[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-378808-105":59,"doc-detail-378808-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","artificial-intelligence-in-breastscreen-norway-a-retrospective-analysis-of-a-cancer-enriched-sample","Artificial intelligence in BreastScreen Norway - a retrospective analysis of a cancer-enriched sample","","Retrospective evaluation compares an artificial intelligence (AI) malignancy-risk scoring system with independent double reading by radiologists in BreastScreen Norway. The analysis includes screen-detected cancers, interval cancers, and negative examinations from 2010 to 2018, using an AI score of 10 as the decision threshold and stratifying results by mammographic density. The AI assigns a score of 10 to a large share of screen-detected cancers and to substantial proportions of interval cancers, with strongest performance in women with the highest breast density.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/artificial-intelligence-in-breastscreen-norway-a-retrospective-analysis-of-a-cancer-enriched-sample/378808/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/artificial-intelligence-in-breastscreen-norway-a-retrospective-analysis-of-a-cancer-enriched-sample/378808.png","ImageObject",300,407,{"name":92,"@type":93},"Noah","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-23","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",14,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What does the study compare in BreastScreen Norway?","Question",{"text":113,"@type":114},"It compares selected performance measures from an AI system against independent double reading by radiologists for mammographic screening outcomes.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What data and period were analyzed?",{"text":118,"@type":114},"The retrospective study analyzed BreastScreen Norway data from 2010 to 2018, including screen-detected breast cancers, interval cancers, and negative examinations.",{"name":120,"@type":111,"acceptedAnswer":121},"How is the AI risk score used to classify results?",{"text":122,"@type":114},"The AI system scores examinations from 1 to 10 based on malignancy risk, and an AI score of 10 is used as the threshold for the reported comparisons.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},378808,1790375436,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},8796095462418,"https://ap-avatar.wpscdn.com/avatar/80000253c1241d02b47?x-image-process=image/resize,m_fixed,w_180,h_180&k=1778826106357471780","European Radiology (2023) 33:3735–3743  \n[https://doi.org/10.1007/s00330-023-09461-y](https://doi.org/10.1007/s00330-023-09461-y)  \nArtificial intelligence in BreastScreen Norway: a retrospective analysis of a cancer‑enriched sample including 1254 breast cancer cases  \nHenrik Wethe Koch1,2 · Marthe Larsen3 · Hauke Bartsch4 · Kathinka Dæhli Kurz1,5 · Solveig Hofvind3,6  \nReceived: 25 May 2022 / Revised: 13 December 2022 / Accepted: 24 January 2023 / Published online: 14 March 2023 © The Author(s) 2023  \nAbstract  \nObjectives To compare results of selected performance measures in mammographic screening for an artificial intelligence (AI) system versus independent double reading by radiologists.  \nMethods In this retrospective study, we analyzed data from 949 screen-detected breast cancers, 305 interval cancers, and 13,646 negative examinations performed in BreastScreen Norway during the period from 2010 to 2018. An AI system scored the examinations from 1 to 10, based on the risk of malignancy. Results from the AI system were compared to screening results after independent double reading. AI score 10 was set as the threshold. The results were stratified by mammographic density. Results A total of 92.7% of the screen-detected and 40.0% of the interval cancers had an AI score of 10. Among women with a negative screening outcome, 9.1% had an AI score of 10. For women with the highest breast density, the AI system scored 100% of the screen-detected cancers and 48.6% of the interval cancers with an AI score of 10, which resulted in a sensitivity of 80.9% for women with the highest breast density for the AI system, compared to 62.8% for independent double reading. For women with screen-detected cancers who had prior mammograms available, 41.9% had an AI score of 10 at the prior screening round. Conclusions The high proportion of cancers with an AI score of 10 indicates a promising performance of the AI system, particularly for women with dense breasts. Results on prior mammograms with AI score 10 illustrate the potential for earlier detection of breast cancers by using AI in screen-reading.  \nKey Points  \n• The AI system scored 93% of the screen-detected cancers and 40% of the interval cancers with AI score 10.  \n• The AI system scored all screen-detected cancers and almost 50% of interval cancers among women with the highest breast density with AI score 10.  \n•About 40% of the screen-detected cancers had an AI score of 10 on the prior mammograms, indicating a potential for earlier detection by using AI in screen-reading.  \nKeywords Mammography · Breast neoplasm · Mammographic density · Artificial intelligence · Mass screening  \nAbbreviations  \nAI  \nDCISEUSOBINPI  \nVDG  \nArtificial intelligence  \nDuctal carcinoma in situ European Society of Breast Imaging Nottingham Prognostic Index Volpara Density Grade  \nIntroduction  \nBreast cancer is the most common cancer worldwide and the most common cause of cancer related death among women [1] . Early detection through systematic mammographic screening is shown to reduce the incidence of advanced disease and breast cancer mortality [2 , 3] .  \n*  \n1  \n2  \n3  \nSolveig Hofvind  \n[sshh@kreftregisteret.no](sshh@kreftregisteret.no)  \nDepartment of Radiology, Stavanger University Hospital, Stavanger, Norway  \nFaculty of Health Sciences, University of Stavanger, Stavanger, Norway  \nSection for Breast Cancer Screening, Cancer Registry of Norway, Oslo, Norway  \n4 Department of Radiology, Haukeland University Hospital, Bergen, Norway  \n5 Department of Electrical Engineering and Computer Science, Faculty of Science and Technology, The University of Stavanger, Stavanger, Norway  \n6 Department of Health and Care Sciences, Faculty of Health Sciences, The Arctic University of Norway, Tromsø, Norway  \nIn the current screening setting, the radiological accuracy is suboptimal, with a sensitivity below 80% in general and as low as 50% for women with mammographic dense breasts [3–7] . Some of the undetected cance","cbCaifaPIX0zg4iE","https://ap.wps.com/l/cbCaifaPIX0zg4iE","pdf",788134,"English","# Abstract\n## Objectives\n## Methods\n## Results\n## Conclusions\n# Key Points\n# Keywords\n# Abbreviations\n# Introduction","[{\"question\":\"What does the study compare in BreastScreen Norway?\",\"answer\":\"It compares selected performance measures from an AI system against independent double reading by radiologists for mammographic screening outcomes.\"},{\"question\":\"What data and period were analyzed?\",\"answer\":\"The retrospective study analyzed BreastScreen Norway data from 2010 to 2018, including screen-detected breast cancers, interval cancers, and negative examinations.\"},{\"question\":\"How is the AI risk score used to classify results?\",\"answer\":\"The AI system scores examinations from 1 to 10 based on malignancy risk, and an AI score of 10 is used as the threshold for the reported comparisons.\"}]","Artificial intelligence in BreastScreen Norway - a retrospective analysis of a cancer-enriched sample | PDF",1790232514,23,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/2770ffabac3122c056312386d5ccb39d.webp",983,1305,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/26600174c38d9168a5ae5850fb20e6ff.webp",982,1304,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c2c387404a2d877da6466bd3f8aa5b3d.webp",981,1303,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/dead647a878cda1a74853ff5a38b7429.webp",980,1301]