[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-459298-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-459298-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","automated-segmentation-of-thoracic-aortic-lumen-and-vessel-wall-on-three-dimensional-bright-and-black-blood-magnetic-resonance-imaging-using-nnu-net-original-research","Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net - Original Research","","Magnetic resonance angiography (MRA) supports thoracic aortic assessment, yet manual segmentation is time-consuming and affected by operator variability. Two deep-learning models were developed and validated for automated segmentation of the aortic lumen and vessel wall in high-resolution, three-dimensional bright- and black-blood MRA after respiratory motion correction. Models were trained using nnU-Net variants with manual annotations as ground truth and evaluated with Dice similarity coefficient and Intersection over Union across multi-center datasets.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/automated-segmentation-of-thoracic-aortic-lumen-and-vessel-wall-on-three-dimensional-bright-and-black-blood-magnetic-resonance-imaging-using-nnu-net-original-research/459298/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/automated-segmentation-of-thoracic-aortic-lumen-and-vessel-wall-on-three-dimensional-bright-and-black-blood-magnetic-resonance-imaging-using-nnu-net-original-research/459298.png","ImageObject",300,407,{"name":42,"@type":43},"Hazel","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-31","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the document’s main objective?","Question",{"text":63,"@type":64},"To optimize and validate two deep-learning models for automatic segmentation of the thoracic aortic lumen and vessel wall in 3D bright- and black-blood MRA images.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How is ground truth generated for training?",{"text":68,"@type":64},"Manual segmentation is used as ground truth on 25 bright-blood and 15 black-blood 3D MRA image sets from thoracic aortopathy patients.",{"name":70,"@type":61,"acceptedAnswer":71},"Which metrics and postprocessing steps are used to evaluate performance?",{"text":72,"@type":64},"Performance is assessed using Dice similarity coefficient (DSC) and Intersection over Union (IoU), with postprocessing including centerline extraction, diameter measurement, and curved planar reformatting (CPR).","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},459298,1790794814,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":33,"preview_urls":146},137441390410,"https://ap-avatar.wpscdn.com/avatar/2000252f4ab5702993?_k=1776741390130283984","Journal of Cardiovascular Magnetic Resonance 27 (2025) 101923  \nContents lists available at ScienceDirect  \nJournal of Cardiovascular Magnetic Resonance  \njournal [homepage:](homepage: www.sciencedirect.com/journal/joc mr)[ www.sciencedirect.com/journal/joc mr](homepage: www.sciencedirect.com/journal/joc mr)  \nOriginal Research  \nAutomated segmentation of thoracic aortic lumen and vessel wall on threedimensional bright- and black-blood magnetic resonance imaging using nnU-Net  \nMatteo Cesarioa,b,c,1, Simon J. Littlewooda, James Nadela,d,e, Thomas J. Fletchera, Anastasia Fotakia, Carlos Castillo-Passia,f, Reza Hajhosseinya,g, Jim Pouliopoulose,h, Andrew Jabboure,h, Ruperto Oliveroi,j,k,l, Jose Rodríguez-Palomaresi,j,k,l, M. Eline Kooib,c, Claudia Prietoa,m,n, René M. Botnara,f,m,n,o,⁎  \na School of Biomedical Engineering and Imaging Sciences, King’s College London, London, United Kingdom b Department of Radiology and Nuclear Medicine, Maastricht University Medical Centre, Maastricht, the Netherlands c Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, the Netherlands d Clinical Research Group, Heart Research Institute, Newtown, Australia  \ne Cardiology Department, St. Vincent’s Hospital, Darlinghurst, Australia  \nf Institute of Biological and Medical Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile g Department of Cardiology, Chelsea and Westminster Hospital NHS Foundation Trust, London, United Kingdom h Victor Chang Cardiac Research Institute, Sydney, Australia  \ni Department of Cardiology, Vall d′Hebron Hospital Universitari, Vall d′Hebron Barcelona Hospital Campus, Barcelona, Spain j Department of Medicine, Universitat Autònoma de Barcelona, Bellaterra, Spain  \nk Cardiovascular Diseases, Vall d′Hebron Institut de Recerca (VHIR), Vall d′Hebron Barcelona Hospital Campus, Universitat Autònoma de Barcelona, Bellaterra, Spain  \nl CIBER de Enfermedades Cardiovasculares, Instituto de Salud Carlos III, Madrid, Spain m School of Engineering, Pontificia Universidad Católica de Chile, Santiago, Chile n Millennium Institute for Intelligent Healthcare Engineering, Santiago, Chile  \no Institute for Advanced Study, Technical University of Munich, Garching, Germany  \nA R T I C L E I N F O  \nKeywords:  \nAorta  \nAortic disease  \nMagnetic resonance angiography Segmentation  \nDeep-learning  \nnnUNet  \nA B S T R A C T  \nBackground: Magnetic resonance angiography (MRA) is an important tool for aortic assessment in several cardiovascular diseases. Assessment of MRA images relies on manual segmentation, a time-intensive process that is subject to operator variability. We aimed to optimize and validate two deep-learning models for automatic segmentation of the aortic lumen and vessel wall in high-resolution electrocardiogram-triggered free-breathing respiratory motion-corrected three-dimensional (3D) bright- and black-blood MRA images.  \nMethods: Manual segmentation, serving as the ground truth, was performed on 25 bright-blood and 15 blackblood 3D MRA image sets acquired with the iT2PrepIR-BOOST sequence (1.5T) in thoracic aortopathy patients. The training was performed with no new U-Net (nnUNet) for bright-blood (lumen) and black-blood image sets (lumen and vessel wall). Training consisted of a 70:20:10% (17/25:5/25:3/25 datasets) training:validation:testing split. Inference was run on datasets (single vendor) from different centers (UK, Spain, and Australia), sequences (iT2PrepIR-BOOST, T2 prepared coronary magnetic resonance angiography [CMRA], and time-  \nAbbreviation: 2D/3D/4D, two/three/four-dimensional; AA, aortic aneurysm(s); BLnnUNet, black-blood nnUNet model trained to segment aortic lumen and wall; BRnnUNet, bright-blood nnUNet model trained to segment aortic lumen; CE, contrast enhanced; CMRA, coronary magnetic resonance angiography; CPR, curved planar reformat; CSA, cross-sectional area; CTA, computed tomography angiography; DL, deep learning; GT, ground truth; GUI, guided user","cbCailcvNCBaUTb7","https://ap.wps.com/l/cbCailcvNCBaUTb7","pdf",9155954,14,"English","# Original Research\n## Automated segmentation approach\n## Methods and dataset design\n## Inference and evaluation metrics\n## Postprocessing\n## Results","[{\"question\":\"What is the document’s main objective?\",\"answer\":\"To optimize and validate two deep-learning models for automatic segmentation of the thoracic aortic lumen and vessel wall in 3D bright- and black-blood MRA images.\"},{\"question\":\"How is ground truth generated for training?\",\"answer\":\"Manual segmentation is used as ground truth on 25 bright-blood and 15 black-blood 3D MRA image sets from thoracic aortopathy patients.\"},{\"question\":\"Which metrics and postprocessing steps are used to evaluate performance?\",\"answer\":\"Performance is assessed using Dice similarity coefficient (DSC) and Intersection over Union (IoU), with postprocessing including centerline extraction, diameter measurement, and curved planar reformatting (CPR).\"}]","Automated segmentation of thoracic aortic lumen and vessel wall on three-dimensional bright- and black-blood magnetic resonance imaging using nnU-Net - Original Research | PDF",1790755624,35,[147,151,155,159],{"page_no":22,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1f5b9265d76312ea70c8457c7a33ee2f.webp",983,1310,{"page_no":26,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0577bf45841375a001b59b5a34700361.webp",982,1309,{"page_no":30,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/31da727146a339c86501eeb37271aa85.webp",981,1308,{"page_no":33,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/9875dbde707001db3b9450eb67b8136e.webp",980,1306]