[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-676775-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-676775-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","automatic-gate-lock-installation-manual","Automatic Gate Lock - Installation Manual","","Installation manual for the GTO Automatic Gate Lock (FM143) designed for Mighty Mule automatic gate openers. Provides pre-installation requirements for proper gate closure and lock catch engagement, guidance for adjustments with Mighty Mule E-Z Gate and GTO/PRO openers, and positioning rules for push-to-open gates. Details required components, mounting hardware selection for iron/aluminum tube and chain link gates, and step-by-step procedures for single and dual gate installations.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/automatic-gate-lock-installation-manual/676775/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/automatic-gate-lock-installation-manual/676775.png","ImageObject",300,407,{"name":42,"@type":43},"Oliver","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":51,"interactionType":52,"userInteractionCount":4},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What must be true about the gate before installing the automatic gate lock?","Question",{"text":61,"@type":62},"The gate must close firmly and engage the lock catch against the lock receiver. The gate should move freely on its hinges and not bind or drag against the ground.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"Is mounting hardware included with the gate lock?",{"text":66,"@type":62},"No. No mounting hardware is provided with the GTO Automatic Gate Lock; all necessary mounting hardware must be obtained locally.",{"name":68,"@type":59,"acceptedAnswer":69},"How do installation steps differ for single vs dual gate systems?",{"text":70,"@type":62},"The manual provides separate procedures: single gate installation covers locating, clamping, drilling, and securing the lock and receiver, while dual gate installation includes defining the master and slave gate openers based on the control box side.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},676775,1793776676,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,103,108,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":101,"slug":102},6,50,"technology",{"id":104,"doc_module":4,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},7,"Healthcare",40,"healthcare",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},8,"Research & Report",30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":100,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":4,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":138,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":78,"read_time":143},8796095461610,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","User Manual of Product 1:  \nAutomatic Gate Lock (FM143) for Mighty Mule Automatic Gate Openers , Black  \nUser Manual of Product 2:  \n10 Watt Solar Panel Kit (FM123) for Mighty Mule Automatic Gate Openers,Black Cell  \nIMPORTANT: Before you install the automatic gate lock be sure your gate is level, moves freely on its hinges, and does not bind or drag against the ground.  \nAUTOMATIC GATE LOCK  \n®  \nInstallation Manual  \nPLEASE NOTE: Because of the various mounting applications, no mounting hardware is provided with the GTO Automatic Gate Lock. All necessary mounting hardware can be obtained from your local hardware store; all other hardware is provided.  \nThis manual shows two examples of the most common installations, and should provide insight into most other applications. If you have any questions during installation, please call (850)  \n575-4144 for technical support.  \nRB909 rev-6/23/05 © GTO, Inc. 2000  \nBefore You Start...  \nFor the GTO Automatic Gate Lock to work properly, the gate must close ﬁrmly and engage the lock catch against the lock receiver. Achieving optimal closure may require slight adjustments to the gate opener settings. Installing the lock with the Mighty Mule® E-Z Gate® Opener may require slight movement of the stroke adjustment and changes to the obstruction sensitivity. See Setting the Gate Closed Position in your Mighty Mule Installation Manual for information on these adjustments.  \nInstalling the lock with a GTO/PRO gate opener may require slight movement of the stroke adjustment and changes to the obstruction sensitivity (see your GTO/PRO Installation Manual for information on these adjustments) .  \nIf you are installing the lock on a Push-to-Open gate (gate opens out), the lock must be installed on the outside of the gate. Depending upon the installation, the gate post may need to be \"pocketed\" to accommodate the lock receiver. Contact the GTO Technical Service Department at (850) 575-4144 for assistance.  \nBe sure you have all  \nA-Lock with 20' of low voltage wire B-Lock Receiver  \nC-Clevis Pin  \nD-Locking Cap  \nE-Lock Board Battery Lead Wires F-White Wire (motor lead to lock board) G-Lock Control Board  \nH-2 Double Spade Tongue terminals I- 6 nylon cable ties  \nJ- Wire Connector  \nK-Lock Keys (for manual release) L-Lock Decal  \nthe  \nL  \n| | AUTOMATIC GATE LOCK\u003Cbr>® |\n| --- | --- |\n|  |  |\n\nH  \nWhat else do you need?  \nMounting hardware is not included. Read these instructions completely and review the installation examples to determine the mounting hardware required for your application.  \nNOTE: The GTO Lock is designed to use mounting hardware up to5/16\" in diameter. For a more secure installation, use lock washers and lock nuts on all mounting hardware.  \nFor most IRON or ALUMINUM TUBE gates you will need:  \nCarriage bolts, washers, and nuts for the lock and receiver. (see Illustration B, page 3)  \nFor most CHAIN LINK gates you will need:  \nU-Bolts, saddles or carriage bolts, washers and nuts for the lock.  \nBolts, washers, and nuts for the receiver. (see Illustration C, page 3)  \nThe installation has two parts:  \n(1) Mounting The Lock and Lock Receiver  \n(2) Connecting the Control Boards  \nOnce you have the necessary mounting hardware, you can begin the installation.  \nInstalling The Gate Lock  \nNOTE: The Automatic Gate Lock can be installed on single and dual gate systems. Use the appropiate instructions for the system you have-SINGLE GATE (below) or DUAL GATES (page 4) .  \nSingle Gate Installation  \nDisconnect gate opener by removing hairpin clip and clevis pin from the gate bracket end of the opener. Disconnecting the opener will allow the gate to swing freely during installation of the gate lock.  \nStep 1: With the gate in the closed position, determine the best location for the lock and lock receiver. The lock and receiver must be level and aligned with the opener. Also, the lock should have a solid surface or cross member to provide stability.  \nStep 2 : Clamp receiver and lock togethe","cbCaiibo5tFwzPNt","https://ap.wps.com/l/cbCaiibo5tFwzPNt","pdf",2300442,18,"English","# Before You Start...\n# What else do you need?\n# Installing The Gate Lock\n## Single Gate Installation\n## Dual Gate Installation","[{\"question\":\"What must be true about the gate before installing the automatic gate lock?\",\"answer\":\"The gate must close firmly and engage the lock catch against the lock receiver. The gate should move freely on its hinges and not bind or drag against the ground.\"},{\"question\":\"Is mounting hardware included with the gate lock?\",\"answer\":\"No. No mounting hardware is provided with the GTO Automatic Gate Lock; all necessary mounting hardware must be obtained locally.\"},{\"question\":\"How do installation steps differ for single vs dual gate systems?\",\"answer\":\"The manual provides separate procedures: single gate installation covers locating, clamping, drilling, and securing the lock and receiver, while dual gate installation includes defining the master and slave gate openers based on the control box side.\"}]","Automatic Gate Lock - Installation Manual | PDF",45]