[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-561586-105":59,"doc-detail-561586-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","application-note-u-100a-uc3842345-current-mode-control","APPLICATION NOTE U-100A - UC3842/3/4/5 Current-Mode Control","","APPLICATION NOTE U-100A explains current-mode PWM control using the UC3842/3/4/5 family, focusing on low-cost current-mode operation for power supply design. It contrasts current-mode control with conventional pulse-width schemes by describing how an error signal sets peak inductor current through a fixed-frequency pulse train. The note details performance advantages such as improved line regulation via feed-forward, simplified small-signal modeling, and simpler compensation. It also covers current limiting, parallel operation with equal current sharing, and a selection guide for the UC3842/3/4/5 control ICs.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/application-note-u-100a-uc3842345-current-mode-control/561586/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/application-note-u-100a-uc3842345-current-mode-control/561586.png","ImageObject",300,407,{"name":92,"@type":93},"Franzy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"How does the UC3842/3/4/5 current-mode controller terminate each power pulse?","Question",{"text":113,"@type":114},"A clock starts pulses at a fixed frequency, and each pulse ends when an analog of the inductor current reaches a threshold set by the error signal, so the error signal effectively controls peak inductor current.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What performance advantages come from using current-mode control?",{"text":118,"@type":114},"It provides input voltage feed-forward for excellent line regulation and allows the inductor to be treated like a current source for small-signal analysis when current is continuous, simplifying compensation and improving dynamic response.",{"name":120,"@type":111,"acceptedAnswer":121},"How is current limiting implemented in current-mode control with this family?",{"text":122,"@type":114},"Pulse-by-pulse limiting is inherent in the control scheme, and an upper limit on peak current can be set by clamping the error voltage, enabling accurate current limiting.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},561586,1791889684,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},2336478945519,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","U-100A APPLICATION NOTE  \nUC3842/3/4/5 PROVIDES LOW-COST  \nCURRENT-MODE CONTROL  \nINTRODUCTION CURRENT-MODE CONTROL  \nThe fundamental challenge of power supply design is to simultaneously realize two conflicting objectives: good electrical performance and low cost. The  is an integrated pulse width modulator  designed with both these objectives in mind. This  provides designers an inexpensive controller with which they can obtain all the performance advantages of current mode operation. In addition, the UC3842 series is optimized for efficient power sequencing of off-line converters, DC to DC regulators and for driving power MOSFETs or transistors. This application note provides a functional description of the UC3842 family and highlights the features of each individual member, the UC3842, UC3843, UC3844 and UC3845 Throughout the text, the UC3842 part number will be referenced, however the generalized circuits and performance characteristics apply to each member of the UC3842 series unless otherwise noted. A review of current mode control and its benefits is included and methods of avoiding common pitfalls are mentioned. The final section presents designs of power supplies utilizing UC3842 control.  \nFigure 1 shows the two-loop current-mode control system in a typical buck regulator application. A clock signal initiates power pulses at a fixed frequency. The termination of each pulse occurs when an analog of the inductor current reaches a threshold established by the error signal. In this way the error signal actually controls peak inductor current. This contrasts with conventional schemes in which the error signal directly controls pulse width without regard to inductor current.  \nSeveral performance advantages result from the use of current-mode control. First, an input voltage feed-forward characteristic is achieved; i.e. , the control circuit instantaneously corrects for input voltage variations without using up any of the error amplifier’s dynamic range. Therefore, line regulation is excellent and the error amplifier can be dedicated to correcting for load variations exclusively. For converters in which inductor current is continuous, controlling peak current is nearly equivalent to controlling average current. Therefore, when such converters employ current-mode control, the inductor can be treated as an  \nFigure 1. Two-Loop Current-Mode Control System  \nAPPLICATION NOTE U-100A  \nerror-voltage-controlled-current-source for the purposes of small-signal analysis. This is illustrated by Figure 2. The two-pole control-to-output frequency response of these converters is reduced to a single-pole (filter capacitor in parallel with load) response. One result is that the error amplifier compensation can be designed to yield a stable closed-loop converter response with greater gainbandwidth than would be possible with pulse-width control, giving the supply improved small-signal dynamic response to changing loads. A second result is that the error amplifier compensation circuit becomes simpler, as illustrated in Figure 3. Capacitor  and resistor  in Figure 3a add a low frequency zero which cancels one of the two control-to- . output poles of non-current-mode converters. For largesignal load changes, in which converter response is limited by inductor slew rate, the error amplifier will saturate while the inductor is catching up with the load. During this time,  will charge to an abnormal level. When the inductor current reaches its required level, the voltage on   \ncauses a corresponding error in supply output voltage. The recovery time is  which may be quite long. However, the compensation network of Figure  can be used where current-mode control has eliminated the inductor pole. Large-signal dynamic response is then greatly im  \nproved due to the absence of   \nCurrent limiting is greatly simplified with current-mode control. Pulse-by-pulse limiting is, of course, inherent in the control scheme. Furthermore, an upper limit on the pe","cbCaidWw6z5chPPk","https://ap.wps.com/l/cbCaidWw6z5chPPk","pdf",520159,15,"English","# Introduction\n## Current-Mode Control System Operation\n## Performance Advantages and Compensation\n## Current Limiting and Parallel Operation\n# UC3842/3/4/5 Series Description and Features\n## IC Selection Guide","[{\"question\":\"How does the UC3842/3/4/5 current-mode controller terminate each power pulse?\",\"answer\":\"A clock starts pulses at a fixed frequency, and each pulse ends when an analog of the inductor current reaches a threshold set by the error signal, so the error signal effectively controls peak inductor current.\"},{\"question\":\"What performance advantages come from using current-mode control?\",\"answer\":\"It provides input voltage feed-forward for excellent line regulation and allows the inductor to be treated like a current source for small-signal analysis when current is continuous, simplifying compensation and improving dynamic response.\"},{\"question\":\"How is current limiting implemented in current-mode control with this family?\",\"answer\":\"Pulse-by-pulse limiting is inherent in the control scheme, and an upper limit on peak current can be set by clamping the error voltage, enabling accurate current limiting.\"}]","APPLICATION NOTE U-100A - UC3842/3/4/5 Current-Mode Control | PDF",1791806309,38,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/fe381c34a361a6518bee484c11c73c6c.webp",983,1343,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/8a779d8289459dfea908ef5d853b1fcf.webp",982,1368,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/827040911d3e1af1b02d5cdb0cdc977f.webp",981,1297,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ff2e4f0d474330706851817ef278b958.webp",980,1261]