[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-665206-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-665206-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","ati-0922-system-diagram-system-diagram-w-optional-ph-sensor","ATI-0922 System Diagram - System Diagram w/ Optional pH Sensor","","Technical support drawings covering system diagrams and component installation details for ATI-0922 to ATI-0929, including system layouts with optional pH sensor, sealed flowcell configurations, and mounting assemblies. Specifies analyzer dimensions for wall mount use, housing and junction box elements, pipe and panel mounting, and flow sensor dimensions with overflow cell installation steps. Includes materials and ratings such as polycarbonate with Nema 4X (IP-66) and V-0 fire retardant, plus sensor fitting types, connector and sensor characteristics, and guidance for electrical connections and relay wiring.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/ati-0922-system-diagram-system-diagram-w-optional-ph-sensor/665206/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/ati-0922-system-diagram-system-diagram-w-optional-ph-sensor/665206.png","ImageObject",300,407,{"name":42,"@type":43},"sagouaw","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":30},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"What components are covered in the ATI system diagrams and support drawings?","Question",{"text":62,"@type":63},"The document lists system diagrams (with optional pH sensor and sealed flowcell), mounting plate assemblies, junction box, and multiple sensor and flowcell installation-related drawings.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What are the key material and rating details mentioned for the analyzer enclosure?",{"text":67,"@type":63},"Material is stated as polycarbonate, with ratings including Nema 4X (IP-66) and V-0 fire retardant.",{"name":69,"@type":60,"acceptedAnswer":70},"How do the electrical connection instructions change when a pH sensor is installed?",{"text":71,"@type":63},"The drawing specifies removing jumpers 3-5 and 6-9 when the pH sensor is installed.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},665206,1793293213,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":30,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":112},3985747862151,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","STANDARD SYSTEM DIAGRAM  \nATI-0922  \nSYSTEM DIAGRAM w/ OPTIONAL pH SENSOR  \nATI-0923  \nSYSTEM DIAGRAM w/SEALED FLOWCELL  \nATI-0924  \nSYSTEM MOUNTING PLATE ASSY  \nMounting Plate w/o Flowswitch –(03-0374)  \nMounting Plate w/Flowswitch –(03-0344) currently shown  \nATI-1224  \nANALYZER DIMENSIONS (WALL MOUNT SHOWN)  \nMaterial: Polycarbonate  \nRatings: Nema 4X (IP-66) V-0 Fire Retardant  \nATI-0926  \nJUNCTION BOX  \nATI-0655  \nPIPE MOUNTING  \nATI-0927  \nPANEL MOUNTING  \nATI-0928  \nFLOW SENSOR DIMENSIONS & OVERFLOW CELL INSTALLATION  \n1.  \n2.  \n3.  \nOverflow Cell Assembly  \n(4) ¼” DIA. HOLES CUSTOMER MOUNTING  \n(00-0043)  \nATI-0196  \n178mm  \nFITTING (DRAIN)  \nBARB FITTING (INLET)  \n2.75”  \n114mm  \n1/16” THK S.S.  \nCLEAR ACRYLIC  \nD.O3 FLOW SENSOR (00-0042)  \n4.20”  \n107mm  \nCONNECTOR  \nSensor Material:  \nBlack PVC and Stainless Steel  \nConnector is not submersible  \nOuter Dia of Sensor: 1.75”  \n44.5mm  \nCl2 SEALED FLOWCELL ASSY  \n(00-1522)  \nMaterial: Acrylic  \nMounting Plate: PVC  \nMaterial: Acrylic  \nMounting Plate: PVC  \npH SEALED FLOWCELL ASSY  \n(00-1527)  \n(07-0096) pH SENSOR DIMENSIONS  \n(63-101) pH SENSOR DIMENSIONS  \nSPECIAL APPLICATION FLOWCELLS (CONSULT FACTORY)  \n1. Sensor Material:  \nBlack PVC & Stainless Steel  \n2. Connector is not submersible  \n3. Outer Diameter of Sensor:  \n1.75” Dia.  \n44.5mm  \nConnector    \n1 ¼” NPT   \nD.O3 Flow Sensor (00-0042)   \nFlow “T”  \n1. Max 50 PSI for Flow “T”  \nOperation  \n2. Use Teflon Tape to seal In-Line Sensor  \nLow Volume Flowcell  \n1. Matl: Clear Acrylic  \nLow Volume Flowcell Assy  \n(00-0633)  \n(2) ¼” Barb Fittings ~~ ~~  \n(2) \\#8-32 Threaded Inserts  1.0”  \n25.4mm  \n2.0”  \n1 ¼”  \nPVC Flow Adapter  \nSCH 80 1 ½ PVC Flow “T”  \nAssembly (00-0625)  \n50.8mm  \nATI-0197  \n4.813” 122mm  \n3.325” 84.5mm  \nSUBMERSIBLE SENSOR DIMENSIONS  \n25’ Cable Standard   \nD.O3 Submersible Sensor (00-0065)  \n1” NPT ~~ ~~  \nTemperature ~~  ~~Sensor  \nATI-004  \n| |\n| --- |\n|  |\n\n145mm 4.9”  \nSUBMERSIBLE SENSOR INSTALLATION  \nPOWER, RELAY, AND OUTPUT CONNECTIONS  \nATI-0930, 0932, 0933, 0989  \nRELAY WIRING TB4,5,6 DETAIL  \nATI-0931  \nELECTRICAL CONNECTIONS  \nRemove jumpers 3-5 & 6-9 if pH sensor is installed  \nATI-0929","cbCaiaftW0g447N2","https://ap.wps.com/l/cbCaiaftW0g447N2","pdf",1595041,12,"English","# System Diagram Sets\n## System Diagram with Optional pH Sensor\n## System Diagram with Sealed Flowcell\n## Analyzer Dimensions and Mounting Parts\n# Flow Sensors and Flowcell Assemblies\n## Flow Sensor Dimensions and Overflow Cell Installation\n## Special Application Flowcells\n## Low Volume Flowcell\n## Submersible Sensor Dimensions and Installation\n# Electrical Connections\n## Power, Relay, and Output Connections\n## Relay Wiring TB4-6 Detail\n## Electrical Connection Jumper Guidance","[{\"question\":\"What components are covered in the ATI system diagrams and support drawings?\",\"answer\":\"The document lists system diagrams (with optional pH sensor and sealed flowcell), mounting plate assemblies, junction box, and multiple sensor and flowcell installation-related drawings.\"},{\"question\":\"What are the key material and rating details mentioned for the analyzer enclosure?\",\"answer\":\"Material is stated as polycarbonate, with ratings including Nema 4X (IP-66) and V-0 fire retardant.\"},{\"question\":\"How do the electrical connection instructions change when a pH sensor is installed?\",\"answer\":\"The drawing specifies removing jumpers 3-5 and 6-9 when the pH sensor is installed.\"}]","ATI-0922 System Diagram - System Diagram w/ Optional pH Sensor | PDF"]