[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663182-105":59,"doc-detail-663182-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","axis-a16-network-door-controller-series-electrical-wiring-drawings","AXIS A16 Network Door Controller Series - Electrical wiring drawings","","AXIS A16 Network Door Controller Series electrical wiring drawings provide guidance for installing door controllers with locally powered reader and RS485 reader data wiring. The material covers supported reader cable lengths, typical requirements such as twisted pair with shield and 120 ohm impedance, and recommended wire gauge AWG 28-16. It includes example connection scenarios for long runs, single-door installations, and multi-drop OSDP reader configurations, emphasizing compliance with local life safety codes and correct power and relay ratings.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/axis-a16-network-door-controller-series-electrical-wiring-drawings/663182/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/axis-a16-network-door-controller-series-electrical-wiring-drawings/663182.png","ImageObject",300,407,{"name":92,"@type":93},"Kyle","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What wiring requirements are specified for the reader data connection?","Question",{"text":112,"@type":113},"Use RS485 communication only and twisted pair with shield. The document also specifies AWG 28-16 and 120 ohm impedance.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the recommended maximum cable length for an OSDP reader powered locally?",{"text":117,"@type":113},"The drawings state up to 1000 m (3281 ft) for locally powered reader installation, and also show alternative examples where the reader cable is longer than the recommended 150 m (500 ft).",{"name":119,"@type":110,"acceptedAnswer":120},"How should a one-door setup be configured in AXIS Camera Station?",{"text":121,"@type":113},"Add a door, connect it to a door controller, select the appropriate relay port for the lock, add a door monitor to I/O 5, add an OSDP reader on door side A to Reader port 1, and add a REX device on door side B to I/O 6.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663182,1793225657,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},3985741905716,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","AXIS A16 Network Door Controller Series  \nElectrical wiring drawings  \nElectrical wiring drawings  \nAXIS A16 Network Door Controller Series © Axis Communications AB, 2021-2026 Date: January 2026  \nInstallation with long cable for OSDP reader  \nPowered locally  \nReader Power Supply  \nUp to 1000 m (3281 ft)  \n|  | BA + |\n| --- | --- |\n|  |  |\n|  |  |\n|  |  |\n\nCommon ground  \nApplication  \nReader cable is longer than recommended 1000 m (3281 ft)  \nRequirements  \n> Reader powered locally, not by controller> Reader data wiring  \n> RS485 cable, only RS485 communication in cable> Twisted pair with shield  \n> AWG 28-16  \n> 120 ohm impedance  \nAdhere to local life safety code in all installations.  \nIllustration does not depict door monitors, REX devices, locks, controller power supply, network switch, DC power backup and UPS.  \nEnsure that your power supplies and relays are rated for the intended purposes.  \nThis is just an example. Always refer to the pin chart provided from AXIS Camera Station or 3rd party access control management system for installation. Electrical wiring drawings / AXIS A16 Network Door Controller Series / © Axis Communications AB, 2021-20246 / January 2026  \nApplication  \nReader cable is longer than recommended 150 m (500 ft)  \nRequirements  \n> Reader powered locally, not by controller> Reader data wiring  \n> See reader speci cation for cable requirements  \nAdhere to local life safety code in all installations.  \nIllustration does not depict door monitors, REX devices, locks, controller power supply, network switch, DC power backup and UPS.  \nEnsure that your power supplies and relays are rated for the intended purposes.  \nThis is just an example. Always refer to the pin chart provided from AXIS Camera Station or 3rd party access control management system for installation. Electrical wiring drawings / AXIS A16 Network Door Controller Series / © Axis Communications AB, 2021-2026 / January 2026  \nApplication  \nInput cable is longer than recommended 200 m (656 ft)  \nRequirements  \n> AWG 28-16  \nAdhere to local life safety code in all installations.  \nIllustration does not depict door monitors, REX devices, locks, controller power supply, network switch, DC power backup and UPS.  \nEnsure that your power supplies and relays are rated for the intended purposes.  \nThis is just an example. Always refer to the pin chart provided from AXIS Camera Station or 3rd party access control management system for installation. Electrical wiring drawings / AXIS A16 Network Door Controller Series / © Axis Communications AB, 2021-2026 / January 2026  \nInstallation with one door  \nApplication  \nStandard one-door installation with con guration in AXIS Camera Station  \nConsiderations  \n> 12 or 24 V fail-secure lock  \n> PoE Class 4 switch  \n> All peripheral consumption within the controller's power budget  \nAXIS Camera Station conﬁguration  \n1. Add a door  \n2. Connect to a door controller  \n3. Select Relay 1 for the rst lock  \nLocks  \nRelay port 1   \nNot connected   \n4. Add a door monitor and assign it to I/O 5  \nDoor monitor   \n I/O 5  \n5. Add an OSDP reader on door side A and assign it to Reader port 1  \nReader   \nGeneral  \nAdvanced  \n Reader port 1 on device card  \n Reader port 2 on device card  \n OSDP RS485  \n6. Add a REX device on door side B and assign it to I/O 6  \nREX device   \nAdhere to local life safety code in all installations. Illustration does not depict DC power backup and UPS.  \nEnsure that your power supplies and relays are rated for the intended purposes.  \nI/O 5  \n I/O 6  \nThis is just an example. Always refer to the pin chart provided from AXIS Camera Station or 3rd party access control management system for installation. Electrical wiring drawings / AXIS A16 Network Door Controller Series / © Axis Communications AB, 2021-2026 / January 2026  \nAdhere to local life safety code in all installations.  \nIllustration does not depict door monitors, REX devices, locks, DC power backup and UPS.  \nEnsure that your power supplie","cbCaisutD4uZl1Lm","https://ap.wps.com/l/cbCaisutD4uZl1Lm","pdf",7074066,14,"English","# Electrical wiring drawings\n## Installation with long cable for OSDP reader\n## Installation with one door (AXIS Camera Station configuration)\n## Adding an OSDP reader and a REX device\n## Reader options and possible OSDP reader configurations\n## Two OSDP readers (multi-drop) for the controller","[{\"question\":\"What wiring requirements are specified for the reader data connection?\",\"answer\":\"Use RS485 communication only and twisted pair with shield. The document also specifies AWG 28-16 and 120 ohm impedance.\"},{\"question\":\"What is the recommended maximum cable length for an OSDP reader powered locally?\",\"answer\":\"The drawings state up to 1000 m (3281 ft) for locally powered reader installation, and also show alternative examples where the reader cable is longer than the recommended 150 m (500 ft).\"},{\"question\":\"How should a one-door setup be configured in AXIS Camera Station?\",\"answer\":\"Add a door, connect it to a door controller, select the appropriate relay port for the lock, add a door monitor to I/O 5, add an OSDP reader on door side A to Reader port 1, and add a REX device on door side B to I/O 6.\"}]","AXIS A16 Network Door Controller Series - Electrical wiring drawings | PDF",35]