[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-561597-105":59,"doc-detail-561597-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","apc-smart-ups-users-manual-1000va1500va-installation-and-operation","APC Smart-UPS - User’s Manual - 1000VA/1500VA - Installation and Operation","","APC Smart-UPS 1000VA/1500VA user manual provides installation and operating guidance for tower uninterruptible power supplies supporting 230VAC/120VAC/100VAC and XL model variants. It explains how the UPS prevents power disturbances from reaching computers and other equipment, including blackout, brownout, sag, and surge protection. The document covers unpacking, safe placement, connecting equipment and power through rear-panel ports, charging behavior, LED and alarm indicators, and software options like PowerChutePlus for monitoring and diagnostics.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/apc-smart-ups-users-manual-1000va1500va-installation-and-operation/561597/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/apc-smart-ups-users-manual-1000va1500va-installation-and-operation/561597.png","ImageObject",300,407,{"name":92,"@type":93},"Franzy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-13","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the UPS designed to protect against?","Question",{"text":112,"@type":113},"The UPS prevents blackouts, brownouts, sags, and surges from reaching connected computers and other valuable electronic equipment.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should the UPS be installed before connecting equipment?",{"text":117,"@type":113},"Read the Safety Instruction sheet before installing. Inspect the unit on receipt, place it in a sturdy location, and ensure the operating temperature and humidity are within specified limits.",{"name":119,"@type":110,"acceptedAnswer":120},"What do the front-panel LEDs and alarms indicate?",{"text":121,"@type":113},"The online LED shows utility power supply; when on battery, the UPS sounds four beeps every 30 seconds. Overload triggers a sustained alarm tone, and battery self-test failures prompt short beeps and a replace battery indication.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},561597,1791928129,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},2336478945519,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","User’s Manual English  \nAPC Smart-UPS®  \n1000VA/1500VA  \n230VAC/120VAC/100VAC  \n750XL/1000XL  \n230VAC/120VAC  \nTower  \nUninterruptible Power Supply  \n990-1062A 11/01  \nIntroduction  \nAmerican Power Conversion Corporation (APC) is the leading national and international manufacturer of state-of-the-art uninterruptible power supplies, redundant switches, power management software, and related equipment. APC products protect hardware, software, and data from power disturbances in business and government offices throughout the world.  \nThe APC Uninterruptible Power Supply (UPS) is designed to prevent blackouts, brownouts, sags, and surges from reaching your computer and other valuable electronic equipment. The UPS filters small utility line fluctuations and isolates your equipment from large disturbances by internally disconnecting from the utility line. The UPS provides continuous power from its internal battery until the utility line returns to safe levels or the battery is discharged.  \n1: INSTALLATION  \n Read the Safety Instruction sheet before installing the UPS.  \nUnpacking  \nInspect the UPS upon receipt. APC designed robust packaging for your product. However, accidentsand damage may occur during shipment. Notify the carrier and dealer if there is damage.  \nThe packaging is recyclable; save it for reuse or dispose of it properly.  \nCheck the package contents. The package contains the UPS, a literature kit containing one CD, one serial cable, one USB cable, product documentation and Safety Information.  \n230V models: Two IEC jumper cables are included and a utility connector plug is included for use on servers with permanently attached power cords.  \n The UPS is shipped with the battery disconnected.  \nPositioning the UPS  \nThe UPS is heavy. Select a location sturdy enough to handle the weight.  \nDo not operate the UPS where there is excessive dust or the temperature and humidity are outside the specified limits.  \nPLACEMENT  \n0º-40ºC (32º-104ºF) 0-95% Relative  \nHumidity 2.5cm (1in)  \n1  \nConnecting Equipment and Power to the UPS  \nSMART-UPS REAR PANEL  \n230V MODELS  \n120V/100V MODELS  \n1. Plug in the battery connector 􀀁 .  \n2. Connect equipment to the UPS. Note: Do not connect a laser printer to the UPS. A laser printer draws significantly more power than other types of equipment and may overload the UPS.  \n3. Add any optional accessories to the Smart-Slot 􀀁 .  \n4. Using the power cord, plug the UPS into a two-pole, three-wire, grounded receptacle only.  \nAvoid using extension cords.  \n• 230V models: A utility connector plug is included for use on servers with permanently attached power cords.  \n• 120V/100V models: The power cord is permanently attached to the rear panel of the UPS.  \n5. Turn on all connected equipment. To use the UPS as a master ON/OFF switch, be sure all connected equipment is switched ON. The equipment will not be powered until the UPS is turned on.  \n6. To power up the UPS press the  button on the front panel.  \n• The UPS charges its battery when it is connected to utility power. The battery charges to 90% capacity during the first three hours of normal operation. Do not expect full battery run capability during this initial charge period.  \n• 120V Models: Check the site wiring fault LED located on the rear panel. It lights up if the UPS is plugged into an improperly wired utility power outlet. Refer to Troubleshooting in this manual.  \n7. For additional computer system security, install PowerChutePlus® UPS Power Management and Diagnostic Software.  \n2  \nBASIC CONNECTORS  \nSerial Port  \nUSB Port  \nPower management software and interface kits can be used with the UPS. Use only interface kits supplied or approved by APC.  \n\n| | Use the APC supplied cable to connect to the Serial Port. DO NOT use a standard serial interface cable since it is incompatible with the UPS connector.\u003Cbr>Both Serial and USB Ports are provided. They cannot be used simultaneously. |\n| --- | --- |\n\nExternal Battery Pack Connector  \n","cbCaimUmrvhvspUE","https://ap.wps.com/l/cbCaimUmrvhvspUE","pdf",544424,18,"English","# Introduction\n# 1: INSTALLATION\n## Unpacking\n## Positioning the UPS\n## Connecting Equipment and Power to the UPS\n# 2: OPERATION\n## SMART-UPS FRONT PANEL\n## Power On / Power Off / Online / AVR Trim","[{\"question\":\"What is the UPS designed to protect against?\",\"answer\":\"The UPS prevents blackouts, brownouts, sags, and surges from reaching connected computers and other valuable electronic equipment.\"},{\"question\":\"How should the UPS be installed before connecting equipment?\",\"answer\":\"Read the Safety Instruction sheet before installing. Inspect the unit on receipt, place it in a sturdy location, and ensure the operating temperature and humidity are within specified limits.\"},{\"question\":\"What do the front-panel LEDs and alarms indicate?\",\"answer\":\"The online LED shows utility power supply; when on battery, the UPS sounds four beeps every 30 seconds. Overload triggers a sustained alarm tone, and battery self-test failures prompt short beeps and a replace battery indication.\"}]","APC Smart-UPS - User’s Manual - 1000VA/1500VA - Installation and Operation | PDF",1791806341,45]