[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-563096-105":59,"doc-detail-563096-en":124},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":117,"head_meta":119,"extra_data":121,"updated_unix":123},105,"en","arcolectric-2000-series-slide-switches-technical-data","Arcolectric 2000 Series Slide Switches - Technical Data","","This technical documentation provides detailed specifications for the Arcolectric 2000 series slide switches, featuring options for up to 5 positions. The document outlines essential electrical ratings, including 10A 250Vac, and compliance information with UL and CSA standards. It provides comprehensive technical data regarding terminal configurations, body dimensions, and PCB mounting options to ensure compatibility with various industrial applications. Designed for reliability, the 2000 series incorporates inorganic lubrication to maintain integrity, prevent plastic degradation, and ensure stable performance across different operating environments. Detailed diagrams and measurements are included to facilitate precise integration for engineers and designers.",{"@graph":69,"@context":116},[70,84,99],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/arcolectric-2000-series-slide-switches-technical-data/563096/",{"url":83,"name":65,"@type":85,"author":86,"headline":65,"publisher":89,"fileFormat":92,"inLanguage":63,"description":67,"dateModified":93,"datePublished":93,"encodingFormat":92,"isAccessibleForFree":94,"interactionStatistic":95},"DigitalDocument",{"name":87,"@type":88},"moss~","Person",{"url":74,"name":90,"@type":91},"DocShare","Organization","application/pdf","2026-10-12",true,{"@type":96,"interactionType":97,"userInteractionCount":4},"InteractionCounter",{"@type":98},"ViewAction",{"@type":100,"mainEntity":101},"FAQPage",[102,108,112],{"name":103,"@type":104,"acceptedAnswer":105},"What are the primary electrical ratings for the Arcolectric 2000 series slide switches?","Question",{"text":106,"@type":107},"The switches are rated for 10A 250Vac, with specific variations such as 6(3)A 250Vac T85 and UL/CSA ratings of 16A 250Vac non-inductive or 4A 300Vac.","Answer",{"name":109,"@type":104,"acceptedAnswer":110},"What lubrication material is used in the 2000 series switches?",{"text":111,"@type":107},"The 2000 series utilizes inorganic lubrication, which is designed to prevent the degradation of plastics and maintain long-term operational integrity.",{"name":113,"@type":104,"acceptedAnswer":114},"Are there options for mounting stability in the switch design?",{"text":115,"@type":107},"Yes, for PCB mounting applications, the switches feature extra support terminals to enhance structural stability during use.","https://schema.org",{"og:url":83,"og:type":118,"og:title":65,"og:site_name":90,"og:description":67},"article",{"robots":120,"canonical":83},"index,follow",{"doc_id":122,"site_id":62},563096,1791810532,{"code":4,"msg":5,"data":125},{"doc_id":122,"user_id":126,"nickname":87,"user_avatar":127,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":128,"file_id":129,"file_url":130,"file_type":131,"file_size":132,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":133,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":134,"faqs":135,"seo_title":136,"seo_description":67,"update_tm":123,"read_time":24},962090895452,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","2000 Slide Switches-up to 5 position 10A 250Vac  \n10A 250VacT85  \n6(3)A 250VacT85  \nUL CSA 16A 250Vac Non Inductive UL CSA 4A 300Vac  \nUL65°C, file no. E45221, CSA file no. LR10990  \nµ contact gap  \nPlease specify: Standard action (SP116) or Light action (SP118) 2000 series lubrication is inorganic and does not degrade plastics Technical data on pages 4 & 5  \nT 2 2 20 5 C---  \nTERMINAL SERIES POSITIONS CIRCUIT SLIDER BODY PRINT, COLOUR, ETC  \n30  \nTERMINAL  \nK  \n1.3  \n2.8 x 0.8  \nR  \n1.2 3.6*  \n2.8 x 0.8  \nT  \n2.6 6.0* 1.6  \nSolder  \nX  \nPCB 0.8 Sq.  \nY  \n2.6  \nPCB 0.8 Sq. For mounting stability switches have extra“support” terminals  \n* Nominal Dimension varies with body type. For exact figure call factory  \nSERIES  \n2  \ntel: +44 (0)20 8979 3232 • Arcolectric • email: [info@arcoswitch.co.uk](info@arcoswitch.co.uk)  \nBODY  \nDIMENSIONS (mm)  \nOPTIONS  \nColour  \nFor custom slider colours call the factory.  \nA full range is available for large orders  \n2 Position C body 2 Position H body Cut-out /PCB Matrix  \n23.0   \n5.8  \n14.0  \n7.0 7.0  \n6.0 ~~ ~~  \n14.9  \n7.0 7.0  \n  13.3   \n6.3  \n7.07.0  \nfor PCB  \n\n| 3 Position A body\u003Cbr>\u003Cbr> 30.0 \u003Cbr>\u003Cbr>\u003Cbr>5.8\u003Cbr>\u003Cbr>14.0\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>[7.0 7.0 7.0](7.0 7.0 7.0) | 3 Position H body |  22.3 \u003Cbr>6.3\u003Cbr>\u003Cbr>  6.0\u003Cbr>\u003Cbr>\u003Cbr>   Ø1.3\u003Cbr>[7.0 7.0 7.0](7.0 7.0 7.0)[ ](7.0 7.0 7.0)for PCB\u003Cbr>\u003Cbr>|\n| --- | --- | --- |\n|  | \u003Cbr>|  |\n| 4 Position A body\u003Cbr>| 4 Position H body\u003Cbr>|  29.3 \u003Cbr>6.3\u003Cbr>\u003Cbr>7.0 7.0 7.0 7.0\u003Cbr>\u003Cbr>for PCB |\n\n5 Position A body  \n11.0   \n5.8  \n44.0  \n14.0  \n7.0 7.0 7.0 7.07.0  \n36.3   \n6.3  \n6.0  \n    Ø1.3  \n7.0 7.0 7.0 7.0 7.0 for PCB  \n31  \ntel: +44 (0)20 8979 3232 • Arcolectric • email: [info@arcoswitch.co.uk](info@arcoswitch.co.uk)","cbCaigw88pslpbXH","https://ap.wps.com/l/cbCaigw88pslpbXH","pdf",225154,"English","# Terminal Configurations\n## PCB Mounting Details\n# Body Types and Dimensions\n## 2 Position Models\n## 3 Position Models\n## 4 Position Models\n## 5 Position Models","[{\"question\":\"What are the primary electrical ratings for the Arcolectric 2000 series slide switches?\",\"answer\":\"The switches are rated for 10A 250Vac, with specific variations such as 6(3)A 250Vac T85 and UL/CSA ratings of 16A 250Vac non-inductive or 4A 300Vac.\"},{\"question\":\"What lubrication material is used in the 2000 series switches?\",\"answer\":\"The 2000 series utilizes inorganic lubrication, which is designed to prevent the degradation of plastics and maintain long-term operational integrity.\"},{\"question\":\"Are there options for mounting stability in the switch design?\",\"answer\":\"Yes, for PCB mounting applications, the switches feature extra support terminals to enhance structural stability during use.\"}]","Arcolectric 2000 Series Slide Switches - Technical Data | PDF"]