[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-664117-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-664117-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","axis-fire-alarm-panels-product-manual-specifications-5000-050-04-and-later","Axis Fire Alarm Panels - Product Manual - Specifications (5000-050-04 and later)","","Axis fire alarm panel product manual outlining operation and functions available from Software Version 5000-050-04 onward. Provides detailed technical specifications for multiple panel models (Axis-5100, Axis-5200, Axis-5400, Axis-5800), including enclosure type, dimensions and weight, environmental limits (temperature, humidity), cable entry counts, AC supply ratings, battery capacity and charging current, power supply output ranges, ripple and electrical characteristics, loop and fire-zone capacities, supported devices per loop, sounder, relay, auxiliary outputs, display type, programmable inputs, USB/RS232, networking options, and event-log capacity. Includes standards, cautions, warnings, description, and series sectioning.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/axis-fire-alarm-panels-product-manual-specifications-5000-050-04-and-later/664117/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/axis-fire-alarm-panels-product-manual-specifications-5000-050-04-and-later/664117.png","ImageObject",300,407,{"name":42,"@type":43},"noah","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"From which software version does the manual’s described operation and functions apply?","Question",{"text":62,"@type":63},"The described operation and functions are available from Software Version 5000-050-04 onwards.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What environmental limits are specified for the Axis fire alarm panels?",{"text":67,"@type":63},"The specifications list temperature range of -5°C to 40°C and relative humidity up to 95% max.",{"name":69,"@type":60,"acceptedAnswer":70},"How many fire zones and loops can the Axis-5800 support?",{"text":71,"@type":63},"Axis-5800 supports 400 max fire zones across 8 loops (2x 4 loops), with networked operation up to 2000 when networked.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},664117,1793240096,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},1099529839121,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Fire Alarm Panels  \nProduct Manual  \nThe operation and functions described in this manual are available from Software Version 5000-050-04 onwards.  \nSpecifications:  \n| Item | Specification Details |  |  |  |\n| --- | --- | --- | --- | --- |\n| Part Number: | Axis-5100 | Axis-5200 | Axis-5400 | Axis-5800 |\n| Enclosure | Steel IP30 RAL7035 | Steel IP30 RAL7035 | Steel IP30 RAL7035 | Steel IP30 RAL7035 |\n| Dimensions H x W x D mm | 345 x 345 x 85 (/M) 345 x 430 x 120\u003Cbr>(/L) 475 x 450 x 120\u003Cbr>(/D) 475 x 450 x 190 | 345 x 430 x 120\u003Cbr>(/L) 475 x 450 x 120\u003Cbr>(/D) 475 x 450 x 190 | 475 x 450 x 120\u003Cbr>(/D) 475 x 450 x 190\u003Cbr>(/E) 750 x 450 x 190 | 750 x 450 x 190 |\n| Weight (excluding batteries) | 6Kg (/M) 8Kg\u003Cbr>(/L) 10Kg\u003Cbr>(/D) 12kg | 8Kg\u003Cbr>(/L) 10Kg\u003Cbr>(/D) 12Kg | 10Kg (/D) 12Kg\u003Cbr>(/E) 18kg | 20Kg |\n| 19” Rack\u003Cbr>Dimensions H x W x D mm Module\u003Cbr>MXM-510-16U (22Kg)\u003Cbr>MXM-510-20U (25Kg) | (/R) 266 x 482 x 125\u003Cbr>730 x 535 x 230\u003Cbr>910 x 535 x 230 | (/R) 266 x 482 x 125\u003Cbr>730 x 535 x 230\u003Cbr>910 x 535 x 230 | (/R) 266 x 482 x 125\u003Cbr>730 x 535 x 230\u003Cbr>910 x 535 x 230 |  |\n| Temperature | -5°C to 40°C | -5°to 40°C | -5°C to 40°C | -5°C to 40°C |\n| Humidity (RH) | 95 % Max | 95 % Max | 95 % Max | 95 % Max |\n| Cable Entries (20mm knockouts) | 13x top / 8x top rear (/M) 17x top / 11x top rear / 2 bottom\u003Cbr>(/L) 19x top / 11x top rear / 2 bottom\u003Cbr>(/D) 30x top / 11x top rear / 3 bottom | 17x top / 11x top rear / 2 bottom (/L) 19x top / 11x top rear / 2 bottom\u003Cbr>(/D) 30x top / 11x top rear / 3 bottom | 19x top / 11x top rear / 2 bottom (/D) 30x top / 11x top rear / 3 bottom\u003Cbr>(/E) 30x top / 6x top rear / 3 bottom plus 2x double knockout rear | 30x top / 6x top rear / 3 bottom plus 2x double knockout rear |\n| AC Supply\u003Cbr>(ratings marked on label inside panel – see section 2.1 for location) | 200-240V\u003Cbr>50–60 Hz\u003Cbr>1.4A max | 200-240V\u003Cbr>50–60 Hz\u003Cbr>1.4A max | 200-240V\u003Cbr>50–60 Hz\u003Cbr>1.4A max | 200-240V\u003Cbr>50–60 Hz\u003Cbr>2.8A max |\n| Battery Capacity | 24V 4Ah Internal (min)\u003Cbr>24V 7Ah Internal (max)(/M) 24V 12Ah Internal (max)\u003Cbr>(/L) 24V 18Ah Internal (max)\u003Cbr>(/D) 24V 24Ah Internal (max) | 24V 4Ah Internal (min)\u003Cbr>24V 12Ah Internal (max)(/L) 24V 18Ah Internal (max)\u003Cbr>(/D) 24V 45Ah Internal (max) | 24V 4Ah Internal (min)\u003Cbr>24V 18Ah Internal (max)(/D) 24V 45Ah Internal (max)\u003Cbr>(/E) 24V 45Ah Internal (max) | 2x 24V 4Ah Internal (min) 2x 24V 18Ah Internal (max) OR\u003Cbr>1x 24V 45Ah Internal (max) / 1x 24V 45Ah External (max) |\n| Charging Current | 1.0A Temp Compensated | 2.0A Temp Compensated | 2.0A Temp Compensated | 2x 2 .0A Temp Compensated |\n| Power Supply | On-board 24V DC, 3A High Efficiency Off-Line Switched Mode | On-board 24V DC, 5A High Efficiency Off-Line Switched Mode | On-board 24V DC, 5A High Efficiency Off-Line Switched Mode | 2x On-board 24V DC, 5A High Efficiency Off-Line Switched Mode |\n| Output Voltage1 | 18.0V – 28.0V | 18.0V – 28.0V | 18.0V – 28.0V | 18.0V – 28.0V |\n| Ripple (Vpkpk) | 1.0V | 1.0V | 1.0V | 1.0V |\n| Max Battery Ohms | 1.6Ω ± 0.1 Ω | 0.8Ω ± 0.1 Ω | 0.8Ω ± 0.1 Ω | 0.8Ω ± 0.1 Ω |\n| Imax(a)/\u003Cbr>Imax(b)2 | 1.6A 3.0A | 2.6A 5.0A | 2.6A 5.0A | 2.6A\u003Cbr>5.0A (per chassis) |\n| Number of Fire Zones | 200 max (2000 when networked) | 200 max, across 2 loops\u003Cbr>(2000 when networked) | 200 max, across 4 loops\u003Cbr>(2000 when Networked) | 400 max, across 8 loops (2x 4 loops) (2000 when Networked) |\n| Number of Loops | 1 | 1-2 | 1 to 4 | 2 to 8 (2x 1 to 4) |\n| Loop Current 3 | 500mA max. 500mA max. per Loop 500mA max. per Loop 500mA max. per Loop |  |  |  |\n| Devices per Loop | 240 detector/call points per loop (max)– MXP-502 (or MXP-568)\u003Cbr>VdS\u003Cbr>2095\u003Cbr>Clause 6.2.5 Not more than 128 devices per loop\u003Cbr>VdS\u003Cbr>2095\u003Cbr>Not more than 512 devices per panel or 12000m2 |  |  |  |\n| Protocols | Advanced AV |  |  |  |\n| Sounder Outputs 3 | 2 x 1A Programmable | 2 x 1A Programmable | 4 x 1A Programmable | 8 (2x4) x 1A Programmable |\n| Relay Outputs (Programmable) | 2 x1A 30VAC/DC (max) 10mA 5V (min) | 2 x 1A 30V AC/DC (ma","cbCaiuW2GI7xV9qH","https://ap.wps.com/l/cbCaiuW2GI7xV9qH","pdf",2885501,84,"English","# 1 Introduction\n## 1.1 Standards\n## 1.2 Cautions and Warnings\n## 1.3 Description\n## 1.3.1 5000V Series","[{\"question\":\"From which software version does the manual’s described operation and functions apply?\",\"answer\":\"The described operation and functions are available from Software Version 5000-050-04 onwards.\"},{\"question\":\"What environmental limits are specified for the Axis fire alarm panels?\",\"answer\":\"The specifications list temperature range of -5°C to 40°C and relative humidity up to 95% max.\"},{\"question\":\"How many fire zones and loops can the Axis-5800 support?\",\"answer\":\"Axis-5800 supports 400 max fire zones across 8 loops (2x 4 loops), with networked operation up to 2000 when networked.\"}]","Axis Fire Alarm Panels - Product Manual - Specifications (5000-050-04 and later) | PDF",212]