[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-468787-105":59,"doc-detail-468787-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","asynchronous-stepped-fourier-transform-ion-mobility-spectrometry-research-overview","Asynchronous Stepped Fourier Transform Ion Mobility Spectrometry - Research overview","","Fourier Transform Ion Mobility Spectrometry (FTIMS) uses a frequency sweep to convert pulsed gate measurements into a mobility spectrum via Fast Fourier Transform processing, improving duty cycle, resolving power, and signal-to-noise ratio. Low-cost function-generator inconsistencies can create spectral artifacts, so this work demonstrates an asynchronous stepped-frequency FTIMS approach using a simple software timed pulse generator compatible with modern ADC systems. Parameters are optimized for resolution, SNR, and experimental time. After optimization, significant performance gains are achieved without increasing experimental duration, and a Python-based acquisition workflow is validated across ADC platforms while preserving spectral fidelity. A custom circuit enables Raspberry Pi 4 control for low-cost stand-alone FTIMS.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/asynchronous-stepped-fourier-transform-ion-mobility-spectrometry-research-overview/468787/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/asynchronous-stepped-fourier-transform-ion-mobility-spectrometry-research-overview/468787.png","ImageObject",300,407,{"name":92,"@type":93},"Melati","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What does the asynchronous stepped Fourier transform approach improve in IMS experiments?","Question",{"text":113,"@type":114},"It improves duty cycle, resolving power, and signal-to-noise ratio while converting gate-pulsed data into a time-based mobility spectrum through FFT processing.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"Why can low-cost function generators cause problems in FTIMS?",{"text":118,"@type":114},"Inconsistencies in low-cost function generators introduce spectral artifacts that degrade data quality.",{"name":120,"@type":111,"acceptedAnswer":121},"How is system control and data acquisition handled for low-cost FTIMS?",{"text":122,"@type":114},"A simple, software timed pulse generator and a demonstrated Python script work with commercially available ADC systems, and a custom circuit allows a Raspberry Pi 4 to serve as the data acquisition and control interface.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},468787,1791155130,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962085570644,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","ACS Partner Journal  \nThis article is licensed under CC-BY 4.0   \n[pubs.acs.org/jasms](pubs.acs.org/jasms)  Article   \nAsynchronous Stepped Fourier Transform Ion Mobility Spectrometry  \nEmily Edstrom, Saned Gharari, and Eric Davis*  \n Cite This: J. Am. Soc. Mass Spectrom. 2026, 37, 86−94  \nRead Online  \n\n|  |  |  |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| ACCESS   | Metrics & More |  |  Article Recommendations |  | *sı Supporting Information |\n\nABSTRACT: Fourier Transform is a low-cost method for improving duty cycle, resolving power, and signal-to-noise ratio in the Ion Mobility Spectrometry (IMS) experiment in a 2-gate IMS cell. By simultaneously pulsing both gates through a frequency sweep, the resulting data may be deconvoluted into a time-based mobility spectrum through a Fast Fourier Transform (FT). However, inconsistencies common in low-cost function generators result in spectral artifacts. In this work, an asynchronous stepped frequency FTIMS method is demonstrated, which uses a simple, software timed pulse generator compatible with any modern Analog-Digital Converter (ADC) system. By unlinking the frequency initiation and data collection using a long rise-time amplifier circuit, a standalone FTIMS with Faraday Plate detection was characterized in both single gate and FT modes of operation using the same IMS cell. Asynchronous stepped FTIMS parameters were investigated for system optimization with respect to resolving power, signal-to-noise ratio, and experimental time. Once optimized, asynchronous FTIMS demonstrated significant improvements in resolving power and signal-to-noise ratios without a significant increase in experimental time. By unlinking the frequency generation and data analysis, a simple Python script was demonstrated using a variety of commercially available ADC systems ranging in cost from several thousand to several hundred dollars (USD) without sacrificing spectral fidelity. A custom circuit was developed to allow a Raspberry Pi 4 Single Board Computer (SBC) to function as the data acquisition and control (DAC) interface for a low-cost stand-alone FTIMS solution.  \n■ INTRODUCTION  \nAs a mature technology, Ion Mobility Spectrometry (IMS) is utilized globally in security, military, and scientific applications. 1−5 Its ease of use and ability to separate gas phase ions on the basis of size-to-charge ratios is complementary of Mass Spectral (MS) mass/charge separations and is frequently coupled to MS measurements to provide 2D data. IMS has numerous examples of increasing data available through other analytical methods such as MS,6 GC,7,8 or HPLC.9 The utilization of IMS on a broader scale is limited by the instrumental requirements of this technique, including high frequency pulse generation, amplification of high speed, nAlevel signals, and high-speed analog to digital conversion. Historically, these limitations have been overcome through application of commercially available amplifiers and high-speed Analog to Digital Converter (ADC) modules that come with a  \nsteep price and necessitate significant instrumental and programming experience to implement the IMS experiment. More recently, commercially available, stand-alone, researchgrade IMS units have entered the market, but these are severely limited in resolution and modularity due to their compact size and the nature of commercial instrumentation.10 In an attempt to cover this gap, Reinecke and Clowers developed an open-source IMS platform in 2018 where they described a PCB-based IMS cell and released open source  \n\n| Received: June 30, 2025\u003Cbr>Revised: November 13, 2025\u003Cbr>Accepted: November 20, 2025\u003Cbr>Published: December 8, 2025 | |\n| --- | --- |\n\n© 2025 The Authors. Published by American Chemical Society 86  \n[https://doi.org/10.1021/jasms.5c00220](https://doi.org/10.1021/jasms.5c00220)[ ](https://doi.org/10.1021/jasms.5c00220)J. Am. Soc. Mass Spectrom. 2026, 37, 86−94  \nFigure 1. Experimental diagram for Swept Frequency FTIMS (left, so","cbCairnpWNOn5Tnr","https://ap.wps.com/l/cbCairnpWNOn5Tnr","pdf",4816265,"English","# Abstract\n# Introduction\n## Motivation and limitations of conventional IMS instrumentation\n## Prior open-source IMS platforms and related hardware developments\n## Need for ESI-based measurements with PCB-based instrumentation","[{\"question\":\"What does the asynchronous stepped Fourier transform approach improve in IMS experiments?\",\"answer\":\"It improves duty cycle, resolving power, and signal-to-noise ratio while converting gate-pulsed data into a time-based mobility spectrum through FFT processing.\"},{\"question\":\"Why can low-cost function generators cause problems in FTIMS?\",\"answer\":\"Inconsistencies in low-cost function generators introduce spectral artifacts that degrade data quality.\"},{\"question\":\"How is system control and data acquisition handled for low-cost FTIMS?\",\"answer\":\"A simple, software timed pulse generator and a demonstrated Python script work with commercially available ADC systems, and a custom circuit allows a Raspberry Pi 4 to serve as the data acquisition and control interface.\"}]","Asynchronous Stepped Fourier Transform Ion Mobility Spectrometry - Research overview | PDF",1790774678,23,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/a2d5cb1e81b11b4cd4397c03a7d759c3.webp",983,1296,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f670729b7a50d66d570e68c476b180f4.webp",982,1295,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/3eb05e4e77853be19d09117b86afbf9a.webp",981,1293,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0879e4152767bc65168170b6d0e1daf7.webp",980,1292]