[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-649119-105":59,"doc-detail-649119-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","architectural-drawings-building-location-plan-consultant-directory","Architectural Drawings - Building Location Plan - Consultant Directory","","Building location plan and drawing schedule for the UBC MacMillan Building at 2357 Main Mall, Vancouver, including owner, architectural, mechanical, structural, and asbestos consultant directory details. The document records building code classification (BCBC 2012), legal description, major occupancies, sprinklered and fire alarm system status, construction type, and building height. It lists architectural, mechanical, electrical, and structural drawing sets with key plan, floor plans, elevations, sections, and penthouse details.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/architectural-drawings-building-location-plan-consultant-directory/649119/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/architectural-drawings-building-location-plan-consultant-directory/649119.png","ImageObject",300,407,{"name":92,"@type":93},"awa","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-03","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the building address and location information provided?","Question",{"text":112,"@type":113},"The municipal address is 2357 Main Mall, and the legal description is listed as 015891909, District Lot 3044, Group 1, N.W.D.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which building systems and code classifications are recorded?",{"text":117,"@type":113},"The plan shows Building Code Classification as BCBC 2012, major occupancies as Group A, Div 2, sprinklered as YES, standpipe system as NO, fire alarm system as YES, and construction type as non-combustible.",{"name":119,"@type":110,"acceptedAnswer":120},"What drawing categories are included in the drawing list?",{"text":121,"@type":113},"The drawing list covers Architectural Drawings, Mechanical Drawings, Electrical Drawings, and Structural Notes, with specific sheets for floor plans, elevations, details, and related schedules.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},649119,1792797398,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":24},3985747858093,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","6 BUILDING LOCATION PLAN  \n| PROJECT DIRECTORY |  |\n| --- | --- |\n| OWNER REPRESENTATIVE | UNIVERSITY OF BRITISH COLUMBIA\u003Cbr>PROJECT SERVICES 2329 WEST MALL VANCOUVER, BC, V6T 1Z4 PH: 604.822.5016\u003Cbr>FAX: 604.822.5291\u003Cbr>JAMES CORNELIA, PROJECT MANAGER |\n| ARCHITECT | THE COLBORNE ARCHITECTURAL GROUP\u003Cbr>PACIFIC INC.\u003Cbr>509 RICHARDS STREET, 8TH FLOOR VANCOUVER, BC V6B 2Z6\u003Cbr>PH: 604.669.4166\u003Cbr>FAX: 604.669.4144\u003Cbr>STEPHEN QUIGLEY, ARCHITECT AIBC, MRAIC. |\n| MECHANICAL ENGINEER | BYCAR ENGINEERING LTD MARC MARSDEN, AScT MarcM@bycar.ca |\n| STRUCTURAL ENGINEER | JM ENGINEERING LTD 608-318 HOMER STREET Vancouver, BC V6B 2M6 Ph: 604.683.0595\u003Cbr>Fax: 604.684.0596\u003Cbr>JIM MANDELLI, P. ENG. |\n| ASBESTOS CONSULTANT | ACM ENVIRONMENTAL CORPORATION\u003Cbr>217-2323 QUEBEC STREET Vancouver, BC V5T 4S7\u003Cbr>Ph: 604.873.8599\u003Cbr>Fax: 604.873.5956\u003Cbr>BRIAN SAARELA, CEI |\n\n\n| BUILDING CODE CLASSIFICATION: BCBC\u003Cbr>2012 |  |\n| --- | --- |\n| MUNICIPAL ADDRESS: | 2357 MAIN MALL |\n| LEGAL DESCRIPTION: | 015891909, DISTRICT LOT 3044, GROUP 1, N.W. D. |\n| MAJOR OCCUPANCIES: | GROUP A, DIV 2 |\n| APPLICABLE CODE PART: | PART 3; [3.2.2.23](3.2.2.23) ANY HEIGHT, ANY AREA SPRINKLERED |\n| BUILDING HEIGHT: | 3 STORIES ABOVE + 1 LEVELS BELOW GRADE |\n| NO. OF STREETS FACING: | 2 |\n| SPRINKLERED: | YES |\n| STANDPIPE SYSTEM: | NO |\n| CONSTRUCTION TYPE: | NON-COMBUSTIBLE |\n| FIRE ALARM SYSTEM: | YES |\n| EMERGENCY POWER: | ? |\n| CURRENT USE: | ACADEMIC |\n| PROPOSED USE: | NO CHANGE |\n| FLOOR AREA CALCULATIONS: |  |\n| ROOF AREA | 33,815 SQ. FT. |\n|  |  |\n\nDRAWING LIST  \nARCHITECTURAL DRAWINGS  \nA000 GENERAL NOTES, DRAWING LIST,  \nPROJECT DATA, SITE PLAN,  \nEXISTING/PROPOSED PHOTOS  \nCONSULTANT DIRECTORY  \nA100 PROPOSED FLOOR PLAN, ELEVATIONS AND DETAILS  \nMECHANICAL DRAWINGS  \nM1 LEGEND & DETAILS  \nM2 FLOOR PLANS  \nM3 EXHAUST SYSTEM DETAILS  \nM4 AIR BALANCE, CONTROL NOTES M5 SPECS AND CHECK SHEET  \nELECTRICAL DRAWINGS  \nE1 KEY PLAN AND SPECIFICATIONS  \nE2 CONSTRUCTION DETAILS  \nSTRUCTURAL NOTES SSK 01  \nUBC MACMILLAN BUILDING FUMEHOODS  \n2357 Main Mall, Vancouver  \nB.C. V6T 1Z4  \nGENERAL NOTES, DRAWING LIST  \nPROJECT DATA, SITE PLAN EXISTING/PROPOSED PHOTOS  \nAugust 7, 2014  \nAS NOTED  \nAM  \nSQ  \n1403  \nA000  \n1403-A000 .dwg R-  \n| \u003Cbr>\u003Cbr>\u003Cbr>ENTRY\u003Cbr>102\u003Cbr>WASH-UP\u003Cbr>102B\u003Cbr>GLASS\u003Cbr>STORAGE\u003Cbr>102C\u003Cbr>1 FLOOR PLAN\u003Cbr>\u003Cbr>| EXISTING WEST ELEVATION\u003Cbr>\u003Cbr>\u003Cbr>PROPOSED WEST ELEVATION\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>MILLWORK SCHEDULE EXISTING FUME HOOD TO BE SUPPLIED BY UBC. INSTALLED BY QUALIFIED TRADE, SEE MECHANICAL SPECIFICATION TAG NEW STORAGE SYSTEM COLOUR 1 MOTT STEEL\u003Cbr>CASEWORK 36 IN. WIDE ACID STORAGE CABINET WITH 2 DOORS WARM WHITE 2 36 IN. WIDE ACID STORAGE CABINET WITH 2 DOORS WARM WHITE 3 30 IN. WIDE SINK UNIT WITH 2 DOORS REF:1318022 WARM WHITE 4 30 IN. WIDE WITH 2 DOORS & TOP DRAWERS REF:1310023 WARM WHITE 5 MOTT STEEL\u003Cbr>CASEWORK\u003Cbr>(OPTION) 30 IN. WIDE WITH 2 DOORS & TOP DRAWERS REF:1310023 WARM WHITE 6 MOTT STEEL\u003Cbr>CASEWORK\u003Cbr>(OPTION) 30 IN. WIDE WITH 2 DOORS & TOP DRAWERS REF:1310023 WARM WHITE SINK 18'x16\"x10\" STAINLESS STEEL BOWL SINK TAP. 18\" GOOSENECK FAUCET FOR LAB USE\u003Cbr>\u003Cbr>| |  |  |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n|  |  | \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>|  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  |  |\n|  |  | | | |  | |\n|  |  |  | | |  | |\n| \u003Cbr>\u003Cbr>6 BUILDING SECTION\u003Cbr>\u003Cbr>| \u003Cbr>\u003Cbr>7 MECHANICAL PENTHOUSE DETAILS\u003Cbr>\u003Cbr>\u003Cbr>| |  | |  | |\n|  |  | \u003Cbr>|  |  |  |  |\n|  |  | UBC MACMILLAN BUILDING\u003Cbr>FUMEHOODS 2357 Main Mall, Vancouver\u003Cbr>B.C. V6T 1Z4 |  |  |  |  |\n|  |  | FLOOR PLAN, BUILDING SECTION INTERNAL ELEVATIONS PENTHOUSE DETAILS |  |  |  |  |\n|  |  | August 7, 2014 |  |  | \u003Cbr>A100 |  |\n|  |  | AS NOTED |  |  |  |  |\n|  |  | AM |  |  |  |  |\n|  ","cbCaicdCFfC5lygJ","https://ap.wps.com/l/cbCaicdCFfC5lygJ","pdf",866526,"English","# Building Location Plan\n## Project Directory\n## Building Code Classification and Site Information\n## Drawing List - Architectural, Mechanical, Electrical, Structural\n## Floor Plan, Elevations, Sections, and Penthouse Details","[{\"question\":\"What is the building address and location information provided?\",\"answer\":\"The municipal address is 2357 Main Mall, and the legal description is listed as 015891909, District Lot 3044, Group 1, N.W.D.\"},{\"question\":\"Which building systems and code classifications are recorded?\",\"answer\":\"The plan shows Building Code Classification as BCBC 2012, major occupancies as Group A, Div 2, sprinklered as YES, standpipe system as NO, fire alarm system as YES, and construction type as non-combustible.\"},{\"question\":\"What drawing categories are included in the drawing list?\",\"answer\":\"The drawing list covers Architectural Drawings, Mechanical Drawings, Electrical Drawings, and Structural Notes, with specific sheets for floor plans, elevations, details, and related schedules.\"}]","Architectural Drawings - Building Location Plan - Consultant Directory | PDF"]