBioinspired color-near infrared endoscopic imaging system for molecular guided cancer  \nsurgery  \nMebin B. George  ,a,† Benjamin Lew  ,a,† Steven Blair  ,a Zhongmin Zhu  ,a Zuodong Liang,a Indrajit Srivastava  ,b Austin Chang  ,c Hyungsoo Choi  ,a Kyekyoon Kim  ,a,b,d Shuming Nie  ,b Sunil Singhal  ,c and Viktor Grueva,d,e,*  \naUniversity of Illinois at Urbana Champaign, Department of Electrical and Computer Engineering, Urbana,  \nIllinois, United States  \nbUniversity of Illinois at Urbana-Champaign, Department of Bioengineering, Urbana, Illinois, United States cUniversity of Pennsylvania, Perelman School of Medicine, Department of Thoracic Surgery, Philadelphia,  \nPennsylvania, United States  \ndUniversity of Illinois at Urbana Champaign, Beckman Institute for Advanced Science and Technology, Urbana,  \nIllinois, United States  \neUniversity of Illinois at Urbana-Champaign, Carle Illinois College of Medicine, Urbana, Illinois, United States  \nABSTRACT. Significance: Fluorescently guided minimally invasive surgery is improving patient outcomes and disease-free survival, but biomarker variability hinders complete tumor resection with single molecular probes. To overcome this, we developed abioinspired endoscopic system that images multiple tumor-targeted probes, quantifies volumetric ratios in cancer models, and detects tumors in ex vivo samples.  \nAim: We present a new rigid endoscopic imaging system (EIS) that can capture color images while simultaneously resolving two near-infrared (NIR) probes.  \nApproach: Our optimized EIS integrates a hexa-chromatic image sensor, a rigid endoscope optimized for NIR-color imaging, and a custom illumination fiber bundle.  \nResults: Our optimized EIS achieves a 60% improvement in NIR spatial resolution when compared to a leading FDA-approved endoscope. Ratio-metric imaging of two tumor-targeted probes is demonstrated in vials and animal models of breast cancer. Clinical data gathered from fluorescently tagged lung cancer samples on the operating room’s back table demonstrate a high tumor-to-background ratio and consistency with the vial experiments.  \nConclusions: We investigate key engineering breakthroughs for the single-chip endoscopic system, which can capture and distinguish numerous tumor-targeting fluorophores. As the molecular imaging field shifts toward a multi-tumor targeted probe methodology, our imaging instrument can aid in assessing these concepts during surgical procedures.  \n© The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI. [DOI: 10.1117/1.JBO.28.5.056002]  \nKeywords: endoscopy; multiple fluorophore imaging; fluorescence-guided surgery; bioinspired image sensor; near-infrared contrast agents  \nPaper 230033GR received Feb. 15, 2023; revised May 1, 2023; accepted May 3, 2023; published May  \n26, 2023 .  \n*Address all correspondence to Viktor Gruev, [vgruev@illinois.edu](vgruev@illinois.edu)[ ](vgruev@illinois.edu)†These authors contributed equally to this work.  \nJournal of Biomedical Optics 056002-1 May 2023 • Vol. 28(5)  \nGeorge et al.: Bioinspired color-near infrared endoscopic imaging system. . .  \n1 Introduction  \nEarly detection of solid tumors is of paramount importance for the successful treatment of various types of cancers.1,2 A favorable prognosis can be achieved when localized dysplastic lesions are surgically removed at the earliest onset of the disease. For example, the 5-year post-surgical survival rate for patients diagnosed with early-stage breast and lung cancer is >90% and 70% to 90%, respectively.3,4 In contrast, a drastic decline in survival rates has been reported for patients with advanced-stage cancer (29% for breast and 6% for lung) . With recent developments in miniaturized high-resolution cameras and multimodal optics, endoscopic imaging using white-light il","cbCailQA6Epn1Ur8","https://ap.wps.com/l/cbCailQA6Epn1Ur8","pdf",5626925,16,"English","# Abstract\n# 1 Introduction","[{\"question\":\"What problem does the proposed endoscopic system address?\",\"answer\":\"Single molecular probes can underperform due to biomarker variability, hindering complete tumor resection. The system targets multiple near-infrared probes to improve detection.\"},{\"question\":\"How does the imaging system work?\",\"answer\":\"It is a rigid endoscopic imaging system that captures color images while simultaneously resolving two near-infrared (NIR) probes. It integrates a hexa-chromatic image sensor, an NIR-optimized rigid endoscope, and a custom illumination fiber bundle.\"},{\"question\":\"What improvements and results are reported?\",\"answer\":\"The optimized system achieves a 60% improvement in NIR spatial resolution versus a leading FDA-approved endoscope. It demonstrates ratio-metric imaging for two tumor-targeted probes in vials and breast cancer animal models, with clinical-like consistency in lung cancer samples.\"}]","Bioinspired color-near infrared endoscopic imaging system for molecular guided cancer surgery | PDF",1790243886,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/73bd6bd49b53ac0c8a2a5f0f4a7a0a74.webp",983,1272,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/f91fdc3d053610ca7cbb9cd913822966.webp",982,1270,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/04bee8ca7a3f20f9a66b2991cf03dcd0.webp",981,1269,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/7a88febb9c72fd149192daf0b81606ae.webp",980,1268]