[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-664313-105":59,"doc-detail-664313-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","army-oil-analysis-program-aoap-mobile-laboratory-operators-manual","ARMY OIL ANALYSIS PROGRAM (AOAP) MOBILE LABORATORY - Operator's Manual","","Operator’s Manual for the Army Oil Analysis Program (AOAP) mobile laboratory, providing essential information to operate and maintain the equipment. Includes prominent safety warnings covering high voltage, death or serious injury risks from improper power connection before grounding, hazards from combustible gases during startup and automatic purge, and handling precautions for radioactive materials and pressurized oxygen with oil. Also includes guidance for reporting errors and recommending improvements, plus structured chapters, sections, and appendices.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/army-oil-analysis-program-aoap-mobile-laboratory-operators-manual/664313/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/army-oil-analysis-program-aoap-mobile-laboratory-operators-manual/664313.png","ImageObject",300,407,{"name":92,"@type":93},"asba","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of this operator’s manual for the AOAP mobile laboratory?","Question",{"text":112,"@type":113},"It provides essential information needed to operate and maintain the Army Oil Analysis Program (AOAP) mobile laboratory.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What are the key safety warnings related to electrical power use?",{"text":117,"@type":113},"Death or serious injury may result if personnel connect the main power cable to the laboratory before grounding; deactivate power at the generator set before connecting cables to the connector and do not connect live cables.",{"name":119,"@type":110,"acceptedAnswer":120},"How should personnel handle radioactive materials and what disposal guidance is given?",{"text":121,"@type":113},"The ionizing unit uses polonium and can be a health hazard if ingested; when no longer effective, do not discard as scrap and dispose of it as radioactive material according to existing instructions.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},664313,1793251288,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},3985747872567,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","TM 10-6640-233-10  \nTECHNICAL MANUAL  \nOPERATOR'S MANUAL  \nFOR  \nARMY OIL ANALYSIS PROGRAM  \n(AOAP)  \nMOBILE LABORATORY  \nSEMI-TRAILER MOUNTED  \nNSN 6640-01-254-1699  \nThis technical manual is an authentication of the manufacturer's commercial literature and does not conform with the format and the content requirements normally associated with Army technical manuals. This technical manual does, however, contain all essential information required to operate and maintain the equipment.  \nApproved for public release; Distribution is unlimited.  \nHEADQUARTERS, DEPARTMENT OF THE ARMY  \n26 OCTOBER 1990  \nTM 10-6640-233-10  \nWARNINGS  \nHIGH VOLTAGE  \nis used in the operation of this equipment  \nDEATH ON CONTACT  \nmay result if personnel fail to observe safety precautions  \nDeath or serious injury may result from connecting main power cable to laboratory before grounding.  \nDo not attempt to connect live main power cable to laboratory electrical connector. Deactivate power source at generator set before connecting cable to connector.  \nWARNINGS  \nCOMBUSTIBLE GASES  \nmay be present in the shelter after prolonged periods  \nDEATH OR SERIOUS INJURY  \nmay result if personnel fail to observe safe operating practices.  \nDo not attempt to enter laboratory during laboratory startup until automatic purge cycle (5 minutes) is completed. Dangerous combustible gases or vapors may be present which could ignite and cause death or serious injury to personnel.  \nWARNING  \nRADIOACTIVE MATERIAL  \nThe ionizing unit utilized contains the radioactive isotope polonium which is an alpha emitter and can be a health hazard if ingested. When the unit is no longer effective as a static eliminator, the small quantity of radioactive materials remaining presents a potential hazard if mishandled. Do not discard as scrap. Dispose of as radioactive material in accordance with existing instructions.  \nWARNING  \nPRESSURIZED OXYGEN AND OIL  \nDo not lubricate valves or regulators on compressed gas bottles. Pressurized oxygen and oil can create an explosion that could cause death or injury to personnel.  \na  \nTM 10-6640-233-10  \nWARNING  \nMonobromotrifluoromethane liquid or gas can cause  \nDEATH  \nor serious injury if personnel fail to observe safety precautions.  \n· Inhalation of monobromotrifluoromethane gas (Halon 1301) at concentrations of 5% to 6% for more than 4 or 5 minutes may result in serious cardiac or central nervous system effects.  \n· Liquid Halon 1301 (including the spray in the immediate vicinity of discharge) may freeze the skin (frostbite) on contact. Wear protective clothing and eye protection to avoid such contact. In the event of frostbite, warm the affected area quickly to body temperature. Immerse hands in warm water or place hands in armpits. Get medical attention promptly.  \nFor First Aid Refer to FM 21-1 1.  \nb  \nTECHNICAL MANUAL  \nNO. 10-6640-233-10  \nTM 10-6640-233-10  \nHEADQUARTERS DEPARTMENT OF THE ARMY WASHINGTON, D.C. , 26 October 1990  \nOPERATOR'S MANUAL  \nFOR  \nARMY OIL ANALYSIS PROGRAM (AOAP) MOBILE LABORATORY  \nNSN 6640-01-2541699  \nREPORTING ERRORS AND RECOMMENDING IMPROVEMENTS  \nYou can help improve this manual. If you find any mistakes or if you know of a way to improve the procedures, please let us know. Mail your letter or DA Form 2028 (Recommended Changes to Publications and Blank Forms), on DA Form 2028-2 located in back of this book to: Commander, U.S. Army Troop Support Command, ATTN: AMSTR-MMTS, 4300 Goodfellow Boulevard, St. Louis, MO 63120-1798. A reply will be furnished directly to you.  \nApproved for public release; distribution is unlimited  \nTABLE OF CONTENTS  \nPage  \nCHAPTER 1 INTRODUCTION ................................................................................................................ 1-1  \nSection I General Information ............................................................................................................ 1-1  \nSection II Equipment Description and Data ...............................","cbCaipBF41hsTRaN","https://ap.wps.com/l/cbCaipBF41hsTRaN","pdf",1276020,117,"English","# CHAPTER 1 INTRODUCTION\n## Section I General Information\n## Section II Equipment Description and Data\n## Section III Technical Principles of Operation\n# CHAPTER 2 OPERATING INSTRUCTIONS\n## Section I Operator's Controls and Indicators\n## Section II Operator Preventive Maintenance Checks and Services (PMCS)\n## Section III Operation Under Usual Conditions\n## Section IV Operation Under Unusual Condition\n# CHAPTER 3 OPERATOR MAINTENANCE INSTRUCTIONS\n## Section I Lubrication Instructions\n## Section II Operator Troubleshooting Procedures\n## Section III Operator Maintenance Procedures\n# APPENDIX A REFERENCES\n# APPENDIX B COMPONENTS OF END ITEM AND BASIC ISSUE ITEM LIST\n# APPENDIX C EXPENDABLE/DURABLE SUPPLIES AND MATERIALS LIST\n# APPENDIX D ADDITIONAL AUTHORIZATION LIST","[{\"question\":\"What is the purpose of this operator’s manual for the AOAP mobile laboratory?\",\"answer\":\"It provides essential information needed to operate and maintain the Army Oil Analysis Program (AOAP) mobile laboratory.\"},{\"question\":\"What are the key safety warnings related to electrical power use?\",\"answer\":\"Death or serious injury may result if personnel connect the main power cable to the laboratory before grounding; deactivate power at the generator set before connecting cables to the connector and do not connect live cables.\"},{\"question\":\"How should personnel handle radioactive materials and what disposal guidance is given?\",\"answer\":\"The ionizing unit uses polonium and can be a health hazard if ingested; when no longer effective, do not discard as scrap and dispose of it as radioactive material according to existing instructions.\"}]","ARMY OIL ANALYSIS PROGRAM (AOAP) MOBILE LABORATORY - Operator's Manual | PDF",295]