[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650514-105":59,"doc-detail-650514-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","aisi-s202-20-code-of-standard-practice-for-cold-formed-steel-structural-framing-2020-edition","AISI S202-20 - Code of Standard Practice for Cold-Formed Steel Structural Framing - 2020 Edition","","AISI S202-20 provides a state-of-the-art, voluntary model code addressing trade practices for the design, fabrication, and installation of cold-formed steel structural framing products. It sets guidance for contractual relationships while clarifying that the code does not override contract documents, legal building regulations, or sound professional judgment. It also specifies applicability limits, excluding certain nonstructural members and other steel systems covered by separate standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/aisi-s202-20-code-of-standard-practice-for-cold-formed-steel-structural-framing-2020-edition/650514/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/aisi-s202-20-code-of-standard-practice-for-cold-formed-steel-structural-framing-2020-edition/650514.png","ImageObject",300,407,{"name":92,"@type":93},"Aldword","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does AISI S202-20 cover?","Question",{"text":112,"@type":113},"It addresses trade practices for the design, fabrication, and installation of cold-formed steel structural framing products, serving as a state-of-the-art guide and voluntary model for contracts.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Does AISI S202-20 replace legal building regulations or contracts?",{"text":117,"@type":113},"No. It is intended to supplement and amplify legal building regulations and is not meant to take precedence over the contract, construction documents, or good judgment for specific projects.",{"name":119,"@type":110,"acceptedAnswer":120},"What types of work are not covered by AISI S202-20?",{"text":121,"@type":113},"It is not applicable to nonstructural members such as interior drywall framing, and it also excludes structural steel, steel joists, steel deck, metal building systems, and rack structures, which are addressed elsewhere.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650514,1792900749,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},2336478940917,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","AISI S202-20  \nAISI STA N DA R D  \nCode of Standard Practice for Cold-Formed Steel Structural Framing  \n2020 Edition  \nAISI S202-20  \nAISI STA N DA R D  \nCode of Standard Practice for Cold-Formed Steel Structural Framing  \n2020 Edition  \nDISCLAIMER  \nThe material contained herein has been developed by the American Iron and Steel Institute (AISI) Committee on Framing Standards. The Committee has made a diligent effort to present accurate, reliable, and useful information on trade practices for fabrication and installation of cold-formed steel structural framing. The Committee acknowledges and is grateful for the contributions of the numerous engineers, manufacturers, contractors, and others who have contributed to the body of knowledge on the subject. Specific references are included in the Code of Standard Practice document.  \nWith anticipated improvements in understanding of the behavior of cold-formed steel framing and the continuing development of new technology, this material will become dated. It is anticipated that AISI will publish updates of this material as new information becomes available, but this cannot be guaranteed.  \nNo conflict between this Code of Standard Practice and any legal building regulation is intended. This Code of Standard Practice is intended only to supplement and amplify such legal building regulations and laws.  \nThe materials set forth herein are for general purposes only. They are not a substitute for competent professional advice. Application of this information to a specific project, particularly if included as part of a contract, should be reviewed by competent legal counsel. Anyone making use of the information set forth herein does so at their own risk and assumes any and all liability arising therefrom.  \n1st Printing – December 2020  \nProduced by American Iron and Steel Institute  \nCopyright American Iron and Steel Institute 2020  \nPREFACE  \nThe American Iron and Steel Institute Committee on Framing Standards has developed this Code of Standard Practice for Cold-Formed Steel Structural Framing ( Code of Standard Practice) to address trade practices for design, fabrication, and installation of cold-formed steel structural framing products.  \nThis Code of Standard Practice is intended to serve as a state-of-the-art guide as well as a voluntary model for establishing contractual relationships between various parties in a construction project where cold-formed steel structural materials, components, or assemblies are used. It is not intended to take precedence over the contract, construction documents, or the use of good judgment for specific construction projects and conditions. However, these provisions are considered suitable for reference or inclusion in contracts or construction documents and serve as a model for that purpose.  \nThis Code of Standard Practice is not applicable to nonstructural members, including but not limited to interior drywall framing, which is addressed by AISI S220, ASTM C645, and ASTM C754, or structural steel, structural steel joists, steel deck, metal building systems, or rack structures, which are addressed by AISC, SJI, SDI, MBMA, and RMI, respectively.  \nThe purpose of the Commentary is to provide a record of the reasoning behind and the justification for the various provisions of this Code of Standard Practice. The Commentary is included as non-mandatory background to provide a series of explanations, illustrations, and interpretations for the owner’s representatives, registered design professionals, contractors, suppliers, manufacturers, installers, and others.  \nThe readers who wish to have more complete information, or who may have questions which are not answered by the abbreviated presentation of the Commentary, should refer to the Referenced Documents listed in Section A3 .  \nThe Committee acknowledges and is grateful for the numerous engineers, manufacturers, contractors, and others who have contributed to the body of knowledge on the subject.  \nThe","cbCaihBRxl7zGE8F","https://ap.wps.com/l/cbCaihBRxl7zGE8F","pdf",557710,44,"English","# Preface\n## Purpose and scope\n## Applicability limits\n## Commentary purpose","[{\"question\":\"What does AISI S202-20 cover?\",\"answer\":\"It addresses trade practices for the design, fabrication, and installation of cold-formed steel structural framing products, serving as a state-of-the-art guide and voluntary model for contracts.\"},{\"question\":\"Does AISI S202-20 replace legal building regulations or contracts?\",\"answer\":\"No. It is intended to supplement and amplify legal building regulations and is not meant to take precedence over the contract, construction documents, or good judgment for specific projects.\"},{\"question\":\"What types of work are not covered by AISI S202-20?\",\"answer\":\"It is not applicable to nonstructural members such as interior drywall framing, and it also excludes structural steel, steel joists, steel deck, metal building systems, and rack structures, which are addressed elsewhere.\"}]","AISI S202-20 - Code of Standard Practice for Cold-Formed Steel Structural Framing - 2020 Edition | PDF",1792830752,111]