[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-detail-646230-en":3,"detail-sidebar-cat-0-en-105":30,"doc-seo-646230-105":81},{"code":4,"msg":5,"data":6},0,"success",{"doc_id":7,"user_id":8,"nickname":9,"user_avatar":10,"doc_module":4,"category_id":11,"category_name":12,"doc_title":13,"doc_description":14,"doc_content":15,"file_id":16,"file_url":17,"file_type":18,"file_size":19,"view_count":11,"is_deleted":4,"is_public":20,"is_downloadable":20,"audit_status":20,"page_count":21,"language":22,"language_code":23,"site_id":24,"html_lang":23,"table_of_contents":25,"faqs":26,"seo_title":27,"seo_description":14,"update_tm":28,"read_time":29,"preview_page_count":4},646230,1374410101428,"Boyslovefans","https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2",7,"Healthcare","AED Pro - Operator’s Guide - Chapter 1 Product Overview","Operator’s guide for the AED Pro and AED Pro A-W defibrillator system, including publication details, trademark and caution notices, indications for use, and contraindications. Covers system overview topics such as defibrillation, defibrillation modes (semiautomatic and manual), ECG monitoring, audio recording, nonrescue mode, data transfer, device configuration, standby behavior, automatic shutoff, and available accessories. Also outlines initial setup and starting procedures for clinical use, self-tests, battery installation, and early operational messages.","AED Pro®  \nAED Pro® A-W  \nOperator’s Guide  \nThe issue date for the AED Pro Operator’s Guide (REF 9650-0350-01 Rev. L) is June, 2019.  \nIf more than 3 years have elapsed since the issue date, contact ZOLL Medical Corporation to determine if additional product information updates are available.  \nCopyright © 2019 ZOLL Medical Corporation. All rights reserved. AED Plus, AED Pro, CPR-D-padz, M Series, Pedi-padz, PowerCharger, Real CPR Help, Rectilinear Biphasic, RescueNet, See-Thru CPR, Stat-padz, SurePower and ZOLL are trademarks or registered trademarks of ZOLL Medical Corporation in the United States and/or other countries.  \nAll other trademarks and registered trademarks are property of their respective owners.  \nCaution: Federal law restricts this device to sale by or on the order of a licensed practitioner.  \nIndication of use  \nThe AED Pro system is indicated for use on victims of cardiac arrest with apparent lack of circulation as indicated by:  \n• Unconsciousness  \n• Absence of breathing, and  \n• Absence of pulse and other signs of circulation.  \nThe device is also indicated for use when ECG monitoring is indicated to evaluate the patient’s heart rate or ECG morphology. The AED Pro system is indicated for adult and pediatric patients.  \nContraindication of use  \nNever use the unit for defibrillation when the patient  \n• Is conscious  \n• Is breathing, or  \n• Has a detectable pulse or other sign of circulation.  \nGeneral Information  \nFederal (U.S.A.) law restricts this defibrillator to sale by or on the order of a physician.  \nTable of Contents  \nIndication of use............................................................................................................................ iii  \nContraindication of use .......................................................................................................... iii  \nGeneral Information ............................................................................................................... iii  \nChapter 1 Product Overview  \nDefibrillation ........................................................................................................................ 1-2  \nDefibrillation Modes .................................................................................................... 1-2  \nSemiautomatic Mode Defibrillation and CPR Monitoring .................................................... 1-2  \nManual Mode Defibrillation ................................................................................................. 1-3  \nECG Monitoring .................................................................................................................. 1-3  \nAudio Recording ................................................................................................................. 1-4  \nNonrescue Mode ................................................................................................................ 1-5  \nData Transfer .............................................................................................................. 1-5  \nDevice Configuration .................................................................................................. 1-5  \nStandby State ..................................................................................................................... 1-5  \nAutomatic Shutoff................................................................................................................ 1-5  \nAccessories ........................................................................................................................ 1-6  \nA-W Accessories ........................................................................................................ 1-7  \nThe Front Panel .................................................................................................................. 1-8  \nDisplay Screen ......................................................................................................","cbCaihTnzJnVecAI","https://ap.wps.com/l/cbCaihTnzJnVecAI","pdf",2705481,1,122,"English","en",105,"# Indication of use\n# Contraindication of use\n# General Information\n# Chapter 1 Product Overview\n## Defibrillation\n## Defibrillation Modes\n## Semiautomatic Mode Defibrillation and CPR Monitoring\n## Manual Mode Defibrillation\n## ECG Monitoring\n## Audio Recording\n## Nonrescue Mode\n## Data Transfer\n## Device Configuration\n## Standby State\n## Automatic Shutoff\n## Accessories\n## The Front Panel\n## Display Screen\n# Chapter 2 Getting Started\n## Installing a Battery Pack\n## Preparing the Unit for Clinical Use\n## Performing a Self-Test\n## Preconnecting the Defibrillation Electrodes Cable\n## Messages\n# Chapter 3 Semiautomatic Mode\n## Applying Defibrillation Electrode Pads","[{\"question\":\"What patients is the AED Pro system indicated for?\",\"answer\":\"The AED Pro system is indicated for victims of cardiac arrest with apparent lack of circulation, including unconsciousness, absence of breathing, and absence of pulse or other signs of circulation. It is also indicated when ECG monitoring is used to evaluate heart rate or ECG morphology, for adult and pediatric patients.\"},{\"question\":\"When should the AED Pro system not be used for defibrillation?\",\"answer\":\"Do not use the unit for defibrillation when the patient is conscious, is breathing, or has a detectable pulse or other signs of circulation.\"},{\"question\":\"What is covered in the guide’s Chapter 1 Product Overview?\",\"answer\":\"Chapter 1 covers defibrillation and defibrillation modes (including semiautomatic and manual), ECG monitoring, audio recording, nonrescue mode, data transfer, device configuration, standby state, automatic shutoff, accessories, and front panel/display screen details.\"}]","AED Pro - Operator’s Guide - Chapter 1 Product Overview | PDF",1792753758,307,{"code":4,"msg":5,"data":31},[32,37,42,47,52,57,60,65,70,73,77],{"id":20,"doc_module":4,"doc_module_name":33,"category_name":34,"show_sort_weight":35,"slug":36},"Document","Story & Novel",90,"story-novel",{"id":38,"doc_module":4,"doc_module_name":33,"category_name":39,"show_sort_weight":40,"slug":41},2,"Literature",80,"literature",{"id":43,"doc_module":4,"doc_module_name":33,"category_name":44,"show_sort_weight":45,"slug":46},4,"Exam",70,"exam",{"id":48,"doc_module":4,"doc_module_name":33,"category_name":49,"show_sort_weight":50,"slug":51},5,"Comic",60,"comic",{"id":53,"doc_module":4,"doc_module_name":33,"category_name":54,"show_sort_weight":55,"slug":56},6,"Technology",50,"technology",{"id":11,"doc_module":4,"doc_module_name":33,"category_name":12,"show_sort_weight":58,"slug":59},40,"healthcare",{"id":61,"doc_module":4,"doc_module_name":33,"category_name":62,"show_sort_weight":63,"slug":64},8,"Research & Report",30,"research-report",{"id":66,"doc_module":4,"doc_module_name":33,"category_name":67,"show_sort_weight":68,"slug":69},9,"Religion & Spirituality",20,"religion-spirituality",{"id":68,"doc_module":4,"doc_module_name":33,"category_name":71,"show_sort_weight":68,"slug":72},"World Cup","world-cup",{"id":74,"doc_module":4,"doc_module_name":33,"category_name":75,"show_sort_weight":74,"slug":76},10,"Lifestyle","lifestyle",{"id":78,"doc_module":4,"doc_module_name":33,"category_name":79,"show_sort_weight":48,"slug":80},19,"General","general",{"code":4,"msg":82,"data":83},"ok",{"site_id":24,"language":23,"slug":84,"title":13,"keywords":85,"description":14,"schema_data":86,"social_meta":140,"head_meta":142,"extra_data":144,"updated_unix":145},"aed-pro-operators-guide-chapter-1-product-overview","",{"@graph":87,"@context":139},[88,102,122],{"@type":89,"itemListElement":90},"BreadcrumbList",[91,95,97,100],{"item":92,"name":93,"@type":94,"position":20},"https://docshare.wps.com","Home","ListItem",{"item":96,"name":33,"@type":94,"position":38},"https://docshare.wps.com/document/",{"item":98,"name":12,"@type":94,"position":99},"https://docshare.wps.com/document/healthcare/",3,{"item":101,"name":13,"@type":94,"position":43},"https://docshare.wps.com/document/aed-pro-operators-guide-chapter-1-product-overview/646230/",{"url":101,"name":13,"@type":103,"image":104,"author":109,"headline":13,"publisher":111,"fileFormat":114,"inLanguage":23,"description":14,"dateModified":115,"datePublished":116,"encodingFormat":114,"isAccessibleForFree":117,"interactionStatistic":118},"DigitalDocument",{"url":105,"@type":106,"width":107,"height":108},"https://docshare.wps.com/thumbnails/aed-pro-operators-guide-chapter-1-product-overview/646230.png","ImageObject",300,407,{"name":9,"@type":110},"Person",{"url":92,"name":112,"@type":113},"DocShare","Organization","application/pdf","2026-10-31","2026-10-23",true,{"@type":119,"interactionType":120,"userInteractionCount":11},"InteractionCounter",{"@type":121},"ViewAction",{"@type":123,"mainEntity":124},"FAQPage",[125,131,135],{"name":126,"@type":127,"acceptedAnswer":128},"What patients is the AED Pro system indicated for?","Question",{"text":129,"@type":130},"The AED Pro system is indicated for victims of cardiac arrest with apparent lack of circulation, including unconsciousness, absence of breathing, and absence of pulse or other signs of circulation. It is also indicated when ECG monitoring is used to evaluate heart rate or ECG morphology, for adult and pediatric patients.","Answer",{"name":132,"@type":127,"acceptedAnswer":133},"When should the AED Pro system not be used for defibrillation?",{"text":134,"@type":130},"Do not use the unit for defibrillation when the patient is conscious, is breathing, or has a detectable pulse or other signs of circulation.",{"name":136,"@type":127,"acceptedAnswer":137},"What is covered in the guide’s Chapter 1 Product Overview?",{"text":138,"@type":130},"Chapter 1 covers defibrillation and defibrillation modes (including semiautomatic and manual), ECG monitoring, audio recording, nonrescue mode, data transfer, device configuration, standby state, automatic shutoff, accessories, and front panel/display screen details.","https://schema.org",{"og:url":101,"og:type":141,"og:title":13,"og:site_name":112,"og:description":14},"article",{"robots":143,"canonical":101},"index,follow",{"doc_id":7,"site_id":24},1792876075]