[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-665584-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-665584-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","apg-accessible-restrooms-ada-accessibility-requirements","APG-Accessible-Restrooms - ADA Accessibility Requirements","","2010 ADA Standards and 2009 ICC/ANSI Standards guidance outlines how to design restroom elements that meet accessibility requirements. The content specifies the need to follow the most stringent applicable standard for ADA projects and highlights compliant product features such as automatic soap dispensers, recessed accessories, vendor compliance, and grab bar layouts. It details clear floor space dimensions and approaches, mounting height limits for operable parts, turning space types, and special lavatory clearances. It also defines control and operability requirements, including one-hand use, low force, and centered placement for left- and right-hand access.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/apg-accessible-restrooms-ada-accessibility-requirements/665584/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/apg-accessible-restrooms-ada-accessibility-requirements/665584.png","ImageObject",300,407,{"name":42,"@type":43},"naya.afterrain","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-29",true,{"@type":52,"interactionType":53,"userInteractionCount":22},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"Which accessibility standards must be followed for ADA restroom projects?","Question",{"text":62,"@type":63},"Follow the most stringent of the applicable ADA, ICC A117 .1, and state accessibility standards to ensure full compliance.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What are the key clear floor space requirements for a single wheelchair?",{"text":67,"@type":63},"Provide at least 30\" x 48\" clear floor space and position it for forward approach at lavatories, urinals, and baby changing stations, allowing both left- and right-hand access.",{"name":69,"@type":60,"acceptedAnswer":70},"What operability and force limits apply to restroom controls?",{"text":71,"@type":63},"Controls must be operable with one hand without tight grasping, pinching, or twisting, and must require less than 5 lbs. of force, with controls centered over sufficient clear floor space for both approaches.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},665584,1793305040,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},7,40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":79,"read_time":144},962094248482,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","2010 ADA Standards  \n2009 ICC/ANSI Standards  \n• When working on projects with ADA, ICC A117 .1 and state accessibility standards, the most stringent of the standards should be followed  \nEssential Bobrick Amenities for Satisfying  \nOccupant Needs & Code Requirements  \nBobrick’s SureFlo® Automatic Soap Dispensers can be activated from a  \nwheelchair  \nBobrick’s recessed accessories conform to  \nprotruding objects guidelines  \nBobrick’s ADA-compliant vendor is the only model to unquestionably meet  \nADA Guidelines  \nBobrick’s grab bars meet ADA-compliant layouts  \nClear Floor Space Requirements  \n• Accommodate a single wheelchair of at least 30\" x 48\"  \n• Position clear floor space at lavatories, urinals and baby changing stations for forward approach • Allow for both left-and right-hand access  \nExamples of where clear floor space is necessary  \nMounting Heights  \n• “Operable parts” of accessories other than toilet tissue dispensers no more than 48 \" above the floor.  \n• Operable portions of toilet tissue dispensers to no lower than 15 \" .  \n• Where accessories are mounted above  \nan obstruction ,they must be located between 44 \" and 48 \" .  \n• Account for side and forward approach.  \n• Position one set of each type of dispenser outside the toilet compartment,  \non an accessible route.  \n|  |\n| --- |\n| |\n|  |\n\n| |\n| --- |\n|  |\n\nTurning Spaces  \n• Circular turning space  \n– Allows 180-degree or 360-degree turn  \n• T-shaped turning space  \n– Allows 3-point turn  \n– Can conserve space  \n• Portion of 60\" space can be under fixtures, lavatories or accessories as long as knee and toe clearance is provided.  \n60\" Diameter Turning Space  \nT-Shaped Turning Space  \nSpecial Considerations for Lavatories  \n• Place lavatory as close as possible to front edge of countertop.  \n• 34\" max above finish floor  \n• Knee clearance of 27\" min. from bottom of apron to finish floor.  \n• Knee clearance must extend 8\"min. under front edge of lavatory.  \nSpecial Considerations for Lavatories  \n• Clear floor space in front and under lavatory:  \n– 30\" wide by 48\" deep min.  \n– Toe clearance 17\" min. to 25\" max.  \n– Toe clearance at least 9\"above finish floor for full depth.  \n• Water supply, drain pipes and exposed surfaces:  \n– Insulated to protect against contact  \n– Install removable protective panel under lavatory.  \nControls & Operating Mechanisms  \nOperable parts:  \n• Push buttons  \n• Valves  \n• Knobs  \n• Levers  \n• Controls must be operable with one hand, without tight grasping, pinching of the fingers, or twisting of wrist and require less than 5 lbs. of force.  \n• Controls centered over sufficient clear floor space for both leftand right-hand approaches.  \nBobrick Accessories to Meet ADA Control & Operability Requirements","cbCaiom6ypW0IXA9","https://ap.wps.com/l/cbCaiom6ypW0IXA9","pdf",2103210,27,"English","# ADA and ICC/ANSI Standards\n## Clear Floor Space Requirements\n## Mounting Heights\n## Turning Spaces\n## Special Considerations for Lavatories\n## Controls & Operating Mechanisms","[{\"question\":\"Which accessibility standards must be followed for ADA restroom projects?\",\"answer\":\"Follow the most stringent of the applicable ADA, ICC A117 .1, and state accessibility standards to ensure full compliance.\"},{\"question\":\"What are the key clear floor space requirements for a single wheelchair?\",\"answer\":\"Provide at least 30\\\" x 48\\\" clear floor space and position it for forward approach at lavatories, urinals, and baby changing stations, allowing both left- and right-hand access.\"},{\"question\":\"What operability and force limits apply to restroom controls?\",\"answer\":\"Controls must be operable with one hand without tight grasping, pinching, or twisting, and must require less than 5 lbs. of force, with controls centered over sufficient clear floor space for both approaches.\"}]","APG-Accessible-Restrooms - ADA Accessibility Requirements | PDF",68]