[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-363443-105":59,"doc-detail-363443-en":135},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":128,"head_meta":130,"extra_data":132,"updated_unix":134},105,"en","allowable-ampacity-tables-nfpa-70-nec-2023-table-310163101731015","Allowable Ampacity Tables - NFPA 70: NEC-2023 - Table 310.16/310.17/310.15","","Allowable ampacity tables from NFPA 70 (NEC-2023) list ampacities for insulated conductors based on conductor size (AWG and kcmil), conductor type, and temperature rating at 60°C, 75°C, and 90°C. The tables cover conductors in raceway, cable, or earth (directly buried) and single-insulated conductors in free air, distinguishing copper and aluminum (or copper-clad aluminum). Guidance includes ambient temperature correction factors for 30°C reference and adjustment factors for more than three current-carrying conductors, with usage and overcurrent protection notes.",{"@graph":69,"@context":127},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/allowable-ampacity-tables-nfpa-70-nec-2023-table-310163101731015/363443/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/allowable-ampacity-tables-nfpa-70-nec-2023-table-310163101731015/363443.png","ImageObject",300,407,{"name":92,"@type":93},"Hazel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",37,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119,123],{"name":110,"@type":111,"acceptedAnswer":112},"What determines which ampacity value to use in Table 310.16?","Question",{"text":113,"@type":114},"Choose the conductor size (AWG or kcmil), the conductor temperature rating (60°C/75°C/90°C), and the conductor type (e.g., TW, UF or THHN/XHHW family) for the specified installation condition in raceway, cable, or earth directly buried.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How are ampacities adjusted when the ambient temperature is not 30°C (86°F)?",{"text":118,"@type":114},"Use Table 310.15(B)(1)(1) to obtain the ambient temperature correction factor for the actual ambient temperature, then multiply the ampacities from the ampacity tables by that factor.",{"name":120,"@type":111,"acceptedAnswer":121},"How are ampacities adjusted when there are more than three current-carrying conductors?",{"text":122,"@type":114},"Use Table 310.15(C)(1) adjustment factors based on the number of current-carrying conductors and apply the stated percent-of-values adjustment to the ampacities (including the note about counting spare conductors and adjustment per 310.15(E) and (F)).",{"name":124,"@type":111,"acceptedAnswer":125},"What does Table 310.17 cover compared with Table 310.16?",{"text":126,"@type":114},"Table 310.17 applies to ampacities of single-insulated conductors in free air, while Table 310.16 applies to insulated conductors in raceway, cable, or earth directly buried.","https://schema.org",{"og:url":83,"og:type":129,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":131,"canonical":83},"index,follow",{"doc_id":133,"site_id":62},363443,1790227523,{"code":4,"msg":5,"data":136},{"doc_id":133,"user_id":137,"nickname":92,"user_avatar":138,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":139,"file_id":140,"file_url":141,"file_type":142,"file_size":143,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":81,"language":144,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":145,"faqs":146,"seo_title":147,"seo_description":67,"update_tm":148,"read_time":39,"preview_page_count":81,"preview_urls":149},137441390410,"https://ap-avatar.wpscdn.com/avatar/2000252f4ab5702993?_k=1776741390130283984","Allowable Ampacity Tables    \nNFPA 70: NEC-2023  \nTable 310.16  \nAmpacities Of Insulated Conductors with Not More Than Three Current-Carrying Conductors In Raceway, Cable, or Earth (Directly Buried)  \nSize  \nAWGor kcmil  \n\n| Temperature Rating of Conductor |  |  |\n| --- | --- | --- |\n| 60°C\u003Cbr>(140°F) | 75°C\u003Cbr>(167°F) | 90°C\u003Cbr>(194°F) |\n| Type:\u003Cbr>TW, UF | Type:\u003Cbr>RHW, THHW,\u003Cbr>THW, THWN,\u003Cbr>XHHW, XHWN,\u003Cbr>ZW | Type:\u003Cbr>TBS, SA, SIS, FEP, FEPB, MI, PFA, RHH, RHW-2, THHN, THHW, THW-2, THWN-2, USE-2, XHH, XHHW, XHHW-2, XHWN, XHWN-2, XHHN, Z, ZW-2 |\n| COPPER |  |  |\n\n18*  \n16*  \n14*  \n12*  \n10*  \n8 6  \n4 3  \n2 1  \n1/0  \n2/0  \n3/0  \n4/0  \n250  \n300  \n350  \n400  \n500  \n600  \n700  \n750  \n800  \n900  \n1000  \n1250  \n1500  \n1750  \n2000  \n-  \n-  \n15  \n20  \n30  \n40  \n55  \n70  \n85  \n95  \n110  \n125  \n145  \n165  \n195  \n215  \n240  \n260  \n280  \n320  \n350  \n385  \n400  \n410  \n435  \n455  \n495  \n525  \n545  \n555  \n-  \n-  \n20  \n25  \n35  \n50  \n65  \n85  \n100  \n115  \n130  \n150  \n175  \n200  \n230  \n255  \n285  \n310  \n335  \n380  \n420  \n460  \n475  \n490  \n520  \n545  \n590  \n625  \n650  \n665  \n14  \n18  \n25  \n30  \n40  \n55  \n75  \n95  \n115  \n130  \n145  \n170  \n195  \n225  \n260  \n290  \n320  \n350  \n380  \n430  \n475  \n520  \n535  \n555  \n585  \n615  \n665  \n705  \n735  \n750  \nNotes:  \n1. Section 310. 15(B) shall be referenced for ampacity correction factors where the ambient temperature is other than 30°C (86°F) .  \n2. Section 310. 15(C)(1) shall be referenced for than three current-carrying conductors.  \n3. Section 310.16 shall be referenced for conditions of use.  \n*Section 240. 4(D) shall be referenced for conductor overcurrent protection limitations, except as modified elsewhere by the Code. Overcurrent protection for conductor types marked with an asterisk shall not exceed 7 amperes AWG18, 10 amperes for AWG16, 15 amperes for AWG14, 20 amperes for AWG12, and 30 amperes for AWG10, after any correction factors for ambient temperature and number of conductors have been applied.  \nTable 310.17  \nAmpacities of Single-Insulated Conductors in Free Air  \nSize  \nAWGor kcmil  \n18  \n16  \n14*  \n12*  \n10*  \n8 6  \n4 3  \n2 1  \n1/0  \n2/0  \n3/0  \n4/0  \n250  \n300  \n350  \n400  \n500  \n600  \n\n| Temperature Rating of Conductor |  |  |\n| --- | --- | --- |\n| 60°C\u003Cbr>(140°F) | 75°C\u003Cbr>(167°F) | 90°C\u003Cbr>(194°F) |\n| Type:\u003Cbr>TW, UF | Type:\u003Cbr>RHW, THHW,\u003Cbr>THW, THWN,\u003Cbr>XHHW, XHWN,\u003Cbr>ZW | Type:\u003Cbr>TBS, SA, SIS, FEP, FEPB, MI, PFA, RHH, RHW-2, THHN, THHW, THW-2, THWN-2, USE-2, XHH, XHHW, XHHW-2, XHWN, XHWN-2, XHHN, Z, ZW-2 |\n| COPPER |  |  |\n\n-  \n-  \n25  \n30  \n40  \n60  \n80  \n105  \n120  \n140  \n165  \n195  \n225  \n260  \n300  \n340  \n375  \n420  \n455  \n515  \n575  \n-  \n-  \n30  \n35  \n50  \n70  \n95  \n125  \n145  \n170  \n195  \n230  \n265  \n310  \n360  \n405  \n445  \n505  \n545  \n620  \n690  \n18  \n24  \n35  \n40  \n55  \n80  \n105  \n140  \n165  \n190  \n220  \n260  \n300  \n350  \n405  \n455  \n500  \n570  \n615  \n700  \n780  \n700 630 755 850  \nNotes:  \n1. Section 310. 15(B) shall be referenced for ampacity correction factors where the ambient temperature is other than 30°C (86°F) .  \n2. Section 310.17 shall be referenced for conditions of use.  \n*Section 240. 4(D) shall be referenced for conductor overcurrent protection limitations, except as modified elsewhere by the Code. Overcurrent protection for conductor types marked with an asterisk shall not exceed 15 amperes for AWG14, 20 amperes for AWG12, and 30 amperes for AWG10, after any correction factors for ambient temperature and number of conductors have been applied.  \nAllowable Ampacity Tables    \nNFPA 70: NEC-2023  \nTable 310.15(B)(1)(1)  \nAmbient Temperature Correction Factors Based on 30°C (86° F)  \nFor ambient temperatures other than 30°C (86°F), multiply the ampacities specified in the ampacity tables by the appropriate correction factor shown below.  \n\n| Ambient\u003Cbr>Temperature |  | Temperature Rating of Conductor |  |  |\n| --- | --- | --- | --- | --- |\n| °C | °F | 60°C\u003Cbr>(140°F) | 75°C\u003Cbr>(167°F) | 90°C\u003Cbr>(194°F) |\n\n\u003C10 11-15  \n16-20 21-25  \n26-30 31-35  \n36-40 41-45 ","cbCaidNT0cPEQICP","https://ap.wps.com/l/cbCaidNT0cPEQICP","pdf",135595,"English","# NFPA 70: NEC-2023 - Allowable Ampacity Tables\n## Table 310.16 - Ampacities of Insulated Conductors (Raceway, Cable, Earth)\n## Table 310.17 - Ampacities of Single-Insulated Conductors (Free Air)\n## Table 310.15(B)(1)(1) - Ambient Temperature Correction Factors\n## Table 310.15(C)(1) - Adjustment Factors for More Than Three Current-Carrying Conductors","[{\"question\":\"What determines which ampacity value to use in Table 310.16?\",\"answer\":\"Choose the conductor size (AWG or kcmil), the conductor temperature rating (60°C/75°C/90°C), and the conductor type (e.g., TW, UF or THHN/XHHW family) for the specified installation condition in raceway, cable, or earth directly buried.\"},{\"question\":\"How are ampacities adjusted when the ambient temperature is not 30°C (86°F)?\",\"answer\":\"Use Table 310.15(B)(1)(1) to obtain the ambient temperature correction factor for the actual ambient temperature, then multiply the ampacities from the ampacity tables by that factor.\"},{\"question\":\"How are ampacities adjusted when there are more than three current-carrying conductors?\",\"answer\":\"Use Table 310.15(C)(1) adjustment factors based on the number of current-carrying conductors and apply the stated percent-of-values adjustment to the ampacities (including the note about counting spare conductors and adjustment per 310.15(E) and (F)).\"},{\"question\":\"What does Table 310.17 cover compared with Table 310.16?\",\"answer\":\"Table 310.17 applies to ampacities of single-insulated conductors in free air, while Table 310.16 applies to insulated conductors in raceway, cable, or earth directly buried.\"}]","Allowable Ampacity Tables - NFPA 70: NEC-2023 - Table 310.16/310.17/310.15 | PDF",1790151288,[150,154,158],{"page_no":8,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/54f5d5fb6978f2081f38d12ff15bbd5d.webp",983,1272,{"page_no":14,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6e6c65ebff8c7d610f4b8117226491dc.webp",982,1270,{"page_no":81,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6ad0bfee879405a66efa475b9bd2fa6a.webp",981,1269]