[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-354199-105":59,"doc-detail-354199-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","bandgap-enabled-ultrasound-tissue-marking-by-a-biodegradable-metastructured-hydrogel-implant","Bandgap-enabled ultrasound tissue marking by a biodegradable metastructured hydrogel implant","","Biodegradable metastructured hydrogel tissue markers are proposed to overcome conventional ultrasound marker limits, including nonspecificity, low resolution, poor biodegradability, and inadequate biocompatibility. The implant integrates acoustic bandgaps to produce specific ultrasonic reflection spectra and enables visualization through frequency-to-color mapping on B-mode images, supporting scalable distinction of multiple markers. Delivery uses an 18-gauge puncture needle and incorporates tissue-mimicking softness to reduce displacement, damage, and inflammation. Live pig and rat studies verify clear identification, dynamic stability, long-term marking ability, and biocompatibility for breast cancer therapy guidance.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/bandgap-enabled-ultrasound-tissue-marking-by-a-biodegradable-metastructured-hydrogel-implant/354199/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/bandgap-enabled-ultrasound-tissue-marking-by-a-biodegradable-metastructured-hydrogel-implant/354199.png","ImageObject",300,407,{"name":92,"@type":93},"Cart","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-09-22",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",16,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"Why are conventional ultrasound tissue markers difficult to identify?","Question",{"text":113,"@type":114},"Conventional markers suffer from nonspecificity and low spatial resolution in B-mode ultrasound, causing rigid markers to appear blurred. Limited frequency specificity also allows other high-echo tissues to interfere, making identification dependent on clinician experience.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What is the proposed metastructured hydrogel marker designed to achieve?",{"text":118,"@type":114},"The marker uses acoustic bandgaps to generate specific ultrasonic reflection spectra, enabling visualization via frequency-to-color mapping on B-mode images. Scalable designs allow multiple markers to be distinguished.",{"name":120,"@type":111,"acceptedAnswer":121},"How is the implant delivered and what benefits does it provide?",{"text":122,"@type":114},"The metastructured hydrogel marker is delivered via an 18-gauge puncture needle and features tissue-mimicking softness. This mitigates displacement risks and reduces tissue damage and inflammation, with in vivo studies supporting identification and long-term stability.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},354199,1790212045,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":41,"preview_page_count":19,"preview_urls":146},18829141979164,"https://eur-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","APPLIED SCIENCES AND ENGINEERING  \nBandgap-enabled ultrasound tissue marking by a biodegradable metastructured hydrogel implant  \nZhangqi Pan1, Lejie Qin1, Bo Gao1, Na Li1, Yizhou Huang1, Yuchen Zhou1, Mengyuan Zhou1, Yibo Huang1, Jie Chen1, Wei Wang1, Yue Lian1, Zeqing Cai1, Hanchuan Tang1*, Jianfeng Zang1,2*  \nImplantation of tissue markers within lesions is standard practice in breast cancer diagnosis and treatment, which provides critical guidance for regular follow-up and precise surgical localization. However, the identification of existing markers is limited by nonspecificity and low resolution of conventional ultrasound imaging. The use of rigid materials to compensate for this constraint has resulted in inadequate biodegradability and biocompatibility. Here, we propose a biodegradable metastructured hydrogel tissue marker with acoustic bandgaps enabling specific ultrasonic reflection spectra. Through frequency-to-color mapping on B-mode images, visualization is achieved, with scalable designs allowing multiple marker distinction. Deliverable via an 18-gauge puncture needle and featuring tissue-mimicking softness, the metagel marker mitigates displacement risks, tissue damage, and inflammation. Live pig experiments demonstrate clear identification and dynamic stability. Six-week rat studies confirm long-term marking ability and biocompatibility. These results support the metagel marker’s clinical potential for breast cancer management and precise therapy.  \ncopyright © 2026 the Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. no claim to original U.S.  \nGovernment Works. distributed under a creative commons Attribution noncommercial license 4.0 (cc BY-nc) .  \nINTRODUCTION  \nBreast cancer constitutes the most prevalent female malignancy, representing 30% of all cancers in women with >2 million annual incident cases globally (1–5) . Regular imaging surveillance enables long-term lesion management and timely intervention, substantially reducing mortality (4, 5). In this process, tissue marker placement in biopsied lesions facilitates precise localization during tumor progression, allowing the tracking of morphological changes while preventing repeat biopsies and secondary trauma (6–9) . Moreover, this approach improves surgical margin assessment, increasing negative margin rates from 30 to 90%( 10–12) . These capabilities establish tissue marking as the standard of care for precision therapy in breast cancer (6–8) .  \nCurrent tissue markers must be made from materials with high modulus and high density, such as metals or ceramics. This is determined by the nature of B-mode grayscale ultrasound imaging: Rigid materials enhance the amplitude of reflected sound waves to achieve high contrast with soft tissues. Nevertheless, the structural details of these rigid markers designed with distinct shapes are often indiscernible in ultrasound imaging due to its relatively lower spatial resolution compared to x-ray and magnetic resonance imaging (MRI), causing them to appear as blurred areas in the ultrasound image. This issue is compounded by B-mode ultrasound’s inherent lack of frequency specificity (13), which allows any high-echo tissue to cause interference. Consequently, identification becomes highly dependent on physician experience, prompting the intentional design of larger markers (typically ~5 mm in length) to facilitate shape characterization—a design necessity that, however, increases implantation risks ( 14–16). Moreover, rigid markers for strong ultrasonic reflection sacrifice biocompatibility and biodegradability. Although flexible polymers are explored for coating of metallic  \n1School of integrated circuits and Wuhan national laboratory for Optoelectronics, huazhong University of Science and technology, Wuhan, china. 2the State Key laboratory of intelligent Manufacturing equipment and technology, huazhong University of Science and technology, Wuhan, china.  \n*co","cbCaickhbYGolL7j","https://ap.wps.com/l/cbCaickhbYGolL7j","pdf",2324414,12,"English","# Introduction\n## Tissue marker placement and clinical need\n## Limitations of conventional rigid markers in B-mode ultrasound\n## Acoustic-parameter-based imaging modalities and their gaps\n## Bandgap metastructured materials as a solution","[{\"question\":\"Why are conventional ultrasound tissue markers difficult to identify?\",\"answer\":\"Conventional markers suffer from nonspecificity and low spatial resolution in B-mode ultrasound, causing rigid markers to appear blurred. Limited frequency specificity also allows other high-echo tissues to interfere, making identification dependent on clinician experience.\"},{\"question\":\"What is the proposed metastructured hydrogel marker designed to achieve?\",\"answer\":\"The marker uses acoustic bandgaps to generate specific ultrasonic reflection spectra, enabling visualization via frequency-to-color mapping on B-mode images. Scalable designs allow multiple markers to be distinguished.\"},{\"question\":\"How is the implant delivered and what benefits does it provide?\",\"answer\":\"The metastructured hydrogel marker is delivered via an 18-gauge puncture needle and features tissue-mimicking softness. This mitigates displacement risks and reduces tissue damage and inflammation, with in vivo studies supporting identification and long-term stability.\"}]","Bandgap-enabled ultrasound tissue marking by a biodegradable metastructured hydrogel implant | PDF",1790109439,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/45f98e9ccac03ee7cd124ebc7d7f4762.webp",983,1250,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/f10e808741ee8f25446bfa6de870795d.webp",982,1249,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ce455d476be2ce8a822851df953e3dde.webp",981,1248,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/18a895b3466713ed41192400e462a2d2.webp",980,1247]