[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-460386-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-460386-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","adhesive-property-of-different-bonding-agents-to-dentin-a-microscopic-study","Adhesive Property of Different Bonding Agents to Dentin - A Microscopic Study","","Bonding agents are essential for the longevity of restorative dental treatments by reducing microleakage at the tooth–restoration interface. The study compares five-, sixth-, seventh-, and eighth-generation bonding systems using standardized Class V cavities and methylene blue dye testing under a stereomicroscope. Sixty extracted human molars are grouped by bonding agent generation. Eighth-generation shows the least microleakage, seventh shows the most, and statistical tests confirm significant differences (P \u003C 0.05).",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/adhesive-property-of-different-bonding-agents-to-dentin-a-microscopic-study/460386/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/adhesive-property-of-different-bonding-agents-to-dentin-a-microscopic-study/460386.png","ImageObject",300,407,{"name":42,"@type":43},"anakgang17","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-29","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the main purpose of the study?","Question",{"text":63,"@type":64},"To compare microleakage characteristics of fifth-, sixth-, seventh-, and eighth-generation bonding agents on dentin using methylene blue dye under stereomicroscopy.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How were the microleakage measurements performed?",{"text":68,"@type":64},"Standardized Class V cavities were restored, then microleakage was assessed with methylene blue dye under a stereomicroscope.",{"name":70,"@type":61,"acceptedAnswer":71},"Which bonding agent generation performed best and which performed worst?",{"text":72,"@type":64},"The eighth-generation bonding agent showed the least microleakage, while the seventh generation showed the most.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},460386,1790758353,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":30,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":111,"preview_page_count":30,"preview_urls":143},962090883568,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Original Research  \nAdhesive Property of Different Bonding Agents to Dentin: A Microscopic Study  \nRamsha Rizwan, Deepak Kurup, Hrishita Majumder, Shreya Saurabh, Sourav Tikadar, Garima Sinha  \nDepartment of Conservative Dentistry and Endodontics, Hazaribag College of Dental Sciences and Hospital, Hazaribag, Jharkhand, India  \nSubmitted: 07‑Aug‑2025  \nRevised: 20‑Aug‑2025  \nAccepted: 25‑Aug‑2025  \nPublished: 17‑Dec‑2025  \nAbstract  \nBackground: Bonding agents play a critical role in the longevity and success of restorative dental treatments by minimizing microleakage at the tooth–restoration interface. The evolution from fifth‑ to eighth‑generation bonding systems reflects the ongoing efforts to simplify procedures while improving clinical outcomes. Materials and Methods: Sixty extracted human molars were divided into four groups based on the generation of bonding agents used: Fifth (Adper Single Bond 2), sixth (Clearfil SE), seventh (BeautiBond), and eighth (GC Premio Bond) . Standardized Class V cavities were prepared and restored. Microleakage was assessed using methylene blue dye under a stereomicroscope. Results: Eighth‑generation bonding agent demonstrated the least microleakage, while the seventh generation showed the most. Statistical analysis confirmed significant differences among the groups (P \u003C 0.05) . Conclusion: The eighth‑generation bonding agent showed superior performance in reducing microleakage compared to earlier generations, indicating its potential as the most effective adhesive system.  \nKeywords: Bonding agents, dentin adhesion, microleakage, restorative dentistry, stereomicroscope  \nIntroduction  \nAdhesive bonding in dentistry has significantly  \nevolved over the last few decades, revolutionizing restorative practices. The ability to create a strong bond between tooth structure and restorative materials isnot only essential for retention but also for preventing postoperative sensitivity, secondary caries, and pulpal damage due to microleakage. Microleakage, defined asthe microscopic passage of bacteria, fluids, molecules, or ions between the cavity wall and the restorative material, remains one of the most common causes of restoration failure.[1]  \nThe introduction of acid‑etching techniques by Buonocore laid the foundation for adhesive dentistry, which has since progressed through multiple generations of bonding agents. Fifth‑generation bonding agents represent a simplified two‑step “etch‑and‑rinse” system, combining primer and adhesive in one bottle. Though effective, they still require a separate etching step, which can lead to technique sensitivity.[2,3]  \n\n| Access this article online |  |\n| --- | --- |\n| Quick Response Code:\u003Cbr>| Website: [https://journals.lww.com/jpbs](https://journals.lww.com/jpbs) |\n|  | DOI: 10.4103/jpbs.jpbs_1400_25 |\n\nThe sixth‑generation bonding agents introduced the concept of “self‑etch primers,” reducing clinical steps and eliminating rinsing. This system comprises a separate primer and adhesive, enhancing user‑friendliness while maintaining efficacy. Seventh‑generation adhesives, or“all‑in‑one” adhesives, combined etching, priming, and bonding in a single solution to simplify procedures further. However, concerns regarding their lower bond strength and higher microleakage have been reported.[4] The eighth‑generation adhesives, the latest in the series, leverage advancements in nanotechnology to incorporate nanofillers and functional monomers that provide chemical bonding to hydroxyapatite, reduce technique sensitivity, and improve bond durability. They are  \nAddress for correspondence: Dr. Deepak Kurup,  \nDepartment of Conservative Dentistry and Endodontics, Hazaribag College of Dental Sciences and Hospital, NH33, Demotand, Hazaribag, Jharkhand, India.  \nE-mail: [droolez@gmail.com](droolez@gmail.com)  \nThis is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 License (CC BY-NC-ND), where it is permiss","cbCaiv0OZ0obw69X","https://ap.wps.com/l/cbCaiv0OZ0obw69X","pdf",565333,"English","# Abstract\n## Background\n## Materials and Methods\n## Results\n## Conclusion\n# Introduction\n# Materials and Methods","[{\"question\":\"What is the main purpose of the study?\",\"answer\":\"To compare microleakage characteristics of fifth-, sixth-, seventh-, and eighth-generation bonding agents on dentin using methylene blue dye under stereomicroscopy.\"},{\"question\":\"How were the microleakage measurements performed?\",\"answer\":\"Standardized Class V cavities were restored, then microleakage was assessed with methylene blue dye under a stereomicroscope.\"},{\"question\":\"Which bonding agent generation performed best and which performed worst?\",\"answer\":\"The eighth-generation bonding agent showed the least microleakage, while the seventh generation showed the most.\"}]","Adhesive Property of Different Bonding Agents to Dentin - A Microscopic Study | PDF",[144,148,152],{"page_no":22,"url":145,"width":146,"height":147},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/627cb2c855bd50575b228713e81b9125.webp",983,1272,{"page_no":26,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/efcb5a9f40dd0c969a669442f7799d35.webp",982,1270,{"page_no":30,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/04e2e60c7d1be079f4bd9543393ba058.webp",981,1269]