[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-496949-105":59,"doc-detail-496949-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","application-note-342-determination-of-pcbs-in-large-volume-fish-tissue-samples-using-accelerated-solvent-extraction-ase","Application Note 342 - Determination of PCBs in Large-Volume Fish Tissue Samples Using Accelerated Solvent Extraction (ASE)","","Application Note 342 presents an automated approach for extracting and determining polychlorinated biphenyls (PCBs) from large-volume fish tissue samples using accelerated solvent extraction (ASE). ASE replaces solvent-intensive methods such as Soxhlet and sonication by using elevated temperature and controlled pressure to improve extraction efficiency. An ASE 300 system with large sample cells enables 30 g raw tissue extraction under selective or nonselective conditions. Selective conditions using alumina reduce coextracted lipid cleanup demands while maintaining high recoveries and precision for GC/ECD quantification.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/application-note-342-determination-of-pcbs-in-large-volume-fish-tissue-samples-using-accelerated-solvent-extraction-ase/496949/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/application-note-342-determination-of-pcbs-in-large-volume-fish-tissue-samples-using-accelerated-solvent-extraction-ase/496949.png","ImageObject",300,407,{"name":92,"@type":93},"Lucas Martin","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-10-02",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is ASE used for PCB extraction from fish tissue?","Question",{"text":112,"@type":113},"ASE improves extraction efficiency by using higher temperatures than traditional techniques and provides good recoveries for naturally occurring PCBs. It also supports automation, which helps when analyzing many samples.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the benefit of using selective ASE conditions?",{"text":117,"@type":113},"Selective extraction uses alumina to remove coextracted lipid material, producing extracts that can often be analyzed without laborious cleanup steps prior to GC analysis.",{"name":119,"@type":110,"acceptedAnswer":120},"How are extracted PCBs quantified in this method?",{"text":121,"@type":113},"Extracts are dried, concentrated, and analyzed by GC with an electron capture detector (ECD). External standard calibration with replicate samples and duplicate injections is used to determine recoveries and precision.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},496949,1792183886,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":39,"preview_page_count":81,"preview_urls":144},8796095360427,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Application Note 342  \nDetermination of PCBs in  \nLarge-Volume Fish Tissue Samples  \nUsing Accelerated Solvent Extraction (ASE)  \nIntroductIon  \nExtraction and analysis of PCBs from fish and other marine tissues continues to be a necessary step in the monitoring of the aquatic food supply. Due to the large number of samples requiring analysis, automated extraction systems have proven useful in this area. ASE technology has been shown to produce good recoveries of naturally occurring PCBs from fish tissue samples,1,2,3 and is approved for use in U.S. EPA SW-846 Method 3545 for the extraction of PCBs, OCPs, BNAs, OPPs, herbicides, and dioxins and furans.4 ASE was designed to replace time-consuming and solvent-intensive methods such as Soxhlet and sonication in the environmental area. ASE operates at temperatures higher than those possible in traditional techniques, thus increasing the efficiency of the extraction process.  \nThe continued need for lower analyte detection limits in monitoring the bioaccumulation of priority organic pollutants (POPs) has resulted in the use of large sample sizes. Many automated extraction systems are limited in their ability to extract large samples; however; the ASE 300 extraction system was designed for these larger sample size applications. With sample cell sizes of 34, 66, and 100 mL, it can extract 30-g samples of raw fish tissue under both selective and nonselective conditions. Under nonselective conditions, the extracts produced are similar in composition those from traditional methods and require the usual cleanup steps prior to GC analysis. Using selective ASE conditions, extracts can be produced that are free of coextracted lipid material. These sample extracts can be analyzed without laborious and timeconsuming cleanup steps.  \nEquIpmEnt  \nDionexASE 300 Accelerated Solvent Extractor* equipped with 100-mL cells  \nDionex bottles (250 mL) for collection of extracts (P/N 056785)  \nCellulose filters (P/N 056780)  \nGas Chromatograph equipped with electron capture detector (ECD)  \n*ASE 150 and 350 can be used for equivalent results  \nrEagEntsand standards  \nMethylene chloride (Optima Grade, Fisher Scientific) ASE Prep DE (diatomaceous earth) (P/N 062819) Alumina (basic, Brockman activity I, Fisher Scientific) PCB standards (ULTRA Scientific)  \nsamplE prEparatIon  \nThirty grams of raw fish tissue (cod fillet, purchased locally) was weighed out and spiked with 50 µL ofa PCB congener standard solution (ULTRA Scientific) in hexane, containing 50–250 µg/mL individual PCB congeners. This resulted in a final sample concentration of 80–400 ng/g. The samples were mixed with 20 g ofASE Prep DE in amortar and pestle and then loaded into 100-mL cells containing 10 g of alumina and a cellulose filter.  \nExtractIon condItIons  \nExtraction Solvent: Methylene chloride  \nTemperature: 125 °C  \nPressure: 1500 psi*  \nHeatup Time: 5 min  \nStatic Time: 3 min  \nFlush Volume: 60%  \nPurge Time: 120 s  \nStatic Cycles: 3  \nTotal Extraction Time: 18 min per sample  \nTotal Solvent Use: 120–140 mL per sample  \n*Pressure studies show that 1500 psi is the optimum extraction pressure for allASE applications.  \npost ExtractIon  \nSample extracts were dried by sodium sulfate treatment, concentrated to 10 mL under nitrogen, and analyzed by GC/ECD. Sodium sulfate treatment can be performed in traditional cartridges or funnels, or simply added to the extraction bottle and shaken.  \nquantIfIcatIon  \nAnalysis was performed using a gas chromatograph equipped with an ECD. A fused silica 30 m × 0.32 mm column was used. The injector was maintained at 280 °Cand the detector at 300 °C. Temperature programming was performed from 100 to 300 °C (5 min) at 15 °C/min after a 1 min hold. Recoveries were determined by external standard calibration (three levels) with five replicate samples and duplicate GC injections.  \nrEsults and dIscussIon  \nThe fish tissue used in this study was cod fillet obtained from a local source. The sample had a fat con","cbCaiiZz5x7zTVrR","https://ap.wps.com/l/cbCaiiZz5x7zTVrR","pdf",379995,"English","# IntroductIon\n# EquIpmEnt\n# rEagEntsand standards\n# samplE prEparatIon\n# ExtractIon condItIons\n# post ExtractIon\n# quantIfIcatIon\n# rEsults and dIscussIon\n# conclusIon\n# rEfErEncEs","[{\"question\":\"Why is ASE used for PCB extraction from fish tissue?\",\"answer\":\"ASE improves extraction efficiency by using higher temperatures than traditional techniques and provides good recoveries for naturally occurring PCBs. It also supports automation, which helps when analyzing many samples.\"},{\"question\":\"What is the benefit of using selective ASE conditions?\",\"answer\":\"Selective extraction uses alumina to remove coextracted lipid material, producing extracts that can often be analyzed without laborious cleanup steps prior to GC analysis.\"},{\"question\":\"How are extracted PCBs quantified in this method?\",\"answer\":\"Extracts are dried, concentrated, and analyzed by GC with an electron capture detector (ECD). External standard calibration with replicate samples and duplicate injections is used to determine recoveries and precision.\"}]","Application Note 342 - Determination of PCBs in Large-Volume Fish Tissue Samples Using Accelerated Solvent Extraction (ASE) | PDF",1790944434,[145,149,153],{"page_no":8,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/551dbc964e56c50c31bb8cff5ade0efa.webp",983,1272,{"page_no":14,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d8fbe0fb82eb0b4a24f9a09f8a1ae082.webp",982,1270,{"page_no":81,"url":154,"width":155,"height":156},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c3af342572a90b70d678449024e85472.webp",981,1269]