[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646474-105":59,"doc-detail-646474-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","aveir-dr-dual-chamber-leadless-pacemaker-system-mri-guide-step-by-step-instructions-for-assessment-and-programming","AVEIR DR Dual Chamber Leadless Pacemaker System MRI Guide - Step-by-Step Instructions for Assessment and Programming","","AVEIR DR dual chamber leadless pacemaker system MRI guide provides step-by-step instructions for cardiac clinicians and physicians and for radiology/MRI technologists to support safe MR scanning. It defines pre-MRI assessment requirements, including confirmation of an MR Conditional system and screening for adverse conditions. It instructs clinicians to review potential adverse events, generate a report of permanently programmed parameters outside the scanner room, and select and save MRI settings such as MRI Mode, MRI Base Rate, and MRI Paced AV Delay.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/aveir-dr-dual-chamber-leadless-pacemaker-system-mri-guide-step-by-step-instructions-for-assessment-and-programming/646474/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/aveir-dr-dual-chamber-leadless-pacemaker-system-mri-guide-step-by-step-instructions-for-assessment-and-programming/646474.png","ImageObject",300,407,{"name":92,"@type":93},"Sarah ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-05","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How should clinicians confirm the patient has an MR Conditional system before MRI scanning?","Question",{"text":112,"@type":113},"Review the patient’s ID card or generate a report with the Merlin PCS Programmer to obtain device model numbers, then verify each model number is MR Conditional (e.g., LSP112V, LSP202V, LSP201A, LSP203A).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What adverse conditions mean the patient should not be scanned?",{"text":117,"@type":113},"Examples include devices at end-of-service, implanted leadless pacemakers positioned outside the specified chamber sites, unstable capture thresholds or thresholds greater than 2.5V@0.5ms, diaphragmatic stimulation concerns under specified outputs when pacing will be enabled, or other non-MR Conditional implants such as abandoned leads.",{"name":119,"@type":110,"acceptedAnswer":120},"What are the main MRI settings that can be selected and saved?",{"text":121,"@type":113},"Under Parameters > MRI Settings, clinicians can change MRI Mode, MRI Base Rate, and MRI Paced AV Delay (with provided nominal values and options for each).","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646474,1793105916,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":4},962085320529,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","AVEIR ™ DR DUAL CHAMBER  \nLEADLESS PACEMAKER SYSTEM  \nMRI GUIDE  \nGUIDE FOR CARDIAC CLINICIANS AND PHYSICIANS GUIDE FOR RADIOLOGISTS AND MRI TECHNOLOGISTS  \nTABLE OF CONTENTS  \nPage 3 | For Cardiac Physicians or Clinicians   \nPage 20 | For Radiologists or MRI Technologists   \nPage 27 | Additional Resources   \nAVEIR ™ DR DUAL CHAMBER LEAD LESS PACEMAKER SYSTEM MRI GUIDE  \nROLES OF THE CARDIAC PHYSICIANS AND CLINICIANS  \nSTEP-BY-STEP INSTRUCTIONS  \nFOR ASSESSMENT AND PROGRAMMING  \nPRE-MRI SCAN STEPS  \nStep 1: Confirm that the Patient has an MR Conditional System  \nStep 2: Confirm that No Adverse Conditions to MRI Scanning are Present  \nStep 3: Review the Potential Adverse Events  \nStep 4: Generate a Report of the Patient’s Permanently Programmed Parameters  \nStep 5: Select and Save MRI Settings  \nStep 6: Review the MRI Checklist and Program MRI Settings  \nPOST-MRI SCAN STEPS  \nStep 7: Disable MRI Settings  \nREMINDER: It is required to program the AVEIR ™ DR LP System to MRI Settings as part of the MRI scan workflow.  \nPROCEED TO STEP 1 >  \nAVEIR ™ DR DUAL CHAMBER LEAD LESS PACEMAKER SYSTEM MRI GUIDE  \nROLES OF THE CARDIAC PHYSICIANS AND CLINICIANS  \nSTEP 1  \nCONFIRM THAT THE PATIENT  \nHAS AN MR CONDITIONAL SYSTEM  \nReview the patient’s ID card or a printed report generated by the Merlin™ Patient Care System (PCS) Programmer to obtain the model number for the implanted device(s) . Check that each model number is MR Conditional.  \n| MR Conditional Models for the AVEIR™ Leadless Pacemaker System |\n| --- |\n| LSP112V |\n| LSP202V |\n| LSP201A |\n| LSP203A |\n\nAVEIR ™ Single Chamber Leadless Pacemakers and Dual Chamber Leadless Pacemaker System are MR Conditional  \nPatient ID card with model number highlighted.  \nIF CONFIRMED, PROCEED TO STEP 2 >  \nAVEIR ™ DR DUAL CHAMBER LEAD LESS PACEMAKER SYSTEM MRI GUIDE  \nROLES OF THE CARDIAC PHYSICIANS AND CLINICIANS  \nSTEP 2  \nCONFIRM THAT NO ADVERSE CONDITIONS TO MRI SCANNING ARE PRESENT  \nEXAMPLES OF ADVERSE CONDITIONS:  \n• A device is at End-of-Service  \n• An implanted LSP112V or LSP202V is implanted at a site other than the right ventricle  \n• An implanted LSP201A or LSP203A is implanted at a site other than the right atrium  \n• A device has unstable capture thresholds OR has a threshold greater than 2.5V@0.5ms  \n• Complaints of diaphragmatic stimulation when outputs are set to 5.0V@1.0ms, if the patient will be paced when MRI Settings are enabled  \n• Patients with other non-MR Conditional implants (eg. abandoned leads)  \nSEE NEXT PAGE FOR FURTHER CLARIFICATION RELATED TO ADDITIONAL IMPLANTED DEVICES OR ABANDONED LEADLESS PACEMAKERS.  \nAVEIR ™ DR DUAL CHAMBER LEAD LESS PACEMAKER SYSTEM MRI GUIDE  \nROLES OF THE CARDIAC PHYSICIANS AND CLINICIANS  \nADDITIONAL NOTES FOR CLARIFICATION  \nIT IS ACCEPTABLE TO SCAN PATIENTS WITH OTHER MR CONDITIONAL  \nIMPLANTABLE DEVICES PROVIDED ALL MR CONDITIONAL REQUIREMENTS  \nFOR EACH IMPLANTED DEVICE ARE MET.  \nIT IS ACCEPTABLE TO SCAN PATIENTS WITH OTHER ABANDONED MR CONDITIONAL LEADLESS PACEMAKERS IN THE SAME CHAMBER, AS LONG AS:  \n1. MR conditions for each leadless pacemaker are met  \n2. Abandoned leadless pacemakers are deactivated  \nIF ANY CONDITIONS EXIST WHICH  \nCOULD MAKE MRI SCANNING UNSAFE, IF NO ADVERSE CONDITIONS PRESENT, PROCEED TO STEP 3 >  \nDO NOT SCAN THE PATIENT.  \nAVEIR ™ DR DUAL CHAMBER LEAD LESS PACEMAKER SYSTEM MRI GUIDE  \nROLES OF THE CARDIAC PHYSICIANS AND CLINICIANS  \nSTEP 3  \nREVIEW THE POTENTIAL ADVERSE EVENTS  \nTHE AVEIR™ DR DUAL CHAMBER LEADLESS PACEMAKER SYSTEM HAS BEEN DESIGNED TO MINIMIZE POTENTIAL ADVERSE EVENTS THAT MAY  \nCAUSE PATIENT HARM.  \nPlease refer to the MRI-Ready Leadless Systems Manual for a complete list of potential adverse events that may occur in the MRI environment here.  \nONCE POTENTIAL ADVERSE EVENTS ARE REVIEWED, PROCEED TO STEP 4 >  \nAVEIR ™ DR DUAL CHAMBER LEAD LESS PACEMAKER SYSTEM MRI GUIDE  \nROLES OF THE CARDIAC PHYSICIANS AND CLINICIANS  \nSTEP 4  \nGENERATE A REPORT OF THE PATIENT’S  \nPERMANENTLY PROGRAMMED P","cbCain62lmi16ncu","https://ap.wps.com/l/cbCain62lmi16ncu","pdf",25044209,28,"English","# For Cardiac Physicians or Clinicians\n## Step-by-step instructions for assessment and programming\n## Pre-MRI scan steps\n### Step 1-6\n## Post-MRI scan steps\n### Step 7\n# For Radiologists or MRI Technologists\n## Additional resources","[{\"question\":\"How should clinicians confirm the patient has an MR Conditional system before MRI scanning?\",\"answer\":\"Review the patient’s ID card or generate a report with the Merlin PCS Programmer to obtain device model numbers, then verify each model number is MR Conditional (e.g., LSP112V, LSP202V, LSP201A, LSP203A).\"},{\"question\":\"What adverse conditions mean the patient should not be scanned?\",\"answer\":\"Examples include devices at end-of-service, implanted leadless pacemakers positioned outside the specified chamber sites, unstable capture thresholds or thresholds greater than 2.5V@0.5ms, diaphragmatic stimulation concerns under specified outputs when pacing will be enabled, or other non-MR Conditional implants such as abandoned leads.\"},{\"question\":\"What are the main MRI settings that can be selected and saved?\",\"answer\":\"Under Parameters \\u003e MRI Settings, clinicians can change MRI Mode, MRI Base Rate, and MRI Paced AV Delay (with provided nominal values and options for each).\"}]","AVEIR DR Dual Chamber Leadless Pacemaker System MRI Guide - Step-by-Step Instructions for Assessment and Programming | PDF",1792762198,71]