[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-466165-105":59,"doc-detail-466165-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","application-of-photo-fenton-process-to-highly-saline-water-matrices-effect-of-inorganic-ions-on-iron-speciation","Application of Photo-Fenton Process to Highly Saline Water Matrices - Effect of Inorganic Ions on Iron Speciation","","Photo-Fenton is widely used for organic pollutant removal and disinfection, but its performance decreases in complex matrices typical of advanced oxidation scenarios. The study reviews how inorganic ions in highly saline water (chlorides, fluorides, bromides, sulphates, carbonates, bicarbonates, borates, phosphates, and nitrates/nitrites, >1 g L−1) affect iron speciation and scavenging behavior in Fenton-based systems. It synthesizes evidence on efficiency for microcontaminant abatement and disinfection, including the most relevant works and industrially relevant contexts.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/application-of-photo-fenton-process-to-highly-saline-water-matrices-effect-of-inorganic-ions-on-iron-speciation/466165/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/application-of-photo-fenton-process-to-highly-saline-water-matrices-effect-of-inorganic-ions-on-iron-speciation/466165.png","ImageObject",300,407,{"name":92,"@type":93},"Nguyễn Văn Học","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-01","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why does the photo-Fenton process efficiency drop in complex matrices?","Question",{"text":112,"@type":113},"Efficiency decreases because multiple matrix components interfere with the process, altering iron speciation and related reaction pathways.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How do inorganic ions in highly saline water influence photo-Fenton performance?",{"text":117,"@type":113},"They can change iron’s coordination environment, modify Fe(II) regeneration rates, and act as scavengers that alter reactive oxygen species identities and yields.",{"name":119,"@type":110,"acceptedAnswer":120},"What is the reported impact of phosphates and nitrates/sulphates on Fenton reactivity?",{"text":121,"@type":113},"Phosphates form poorly soluble iron phosphate (FePO4) and completely suppress Fenton reactivity, while nitrates and sulphates show negligible interaction even at high concentrations.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},466165,1791052473,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":26,"preview_page_count":19,"preview_urls":145},1374402739827,"https://ap-avatar.wpscdn.com/avatar/14000c97e7351f1a627?x-image-process=image/resize,m_fixed,w_180,h_180&k=1787885694763230660","Review  \nApplication of Photo-Fenton Process to Highly Saline Water Matrices: Effect of Inorganic Ions on Iron Speciation  \nIvan Vallés 1, Javier Moreno-Andrés 2, Iván Sciscenko 1,3, Lucas Santos-Juanes 1 and Antonio Arques 1, *  \nAcademic Editor: Javier Llanos  \nReceived: 13 October 2025  \nRevised: 3 December 2025  \nAccepted: 16 December 2025  \nPublished: 23 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Grupo de Procesos de Oxidación Avanzada, Departamento de Ingeniería Textil y Papelera, Universitat Politècnica de València, Campus de Alcoy, 03801 Alcoy, Spain; [ivvalfer@epsa.upv.es](ivvalfer@epsa.upv.es) (I.V.); ivanmatias.sciscenko@unito.it (I.S.); [lusanju1@txp.upv.es](lusanju1@txp.upv.es) (L.S.-J.)  \n2 Department of Environmental Technologies, Faculty of Marine and Environmental Sciences, INMAR-Marine Research Institute, CEIMAR-International Campus of Excellence of the Sea, University of Cadiz, Campus Universitario de Puerto Real, 11510 Cádiz, Spain; [javier.moreno@uca.es](javier.moreno@uca.es)  \n3 Department of Chemistry, University of Turin, Via Pietro Giuria 5, 10125 Turin, Italy  \n* Correspondence: aarques@txp.upv.es  \nAbstract  \nThe photo-Fenton process has been widely studied for the treatment of organic pollutants and disinfection in a wide range of scenarios. Nevertheless, its efficiency decreased when applied to complex matrices, as in the case of most advanced oxidation processes. Despite the interferences caused by different anions, the photo-Fenton is able to obtain good degradation values for pollutants and microorganisms, especially in combination with other methods; however, it depends on the matrix to be treated. Due to the lack of studies and reviews in this field, this paper reviewed the outcome of the inorganic ions present on highly saline water matrices (more than 1 g L−1 of chlorides, fluorides, bromides, sulphates, carbonates or bicarbonates, borates, phosphates and nitrates/nitrites) on the Fenton-based processes, focusing on their outcome on iron speciation and their scavenger effect. Also, the most relevant works so far for the abatement of microcontaminants and disinfection by this process on highly saline matrices have been revised. Special emphasis is on the efficiency of the process, considering the relevant industries referred to.  \nKeywords: iron complexation; radical scavenging; inorganic anions; pollutant degradation; disinfection  \n1. Introduction  \nAdvanced oxidation processes (AOPs) have gained considerable attention for wastewater remediation, and among them, Fenton and related treatments stand out due to their operational simplicity and their ability to degrade recalcitrant pollutants [1] . Although the fundamentals of the Fenton reaction have been extensively described, some mechanistic aspects of Fenton chemistry are still under discussion, and alternative pathways have been proposed [2–4] . Nevertheless, it is widely accepted that Equations (1) and (2) govern the catalytic cycle [5]:  \nFe2+ + H2O2 → Fe3+ + HO − + HO• (1)  \nFe3+ + H2O2 → Fe2+ + HO2• + H+ (2)  \nBecause Equation (2) is approximately five orders of magnitude slower than Equation (1), Fe(III) reduction becomes the rate-limiting step of the process [6] . Under irradiation (λ \u003C 530 nm), however, Fe(III) photoreduction is accelerated by ligand-to-metal  \ncharge transfer (LMCT), as shown in Equation (3) [7] . This photochemical enhancement defines the photo-Fenton reaction, whose efficiency strongly depends on the concentration of Fe(OH)2+ , maximised at pH 2.8 [8], typically considered the optimal pH for this process [9] .  \nFe(OH)2+ + hν → Fe2+ + HO• (3)  \nAs pH deviates from 2.8, the relative abundance of Fe(OH)2+ decreases sharply and photo-Fenton efficiency drops accordingly. Above pH 4, Fe(III) rapidly precipitates as (oxo)hydroxides, interru","cbCaisW7Vvmpefsc","https://ap.wps.com/l/cbCaisW7Vvmpefsc","pdf",895361,24,"English","# Abstract\n# Keywords\n# 1. Introduction\n## Fenton catalytic cycle and photoenhancement","[{\"question\":\"Why does the photo-Fenton process efficiency drop in complex matrices?\",\"answer\":\"Efficiency decreases because multiple matrix components interfere with the process, altering iron speciation and related reaction pathways.\"},{\"question\":\"How do inorganic ions in highly saline water influence photo-Fenton performance?\",\"answer\":\"They can change iron’s coordination environment, modify Fe(II) regeneration rates, and act as scavengers that alter reactive oxygen species identities and yields.\"},{\"question\":\"What is the reported impact of phosphates and nitrates/sulphates on Fenton reactivity?\",\"answer\":\"Phosphates form poorly soluble iron phosphate (FePO4) and completely suppress Fenton reactivity, while nitrates and sulphates show negligible interaction even at high concentrations.\"}]","Application of Photo-Fenton Process to Highly Saline Water Matrices - Effect of Inorganic Ions on Iron Speciation | PDF",1790770688,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1be72f38898b6710a52c3dd44d719c56.webp",983,1390,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2339e16ccc2a6a42cd1ad5e777d0dfa3.webp",982,1388,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6970d256101a9e3db44efbf4c09a16d1.webp",981,1387,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/194268e32e1ad4bc9231efe7f652c2b8.webp",980,1385]