[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-463684-105":59,"doc-detail-463684-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","air-conditioning-load-data-generation-method-based-on-dtw-clustering-and-physically-constrained-timegan","Air Conditioning Load Data Generation Method Based on DTW Clustering and Physically Constrained TimeGAN","","Generating air-conditioning system load data is crucial for power grid scheduling and intelligent energy management, yet AC load curves are strongly nonstationary and shaped by seasonal changes and both outdoor meteorology and indoor activity or control strategies. Existing models often yield averaged distributions and lack explicit physical constraints, reducing temporal pattern fidelity and interpretability. This paper proposes a hybrid framework combining DTW clustering, a physically constrained TimeGAN, and an LSTM-based model selection scheme to improve temporal diversity and thermodynamic consistency, achieving strong dataset results.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/air-conditioning-load-data-generation-method-based-on-dtw-clustering-and-physically-constrained-timegan/463684/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/air-conditioning-load-data-generation-method-based-on-dtw-clustering-and-physically-constrained-timegan/463684.png","ImageObject",300,407,{"name":92,"@type":93},"WPS_1790064749","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-31","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is air-conditioning load data generation challenging?","Question",{"text":112,"@type":113},"AC load curves are strongly nonstationary and influenced by seasonal cycles, outdoor meteorological conditions, indoor activity patterns, and operational control strategies, creating periodicity, sudden shifts, and diverse temporal patterns.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What problem do existing data-driven generation models have?",{"text":117,"@type":113},"They often produce averaged distributions that lose specific temporal patterns, and they typically lack explicit physical constraints, which limits physical interpretability and can reduce physical realism.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the proposed method enforce physical consistency?",{"text":121,"@type":113},"It incorporates a parameter-free physical constraint mechanism based on intrinsic temperature-load correlations into the TimeGAN supervised loss, improving thermodynamic consistency even when sensor data are scarce.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},463684,1791120043,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":36,"preview_page_count":19,"preview_urls":145},3985747859154,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Article  \nAir Conditioning Load Data Generation Method Based on DTW Clustering and Physically Constrained TimeGAN  \nYu Li 1,2,*, Xiaoyu Yang 2, Dongli Jia 2, Wanxing Sheng 2, Keyan Liu 2 and Rongheng Lin 1  \n1 State Key Laboratory of Networking and Switching Technology, Beijing University of Posts and Telecommunications, Beijing 100876, China; [rhlin@bupt.edu.cn](rhlin@bupt.edu.cn)  \n2 China Electric Power Research Institute, Beijing 100892, China; [jiadl@epri.sgcc.com.cn](jiadl@epri.sgcc.com.cn) (D.J.)  \n* Correspondence: [2024140824@bupt.cn](2024140824@bupt.cn); Tel.: +86-187-3465-5529  \nAbstract  \nGenerating air-conditioning system load data is crucial for tasks such as power grid scheduling and intelligent energy management. Air-conditioning load data exhibit strong nonstationarity. Their load curves are influenced by seasonal variations and highly correlated with outdoor meteorological conditions, indoor activity patterns, and equipment operational strategies. These characteristics lead to pronounced periodicity, sudden shifts, and diverse data patterns. Existing load generation models tend to produce averaged distributions, which often leads to the loss of specific temporal patterns inherent in air-conditioning loads. Moreover, as purely data-driven models, they lack explicit physical constraints, resulting in generated data with limited physical interpretability. To address these issues, this paper proposes a hybrid generation framework that integrates the DTW clustering algorithm, a physically-constrained TimeGAN model, and an LSTM-based model selection mechanism. Specifically, DTW clustering is first employed to achieve structured data partitioning, thereby enhancing the model’s ability to recognize and model diverse temporal patterns. Subsequently, to overcome the dependency on detailed building parameters and extensive sensor networks, a parameter-free physical constraint mechanism based on intrinsic temperature-load correlations is incorporated into the TimeGAN supervised loss. This design ensures thermodynamic consistency even in sensor-scarce environments where only basic operational data is available. Finally, to address adaptability challenges in long-term sequence generation, an LSTM-based selection mechanism is designed to evaluate and select from clustered submodels dynamically. This approach facilitates adaptive temporal fusion within the generation strategy. Extensive experiments on air-conditioning load datasets from Southeast China demonstrate that the framework achieves a local similarity score of 0.98, outperforming the state-of-the-art model and the original TimeGAN by 11.4% and 13.3%, respectively.  \nReceived: 11 November 2025  \nRevised: 11 December 2025  \nAccepted: 17 December 2025  \nPublished: 22 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \nKeywords: time series generation; DTW clustering; TimeGAN; physical constraints; LSTM-based model selection  \n1. Introduction  \nAs one of the primary sources of energy consumption in building environments, the air-conditioning (AC) system plays a crucial role in determining overall building energy performance, power system load balance, and energy dispatching efficiency. However, in practical applications, acquiring usable AC load data through traditional physical monitoring faces significant hurdles, including data privacy concerns, sensor faults, high  \ndeployment costs, and insufficient historical samples. Therefore, it is of great importance to generate abundant and realistic AC load data using only limited historical information, without relying on extensive building parameters.  \nExisting time series generation models are mostly based on advanced deep generative architectures, such as Generative Adversarial Networks (GANs), Variational Autoencoders (VAEs), and Denoising Diffusion Pr","cbCaibqtgqVF6MLp","https://ap.wps.com/l/cbCaibqtgqVF6MLp","pdf",30620878,16,"English","# Introduction\n## Background and challenges of AC load data generation\n## Limitations of existing time series generative models\n# Proposed hybrid framework\n## DTW-based hierarchical clustering\n## Physically constrained TimeGAN with temperature-load correlation\n## LSTM-based dynamic submodel selection\n# Experiments and results\n## Dataset description and evaluation metrics\n## Comparative performance against baselines","[{\"question\":\"Why is air-conditioning load data generation challenging?\",\"answer\":\"AC load curves are strongly nonstationary and influenced by seasonal cycles, outdoor meteorological conditions, indoor activity patterns, and operational control strategies, creating periodicity, sudden shifts, and diverse temporal patterns.\"},{\"question\":\"What problem do existing data-driven generation models have?\",\"answer\":\"They often produce averaged distributions that lose specific temporal patterns, and they typically lack explicit physical constraints, which limits physical interpretability and can reduce physical realism.\"},{\"question\":\"How does the proposed method enforce physical consistency?\",\"answer\":\"It incorporates a parameter-free physical constraint mechanism based on intrinsic temperature-load correlations into the TimeGAN supervised loss, improving thermodynamic consistency even when sensor data are scarce.\"}]","Air Conditioning Load Data Generation Method Based on DTW Clustering and Physically Constrained TimeGAN | PDF",1790766955,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/0fb17ba5022346ab33c03fdb6f9570ba.webp",983,1390,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/8fe4586b75a94b50a7ee34b9fa17cb68.webp",982,1388,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/add6009e5ff87e818d3016c6932f0d23.webp",981,1387,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/560c468cfdec40648ccbc8ccfba7159d.webp",980,1385]