[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-640700-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-640700-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","assert-iq-insertable-cardiac-monitor-i-cm-ai-powered-af-pause-detection","ASSERT-IQ™ INSERTABLE CARDIAC MONITOR (I CM) - AI-POWERED AF & Pause Detection","","AI algorithms in the ASSERT-IQ™ insertable cardiac monitor (ICM) enhance accuracy of atrial fibrillation (AF) and pause episode detection, reducing clinician workload by lowering false positives. The system retains 100% of true AF episodes and 99.2% of true pause episodes, delivering high positive predictive value for episode-based AF performance. It also reduces transmission burden and can save clinic time annually per 100 patients, with AI adjudication in the cloud and updated diagnostics on Merlin.net.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/assert-iq-insertable-cardiac-monitor-i-cm-ai-powered-af-pause-detection/640700/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/assert-iq-insertable-cardiac-monitor-i-cm-ai-powered-af-pause-detection/640700.png","ImageObject",300,407,{"name":42,"@type":43},"Aria","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-10","2026-10-22",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"How does ASSERT-IQ™ improve AF and pause detection accuracy?","Question",{"text":63,"@type":64},"ASSERT-IQ™ ICM uses AI algorithms to enhance the accuracy of AF and pause episode detection, reducing false positives while maintaining high sensitivity. It retains 100% of true AF episodes detected and 99.2% of true pause episodes.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What workflow does the AI algorithm follow in ASSERT-IQ™ ICM?",{"text":68,"@type":64},"The system performs initial detection and transmission of all episodes, then uses AI adjudication in the cloud to remove false episodes. Key episode technology makes true episodes available on Merlin.net, where patient care network diagnostics are updated.",{"name":70,"@type":61,"acceptedAnswer":71},"What impact does ASSERT-IQ™ have on clinician workload and transmissions?",{"text":72,"@type":64},"ASSERT-IQ™ reduces transmission burden and can save clinics substantial annual time per 100 patients. For patients with at least 1 AF or pause alert pre-AI, a 39.4% reduction in transmissions is cited.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},640700,1792710355,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":97,"preview_page_count":4},2336464648322,"https://ap-avatar.wpscdn.com/avatar/2200025388227c56fec?_k=1778556882303663488","ASSERT-IQ™ INSERTABLE CARDIAC MONITOR (I CM)  \nAI POWERS THE  \nASSERT-IQ™ ICM SYSTEM  \nAI ALGORITHMS DELIVER MORE CLINICALLY ACTIONABLE DATA  \nAssert-IQ I CM leverages AI to enhance the accuracy of AF and Pause episode detection, significantly reducing data burden for clinicians.1  \nAI REDUCES FALSE POSITIVES WHILE MAINTAINING HIGH SENSITIVITY  \nPause  \nAF  \nFalse Positives Before AI  \n90.6% false positive reduction in Pause episodes1  \n81.0% false positive reduction in AF episodes1  \nAI retains 100% of true AF episodes detected by Assert-IQ I CMs1,10  \nAI retains 99.2% of true Pause episodes1,10  \nPause  \nAF  \nAI delivers 93.6% Positive Predictive Value (PPV)*1,10  \nFalse Positives After AI  \n*For episode-based AF performance  \nAI ALGORITHM WORKFLOW  \nKey Episodes  \n[Merlin.net](Merlin.net)  \nInitial Detection &  \nTransmission of All Episodes  \nALL AF &  \nPause Episodes  \nAI-Adjudication in the Cloud and Removal of False Episodes  \nApply Key Episode Technology*  \nTrue Episodes Available [on Merlin.net](on Merlin.net) PCN  \nDiagnostics [in Merlin.net](in Merlin.net)™ Patient Care Network (PCN), including burden trends, episode counters, and histograms, are updated after AI-adjudication.1  \nAI REDUCES  \nTRANSMISSION BURDEN**  \n39.4%  \nreduction in transmissions.14  \nTIME SAVINGS FROM AI  \nAI algorithms can save clinics approximately 486 hours annually for every 100 Assert-IQ™ ICM patients.14  \nThe Assert-IQ ICM is now the only I CM system to combine AI, the longest-lasting Bluetooth® battery life, and IQ Insights to optimize patient management across arrhythmia types.  \n*If selected by healthcare provider  \n**For Patients with at least 1 AF or Pause alert pre-AI  \nThe number of hours that a clinic may save from post-AI burden reduction, based on an analysis of approximately 4,000 U.S. Assert-IQ ICM devices across indications.14  \nThis is calculated as 11 minutes per transmission, plus 0.6 minutes per SEGM.  \nContact your Abbott Sales Representative or visit [cardiovascular. abbott/AssertIQ](cardiovascular. abbott/AssertIQ)  \nReferences  \n1. Abbott. Assert-IQ I CM Artificial Intelligence User Manual.  \n2. Abbott. Assert-IQ I CM User Manual.  \n3. Medtronic. REVEAL LINQ‡ LNQ11 Insertable Cardiac Monitor and Patient Assistant PA96000 Clinician Manual. Updated August 26, 2015. Accessed June 3,2025. [https://manuals.medtronic.com/content/dam/emanuals/crdm/CONTRIB_215651.pdf](https://manuals.medtronic.com/content/dam/emanuals/crdm/CONTRIB_215651.pdf)  \n4. Medtronic. LINQ II ‡ LNQ22 Insertable Cardiac Monitor Clinician Manual. Updated September 01, 2022. Accessed June 3, 2025. [https://manuals.medtronic.com/content/dam/emanuals/crdm/M032283C001B_view.pdf](https://manuals.medtronic.com/content/dam/emanuals/crdm/M032283C001B_view.pdf)  \n5. Boston Scientific. User’s Manual, LUX-Dx‡ Insertable Cardiac Monitor System M301, 2925, 2935. Updated August 2024.  \nAccessed June 3, 2025. [https://www.bostonscientific.com/content/dam/Manuals/us/current-rev-en/51656369-002_LUX](https://www.bostonscientific.com/content/dam/Manuals/us/current-rev-en/51656369-002_LUX)  \nDx_UM_en_S.pdf  \n6. Boston Scientific. User’s Manual, LUX-Dx II ‡, LUX-Dx II+‡ Insertable Cardiac Monitor System M302, M312, 2925, 2929, 2935, 2939. Updated August 2024. Accessed June 3, 2025. [https://www.bostonscientific.com/content/dam/Manuals/us/current-rev](https://www.bostonscientific.com/content/dam/Manuals/us/current-rev)en/51583079-002 _LUX-Dx_UM_en_S.pdf  \n7. Biotronik. Technical Manual BioMonitor III‡. Updated December 10, 2020. Accessed June 3, 2025. [https://manuals.biotronik](https://manuals.biotronik).  \ncom/emanuals-professionals/?country=US&product=ImplCardMon/BioMonitor3/BioMonitor3 _US  \n8. Biotronik. Technical Manual BioMonitor III m‡. Updated December 10, 2020. Accessed June 3, 2025. [https://manuals.biotronik](https://manuals.biotronik).  \ncom/emanuals-professionals/?country=US&product=ImplCardMon/BioMonitor3m/BioMonitor3m_US  \n9. Biotronik. Technical Manual BioMoni","cbCaibnQmaIU4rbA","https://ap.wps.com/l/cbCaibnQmaIU4rbA","pdf",756222,"English","# AI-Powered AF and Pause Detection\n## Reduced False Positives and Maintained True Episode Detection\n## AI Algorithm Workflow and Cloud Adjudication\n## Key Episode Technology and Diagnostics Updates\n## Transmission Burden and Time Savings\n## Indications for Use and Patient Eligibility","[{\"question\":\"How does ASSERT-IQ™ improve AF and pause detection accuracy?\",\"answer\":\"ASSERT-IQ™ ICM uses AI algorithms to enhance the accuracy of AF and pause episode detection, reducing false positives while maintaining high sensitivity. It retains 100% of true AF episodes detected and 99.2% of true pause episodes.\"},{\"question\":\"What workflow does the AI algorithm follow in ASSERT-IQ™ ICM?\",\"answer\":\"The system performs initial detection and transmission of all episodes, then uses AI adjudication in the cloud to remove false episodes. Key episode technology makes true episodes available on Merlin.net, where patient care network diagnostics are updated.\"},{\"question\":\"What impact does ASSERT-IQ™ have on clinician workload and transmissions?\",\"answer\":\"ASSERT-IQ™ reduces transmission burden and can save clinics substantial annual time per 100 patients. For patients with at least 1 AF or pause alert pre-AI, a 39.4% reduction in transmissions is cited.\"}]","ASSERT-IQ™ INSERTABLE CARDIAC MONITOR (I CM) - AI-POWERED AF & Pause Detection | PDF"]