[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-645752-105":59,"doc-detail-645752-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","bevi-electric-motors-installation-and-service-instruction-iec-56-400","BEVI Electric Motors - Installation and Service Instruction - IEC 56-400","","Instruction manual for BEVI asynchronous surface-cooled induction three-phase motors and single-/multiple-speed, including single-phase and series types. Provides IEC 56-400 technical description topics such as enclosure, cooling, insulation, voltage/frequency, terminal box, and motor dewatering, then covers standards, safety information, handling, and installation/commissioning requirements. Includes connection options (DOL, Star/Delta, special ambient situations, frequency inverter operation), startup checklist, maintenance guidance, optional sensors and ventilation/heaters, specific motor data, and troubleshooting references.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/bevi-electric-motors-installation-and-service-instruction-iec-56-400/645752/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/bevi-electric-motors-installation-and-service-instruction-iec-56-400/645752.png","ImageObject",300,407,{"name":92,"@type":93},"Margaret","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-23",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"Which motor types are covered by this manual?","Question",{"text":111,"@type":112},"It covers BEVI asynchronous surface-cooled induction three-phase motors, including single and multiple speed, plus single-phase motors and series types such as Sh, 2SIE, 3SIE, 4SIE, SEMh, 3SSIE, and also 3D, 3D2, 3D3, 3D4.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What are the main safety and handling sections included?",{"text":116,"@type":112},"The manual includes safety information and detailed handling guidance, covering reception, transport and storage, and lifting of motors.",{"name":118,"@type":109,"acceptedAnswer":119},"What connection methods and operating conditions are addressed?",{"text":120,"@type":112},"It provides direct-on-line (DOL) start, Star/Delta (Y/D) start, frequency inverter operation, and guidance for special ambient situations including ambient temperature, altitude, and different supply.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},645752,1792734065,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":36,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":142},137451207643,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","BEVI Electric motors, IEC 56-400  \nInstallation and service instruction  \nEvery care has been taken to ensure the accuracy of the information contained in this publication.  \nDue to BEVI’s policy of continuous development and improvement, BEVI reserves the right to supply products which may differ slightly from those illustrated and described in this manual.  \nDescriptions and technical features listed in this manual may not to be considered as binding. Under no circumstances should be considered as a contractual obligation.  \nThe data in this manual may change without prior notice.  \nTable of content  \n1 Technical description ..................................4  \n1.1 General ...................................................4  \n1.2 Enclosure ................................................4  \n1.3 Cooling ....................................................4  \n1.4 Insulation ................................................4  \n1.5 Voltage and frequency ............................4  \n1.6 Surface.................................................... 5  \n1.7 Terminal box and terminals .................... 5  \n1.8 Motor dewatering (drain holes) ............... 5  \n2 Standards and directive...............................5  \n3 Safety information ........................................6  \n4 Handling ........................................................6  \n4.1 Reception of motor .................................6  \n4.2 Transport and storage ............................6  \n4.3 Lifting of motors ......................................6  \n5 Installation and commissioning..................7  \n5.1 General ................................................... 7  \n5.2 Foundation .............................................. 7  \n5.3 Bearings .................................................. 7  \n5.4 Insulation resistance ............................... 7  \n5.5 Distance for cooling ................................ 7  \n5.6 Balancing ................................................ 7  \n5.7 Mounting of the motor .............................8  \n5.7.1 Coupling drives ............................8  \n5.7.2 Belt drives ....................................8  \n5.7.3 Drain plugs...................................8  \n5.8 Electrical connection ...............................8  \n6 Connecting options ......................................9  \n6.1 Direct on-line (DOL) start ........................9  \n6.2 Star/Delta (Y/D) start ..............................9  \n6.3 Output from motor during special ambient situations.......................................................... 9  \n6.3.1 Ambient temperature ...................9  \n6.3.2 Altitude .........................................9  \n6.3.3 Different supply ..........................10  \n6.4 Frequency inverter operation ................ 10  \n6.4.1 Motor cooling ............................. 11  \n6.4.2 Thermal protection .....................11  \n6.4.3 Bearing currents ........................ 11  \n6.4.4 EMC and cables ........................ 11  \n7 Checklist at motor start-up........................12  \n8 Maintenance ................................................12  \n8.1 Service of motor during operation ........ 12  \n8.2 Periodical inspections ........................... 13  \n8.3 Bearings and lubrication – general ....... 13  \n9 Options ........................................................14  \n9.1 Thermocontacts .................................... 14  \n9.2 Thermistors (PTC) ................................ 14  \n9.3 PT100 sensors ...................................... 15  \n9.4 Forced ventilation (IC416) .................... 15  \n9.5 Anti-condensation heaters .................... 15  \n9.6 Motor winding anti-condensation ......... 16  \n9.7 Mechanical brake .................................. 16  \n10 Specific motor data ................................... 17  \n10.1 Exploded views ..................................... 17  \n10.2 Tightening torque .................................. 18  \n10.3 Type Sh, 2SIE, 3S","cbCaicTNq2XBLFyv","https://ap.wps.com/l/cbCaicTNq2XBLFyv","pdf",2093654,"English","# Technical description\n## General\n## Enclosure\n## Cooling\n## Insulation\n## Voltage and frequency\n## Surface\n## Terminal box and terminals\n## Motor dewatering (drain holes)\n# Standards and directive\n# Safety information\n# Handling\n## Reception of motor\n## Transport and storage\n## Lifting of motors\n# Installation and commissioning\n## Foundation\n## Bearings\n## Insulation resistance\n## Distance for cooling\n## Balancing\n## Mounting of the motor\n# Connecting options\n## Direct on-line (DOL) start\n## Star/Delta (Y/D) start\n## Frequency inverter operation\n# Checklist at motor start-up\n# Maintenance\n# Options\n# Specific motor data\n# Troubleshooting","[{\"question\":\"Which motor types are covered by this manual?\",\"answer\":\"It covers BEVI asynchronous surface-cooled induction three-phase motors, including single and multiple speed, plus single-phase motors and series types such as Sh, 2SIE, 3SIE, 4SIE, SEMh, 3SSIE, and also 3D, 3D2, 3D3, 3D4.\"},{\"question\":\"What are the main safety and handling sections included?\",\"answer\":\"The manual includes safety information and detailed handling guidance, covering reception, transport and storage, and lifting of motors.\"},{\"question\":\"What connection methods and operating conditions are addressed?\",\"answer\":\"It provides direct-on-line (DOL) start, Star/Delta (Y/D) start, frequency inverter operation, and guidance for special ambient situations including ambient temperature, altitude, and different supply.\"}]","BEVI Electric Motors - Installation and Service Instruction - IEC 56-400 | PDF",101]