[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-677177-105":59,"doc-detail-677177-en":129},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":122,"head_meta":124,"extra_data":126,"updated_unix":128},105,"en","balboa-water-group-bp6013g2-tech-sheet-system-revision-history","Balboa Water Group BP6013G2 Tech Sheet - System Revision History","","BP6013G2 tech sheet provides product configuration references and operating software details for Balboa Water Group heaters and spa control system models. It lists customer part numbers for multiple heater variants (Incoloy and Titanium, including “3S” and different kW ratings), CE system model identifiers for 2.0kW and 3.0kW, software version IDs, control panel requirements for spaTouch™2 and TP600/TP400/TP800/TP900 menus, and notes on bba™ and bba™2 Bluetooth Amp integration. It also includes system power requirements, HiPot testing instructions, and a revision history mapping part numbers to engineering project numbers and change dates.",{"@graph":69,"@context":121},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/balboa-water-group-bp6013g2-tech-sheet-system-revision-history/677177/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/balboa-water-group-bp6013g2-tech-sheet-system-revision-history/677177.png","ImageObject",300,407,{"name":92,"@type":93},"Mabel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":101,"interactionType":102,"userInteractionCount":8},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117],{"name":108,"@type":109,"acceptedAnswer":110},"What software and control panel versions are required for spaTouch™2 and bba™/CHROMAZON3™ support?","Question",{"text":111,"@type":112},"The sheet specifies version thresholds for spaTouch™2 and indicates that spaTouch™2 version 2.0+ is required for fully integrated bba™2 functionality and that spaTouch™ version 3.36+ is required for bba™ support. It also lists TP900/TP800 version requirements for bba™/bba™2 integration depending on the menu and feature set.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"How should HiPot testing be performed to avoid false failures?",{"text":116,"@type":112},"Disconnect the slip terminal with green wires from J11 before performing the HiPot test, and reconnect it to J11 after the test completes successfully. Failure to disconnect may cause a false failure.",{"name":118,"@type":109,"acceptedAnswer":119},"What are the power service requirements and key circuit breaker notes for 1-service and 3-service?",{"text":120,"@type":112},"For single service, use 230VAC 50/60Hz with 3 wires and a 32A rating (circuit breaker maximum 40A). For 3-service, use 230VAC line-to-neutral 50/60Hz with 5 wires and 16A per phase line (circuit breaker maximum 20A each phase line), and ensure service includes a neutral wire at 230VAC.","https://schema.org",{"og:url":83,"og:type":123,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":125,"canonical":83},"index,follow",{"doc_id":127,"site_id":62},677177,1793777776,{"code":4,"msg":5,"data":130},{"doc_id":127,"user_id":131,"nickname":92,"user_avatar":132,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":41,"language":138,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":139,"faqs":140,"seo_title":141,"seo_description":67,"update_tm":128,"read_time":142},7971474920318,"https://ap-avatar.wpscdn.com/avatar/74000ee537e6b0ca360?x-image-process=image/resize,m_fixed,w_180,h_180&k=1788430171632181674","BP6013G2 Tech Sheet  \nCustomer:  \nPart Number:  \nCustom Box Overlay Box Overlay Part Number  \nBalboa Water Group  \n59126 825 Incoloy 3.0kW  \n59390 825 Incoloy 3.0kW “3S” heater 56827-03 Titanium 3.0kW  \n59414 Titanium 3.0kW “3S” heater  \n59391 825 Incoloy 2.0kW □  \nN/A  \nCE System Model For 3.0kW: BP21-BP6013G2-RCA3.0K  \nCE System Model For 2.0kW: BP21-BP6013G2-RCA2.0K  \nSoftware Version ID: M100_226 V43 .0  \nSoftware Version: 43.0  \nFile Name: BP6013_43.0_BP6013G2 . hex  \nConfiguration Signature: F71FE5EB  \nEng. Project Number: 5328  \nControl Panels:  \nspaTouch™2 Any version (version 2.0 or later required for bba™2 fully integrated functionality; version 2.19 or later required for CHROMAZON3™ support) Icon spaTouch™ Any version (version 3.36 or later required for bba™2 fully integrated functionality)  \nMenued spaTouch™ Any version (version 2.8 or later required for bba™2 integrated functionality) TP900 Version 3.1 and later (Version 3.13 or later required for bba™)  \nTP800 Version 3.1 and later (Version 3.13 or later required for bba™; version 4.11 or later required for bba™2 integrated functionality)  \nTP600 Version 2.7 and later (Version 2.12 or later required for bba™/bba™2 On/Off control via menu)  \nTP400T CE Version 2.7 and later (TP400T US should not be used) (Version 2.12 or later required for bba™/bba™2 On/Off control via menu)  \nManufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,  \nCanadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.  \nTemplate 56377 10-05-12 1 56827-03_59126_59390_59391_59414_97_D 01-09-20    \nSystem  \nRevision History  \n\n| Part \\# | EPN | Date | Originator | Changes Made |\n| --- | --- | --- | --- | --- |\n| ZT000254 | 4697 | 03-17-16 | BWG | BP6013 system with expander board and no splitter. |\n| 56826\u003Cbr>56827 | 4697 | 05-02-16 | BWG | Release to production. |\n| 56826-01\u003Cbr>56827-01 | 4776 | 10-19-16 | BWG | Updated to latest software version, adding topside-intergrated bba™2 support. Released to production. |\n| 56826-02\u003Cbr>56827-02 | 4890 | 05-31-17 | BWG | Updated to latest software version, adding bba™/bba™2 On/Off support to TP600/TP400 Menus. Also corrections to wiring diagram. Released to production. |\n| 56978 | N?A | 06-04-18 | BWG | Add 2kW 800 Inc system PN. |\n| 56826-03\u003Cbr>56827-03\u003Cbr>56978-01 | 5098 | 12-11-18 | BWG | Redesigned BP6013 board. + updated software to support CHROMAZON3™ & M8 . |\n| 59126 | N/A | 06-17-19 | BWG | Add 3kW 825 Inc system PN. |\n| 59390\u003Cbr>59391 | 5302 | 11-25-19 | BWG | Add 3.0kW 825 Incoloy “3S” system PN and 2.0kW 825 Incoloy system PN. 800 Incoloy system PNs 56826-XX and 56978-XX discontinued. |\n| 59414 | 5328 | 01-09-20 | BWG | Add 3.0kW Titanium “3S” system PN. |\n|  |  |  |  |  |\n\nbba™ & bba™2 (Balboa Bluetooth Amp) connection is documented seperately.  \nbba™ is integrated into graphic display panels (TP800, TP900 and spaTouch™) . With TP600/TP400, use the “BT” entry on the menu to toggle bba™ power On/Off. bba™2 is integrated into graphic display panels (TP800, TP900 and spaTouch™) . With TP600/TP400, use the “BT” entry on the menu to toggle bba™2 power On/Off.  \nManufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,  \nCanadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2014 Balboa Water Group.  \nTemplate 56377 10-05-12 2 56827-03_59126_59390_59391_59414_97_D 01-09-20    \nBasic Functions Setup 1-12  \nPower Requirements:  \nSingle Service [3 wires (line, neutral, ground)]  \n230VAC, 50/60Hz*, 1þ, 32A,(Circuit Breaker rating = 40A max.) Dual Service N/A  \n3-Service [5 wires (line 1, line 2, line 3, neutral, ground)]  \n230VAC line-to-neutral","cbCaieIoOW2K5gQP","https://ap.wps.com/l/cbCaieIoOW2K5gQP","pdf",2373559,"English","# System Revision History\n## Configuration and software/version references\n## Control panel and menu requirements for bba™/bba™2\n## Power requirements and HiPot testing notes","[{\"question\":\"What software and control panel versions are required for spaTouch™2 and bba™/CHROMAZON3™ support?\",\"answer\":\"The sheet specifies version thresholds for spaTouch™2 and indicates that spaTouch™2 version 2.0+ is required for fully integrated bba™2 functionality and that spaTouch™ version 3.36+ is required for bba™ support. It also lists TP900/TP800 version requirements for bba™/bba™2 integration depending on the menu and feature set.\"},{\"question\":\"How should HiPot testing be performed to avoid false failures?\",\"answer\":\"Disconnect the slip terminal with green wires from J11 before performing the HiPot test, and reconnect it to J11 after the test completes successfully. Failure to disconnect may cause a false failure.\"},{\"question\":\"What are the power service requirements and key circuit breaker notes for 1-service and 3-service?\",\"answer\":\"For single service, use 230VAC 50/60Hz with 3 wires and a 32A rating (circuit breaker maximum 40A). For 3-service, use 230VAC line-to-neutral 50/60Hz with 5 wires and 16A per phase line (circuit breaker maximum 20A each phase line), and ensure service includes a neutral wire at 230VAC.\"}]","Balboa Water Group BP6013G2 Tech Sheet - System Revision History | PDF",76]