[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-383246-105":59,"doc-detail-383246-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","appropriate-screening-mammography-method-for-patients-with-breast-implants-research-report","Appropriate screening mammography method for patients with breast implants - Research report","","Evaluates the benefits and losses of screening mammography with and without implant displacement (ID) and proposes an imaging protocol for patients with breast implants. Mammograms from 162 breasts in 96 patients were reviewed using clinical image quality criteria for positioning and resolution. Standard MLO showed higher positioning scores but lower resolution, kVp, mAs, and compressed breast thickness than ID MLO. ID MLO alone supported sufficient MLO projection with reduced radiation dose while maintaining breast cancer detection capability, especially for dense breasts with subpectoral implants.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/appropriate-screening-mammography-method-for-patients-with-breast-implants-research-report/383246/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/appropriate-screening-mammography-method-for-patients-with-breast-implants-research-report/383246.png","ImageObject",300,407,{"name":92,"@type":93},"mieayamfan","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-24","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",14,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What was the goal of the study on mammography for patients with breast implants?","Question",{"text":113,"@type":114},"To assess the benefits and losses of mammography with and without implant displacement and to propose an appropriate screening imaging protocol.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How did standard MLO and ID MLO images compare in clinical image quality?",{"text":118,"@type":114},"Standard MLO had significantly higher scores for proper positioning but significantly lower scores for image resolution than ID MLO.",{"name":120,"@type":111,"acceptedAnswer":121},"What imaging protocol did the study recommend for screening?",{"text":122,"@type":114},"For patients with breast implants, an ID MLO view alone was considered sufficient for MLO projection while reducing radiation dose without compromising cancer detection, especially in dense breasts with subpectoral implants.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},383246,1790465991,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":44,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962090893677,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nAppropriate screening mammography method for patients with breast implants  \nJihee Park, Eun Young Ko*, Boo‑Kyung Han, Eun Sook Ko, Ji Soo Choi & Haejung Kim  \nIn this study, we aimed to evaluate the benefits and losses of mammography with and without implant displacement (ID) and propose an appropriate imaging protocol for the screening of breasts with implants. We evaluated mammograms of 162 breasts in 96 patients including 71 breasts with biopsy‑proven cancers. Mammography of each breast included standard MLO and ID MLO images. We reviewed the mammograms using clinical image quality criteria, which consist of parameters that evaluate the proper positioning of the breast and the image resolution. Standard MLO images showed significantly higher scores for proper positioning but showed significantly lower scores for image resolution thanthe ID MLO images. Moreover, standard MLO images showed significantly higher kVp, mAs, and compressed breast thickness thanthe ID MLO images. The organ dose was also higher in the standard MLO images than in the ID MLO images, but the difference was not statistically significant. In mammography with proven cancer, ID MLO images showed significantly higher degree of cancer visibility than standard MLO images. For screening mammography in patients with breast implants, ID MLO view alone is sufficient for MLO projection with reducing the patient’s radiation dose without compromising the breast cancer detection capability, especially in dense breasts with subpectoral implants.  \nScreening mammography is the most widely used breast cancer screening tool and is the only imaging modality proven to significantly lower breast cancer mortality1. Guidelines for obtaining screening mammography images are relatively clear and widely followed. Two standard views for each breast, namely the craniocaudal (CC) and mediolateral oblique (MLO) views, are the most commonly used imaging techniques2,3. However, the imaging guidelines for screening mammography in patients with breast implants remain unclear4. Therefore, different sets of mammograms are usually acquired for screening patients with breast implants. Depending on the institution, standard mammography for screening may include four images without implants in both CC and MLO views, eight images with and without implants in both CC and MLO views, or six images consisting of four images with and without implants in MLO view and two images without implants in CC view.  \nThere are reports that mammography with implants incurs a higher radiation dose than mammography without implants5. Current imaging protocols in many institutions include mammography with implants, as it is unclear whether they are more beneficial for cancer detection. Studies comparing the benefits and losses of mammography with and without implants with respect to and in relation to mammography image quality or performance for breast cancer detection are rare. Available published studies have only compared the radiation dose according to mammography techniques5. Even if mammography with implants has a higher radiation dose, it may still be of benefit if the images provide additional information that increases the ease of breast cancer detection. On the contrary, if there is little benefit for cancer detection than considering the higher radiation dose, the images should not be used for screening. To date, research data to support evidence-based decisionmaking is lacking.  \nThe lack of guidance has led to wide variations in mammography practice for breasts with implants. As a result, heterogeneous examinations, with varying image quality and radiation doses, may be of concern6.  \nThis study aimed to evaluate the benefits and losses of mammography with and without implant displacement and to propose an appropriate imaging protocol for screening mammography of breasts with implants.  \nDepartment of Radiology, Center ","cbCaitrvDsHX2o97","https://ap.wps.com/l/cbCaitrvDsHX2o97","pdf",1142939,"English","# Methods\n## Subjects\n## Mammogram acquisition","[{\"question\":\"What was the goal of the study on mammography for patients with breast implants?\",\"answer\":\"To assess the benefits and losses of mammography with and without implant displacement and to propose an appropriate screening imaging protocol.\"},{\"question\":\"How did standard MLO and ID MLO images compare in clinical image quality?\",\"answer\":\"Standard MLO had significantly higher scores for proper positioning but significantly lower scores for image resolution than ID MLO.\"},{\"question\":\"What imaging protocol did the study recommend for screening?\",\"answer\":\"For patients with breast implants, an ID MLO view alone was considered sufficient for MLO projection while reducing radiation dose without compromising cancer detection, especially in dense breasts with subpectoral implants.\"}]","Appropriate screening mammography method for patients with breast implants - Research report | PDF",1790255507,23,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6c669a4c8ca19dbdfca43b3a8f2639bb.webp",983,1291,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c9a5fab14278eb141503065fe1adab16.webp",982,1290,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/e5fae64f7d13d2407be810dd8755cd06.webp",981,1289,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/0a35239e115454401014767406f8949d.webp",980,1287]