[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-653116-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-653116-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","atpaspasup-price-computing-scales-operation-manual-rev-c1-calibration-operation-guide","ATP/ASP/ASUP Price computing scales operation manual - REV: C1 - Calibration & Operation Guide","","Operation manual for ATP/ASP/ASUP price computing scales, covering calibration and day-to-day functions. Explains password-protected parameter entry during self-check, how to access the F0 CAL calibration menu, and how to zero, tare, perform overload checks, and set units and unit price. Details accumulator and account workflows, including saving/loading unit prices, using direct PLU (ASUP), and other features such as backlight modes, automatic unit-price clearing, auto power-off sleep settings, and audit viewing.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/atpaspasup-price-computing-scales-operation-manual-rev-c1-calibration-operation-guide/653116/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/atpaspasup-price-computing-scales-operation-manual-rev-c1-calibration-operation-guide/653116.png","ImageObject",300,407,{"name":42,"@type":43},"Danger Angel","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-31","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":26},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"How do you enter the parameter menu and start calibration for F0 CAL?","Question",{"text":62,"@type":63},"During self-checking, press the TARE key to enter the parameter menus; the default password is 0000. When the menu shows “F0 CAL”, press the TARE key to proceed.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What are the steps for zeroing and tare before normal weighing?",{"text":67,"@type":63},"After stable indication, press the TARE key to set the zero point. For tare operation, press the TARE key to subtract tare values and switch from gross mode (no tare) to net mode.",{"name":69,"@type":60,"acceptedAnswer":70},"How is unit price memory saved and recalled?",{"text":71,"@type":63},"Hold the PLU key for 3 seconds after keying the unit price to show “save pos”, then choose a memory location 0~9 to store. To load, press the PLU key to show “load pos”, then select 0~9 to switch the current unit price to the stored value.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},653116,1792885711,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":26,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":101,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":79,"read_time":143},962090769052,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","ATP/ASP/ASUP Price Computing Scales  \nATP/ASP/ASUP Price computing scales operation manual REV: C1, June 2012 ATP/ASP/ASUP Price computing scales operation manual   \n8. CALIBRATION Contents  \nPress TARE key during self-checking to enter the parameter menus, the default password is 0000.  \nWhen the parameter menu show \"F0 CAL\" press the TARE key. 1 INTRODUCTION……………………………..……….…….…….…...…1  \nThe display will then show \"unLoAd\" to request all weight be removed 2 KEYBOARD DESCRIPTIONS…………………….…….….………….1  \nfrom the platform. 3 GENERAL INSTRUCTION………………………………..……………2  \nPress the TARE key to set the zero point after the stable indication 4 BASIC OPERATION…………………………….…..………..…………2  \non. 4.1 Zeroing the scale………………..………….…………….………2  \nKey in the calibration weight you want to use then put this weight on 4.2 Tare…………………………………………………………………2  \nthe platform and then press the TARE key. The scale should be stable 4.3 Overload warning…………………..………………….…….……3  \nafter pressing the TARE key to accept a weight. The stability indicator 4.4 unit price setting…………………….………………….……….…3  \nwill turn on to show the value is stable. 4.5 Change unit…………………………………………….………..…3  \nWhen calibration is finished the scale will come into natural weighing 5. ACCUMULATOR OPERATION…………….…………………………..3  \nif it was successful. 5.1 prepare to Accumulator………………..……………….…………3  \n5.2 Accumulator operation………………….……………….…….….3  \n5.3 Account operation………………………………………….………4  \n6. UNIT PRICE MEMORY………………….………………………….……..4  \n6.1 Save the Unit price…………………..……………….….………4  \n6.2 Load the Unit price…………………….……………….…..……..4  \n6.3 Use direct PLU……………………………………………..………4  \n7. OTHER FUNCTION…………………………….……………….…………5  \n7.1 backlight………………………………………..……….….………5  \n7.2 Automatic unit price clear…………………………………………5  \n7.3 Auto power off……………………………………….….……….…5  \n7.4 View audit operate…………………………………………………5  \n8. CALIBRATION……………………………………………………………6  \n7. OTHER FUNCTION  \n7.1 Backlight  \nScale have three backlight mode: on, off and auto.  \nOFF: backlight will turn off however current weight is any weight. AUTO: backlight will turn on when current weight is not zero and it will turn off if current weight is zero  \nYou can press B/L key to set backlight mode, press B/L key to shift in AUTO and OFF mode.  \n7.2 Automatic unit price clear  \nscale can set automatic unit price clear, when return to zero, scale will clear the unit price automatically.  \nPress SAVE key will turn on / off automatic unit price clear function, when SAVE indicator on, automatic unit price clear disable, when SAVE indicator off, automatic unit price clear enable.  \n7. 3 Auto power off  \nscale have auto shut off function, you can set this parameter.  \nPress ACCOUNT key during self-checking, display shows “sleep mode”, press SAVE key to select 0/1/5/30 (not use auto power off / turn off power after scale leisure for 1 minutes / turn off power after scale leisure for 5 minutes / turn off power after scale leisure for 30 minutes), press TARE key to sure  \n7. 4 View audit operate  \nPress SAVE key during self-checking, display shows AUDIT OPT AA CAL BB, press ZERO key to escape. AA is parameter setting times, BB is calibrate times.  \n5. 3 Account operation  \nAfter do accumulate operate, you can press ACCOUNT key, WEIGHT window will show the summed price, key in paid money by keyboard, this will show on Unit Price window, and the Total Price window will show the return value.  \nPress TARE key to return normal weighing mode and clear memory, if you don’t want clear memory, press ZERO key to return normal weighing mode.  \nNote: if you haven’t do accumulate operation, you also can use Account function, the summed price is current total price.  \n6. UNIT PRICE MEMORY  \nscale can store 10 sets unit price.  \n6. 1 Save the unit price  \nHold the PLU key for 3 seconds after you key in the unit price, it will show “save pos” , press numeric key 0~9 to select which memory location you want to use. After you do, the unit price is stored in the scale.  \n6.2 Lo","cbCaidsPrYIrrs2n","https://ap.wps.com/l/cbCaidsPrYIrrs2n","pdf",114296,"English","# Introduction\n# Key descriptions\n# General instruction\n# Basic operation\n## Zeroing the scale\n## Tare\n## Overload warning\n## Unit price setting\n## Change unit\n# Accumulator operation\n## Prepare to Accumulator\n## Accumulator operation\n## Account operation\n# Unit price memory\n## Save the unit price\n## Load the unit price\n## Use direct PLU","[{\"question\":\"How do you enter the parameter menu and start calibration for F0 CAL?\",\"answer\":\"During self-checking, press the TARE key to enter the parameter menus; the default password is 0000. When the menu shows “F0 CAL”, press the TARE key to proceed.\"},{\"question\":\"What are the steps for zeroing and tare before normal weighing?\",\"answer\":\"After stable indication, press the TARE key to set the zero point. For tare operation, press the TARE key to subtract tare values and switch from gross mode (no tare) to net mode.\"},{\"question\":\"How is unit price memory saved and recalled?\",\"answer\":\"Hold the PLU key for 3 seconds after keying the unit price to show “save pos”, then choose a memory location 0~9 to store. To load, press the PLU key to show “load pos”, then select 0~9 to switch the current unit price to the stored value.\"}]","ATP/ASP/ASUP Price computing scales operation manual - REV: C1 - Calibration & Operation Guide | PDF",15]