[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-389866-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-389866-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","addressable-detector-installation-manual-polarity-wiring-address-setting","Addressable Detector Installation Manual - Polarity, Wiring, Address Setting","","Installation instructions for an addressable detector, covering typical wiring, base installation, and detector head fitting. The guidance emphasizes observing detector polarity, maintaining earth screen continuity via an earth terminal, and ensuring clean, unobstructed base contacts. It specifies compatible MKII-A Series base models and provides step-by-step mounting and clockwise rotation to secure the detector. It also details electrical and environmental specifications, and explains dip-switch binary address setting with valid address constraints.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/addressable-detector-installation-manual-polarity-wiring-address-setting/389866/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/addressable-detector-installation-manual-polarity-wiring-address-setting/389866.png","ImageObject",300,407,{"name":42,"@type":43},"supergirl","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-19","2026-09-25",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",13,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What wiring rules must be followed when installing the detector?","Question",{"text":63,"@type":64},"Polarity must be observed on the detector as indicated on the schematic wiring diagram. An earth terminal is provided to maintain earth screen continuity, but it does not connect to the detector head.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How should the detector head be installed onto the base?",{"text":68,"@type":64},"Mate the detector onto the base and rotate clockwise until the detector loads into the base, then continue twisting clockwise to secure it. If construction is still in progress, fitting is allowed only if the dust cover remains in place.",{"name":70,"@type":61,"acceptedAnswer":71},"How is a unique detector address set using the dip switches?",{"text":72,"@type":64},"Each detector on the loop requires a unique address. Use the underside dip switch with 8 switches set as binary: ON is binary 0 and OFF is binary 1. Switching OFF adds specific values (1, 2, 4, 8, 16, 32, 64, 128) to the total, and addresses 0 (all ON) and 255 (all OFF) are not used.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},389866,1790437817,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,105,110,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":103,"slug":104},6,50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":112,"show_sort_weight":113,"slug":114},8,"Research & Report",30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":102,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":30,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":111},962088121634,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Typical Wiring Diagram  \nNote: Polarity must be observed on detector as indicated on schematic wiring diagram.  \nEarth terminal is provided to maintain earth screen continuity. It does not connect to this detector head.  \nBase Installation  \nConnect the zone wires to the appropriate terminal. Tighten with a correct sized screwdriver: a wrong screwdriver may damage the screw heads.  \nMake sure that the base contacts are clean and unobstructed.  \nNote, the base model No. for MKII-A Series is MKII-CB or MKII-CB/D.  \nDetector Head Installation  \nIf there is still minor construction work in progress, the head may be fitted, provided that the dust cover is still in place.  \nTo fit the detector, mate the detector onto the base and rotate the detector in clockwise until the detector loads into the base.  \nContinue to twist clockwise to secure it.  \nModel List  \n\n| Part No | Model No. | Description | CPR No. | LPCB No |\n| --- | --- | --- | --- | --- |\n| 80-210 | MKII-AOP | Analogue optical detector | 0832-CPR-F0075 | 330n/02 |\n| 80-212 | MKII-AHR | Analogue A1R heat detector | 0832-CPR-F0079 | 330q/04 |\n| 80-214 | MKII-AHF | Analogue A2S heat detector | 0832-CPR-F0081 | 330q/03 |\n| 80-216 | MKII-AOH | Analogue optical and A1 heat detector | 0832-CPR-F0077 | 330p/02 |\n| 80-218 | MKII-AHF/CS90 | Analogue CS heat detector | 0832-CPR-F1921 | 330q/05 |\n\nSpecifications  \n\n| Electrical Characteristics | Parameter |\n| --- | --- |\n| Loop voltage | 17 V – 28 V DC |\n| Maximum current consumption, at 24 VDC Switch-on surge, max 65 ms Quiescent\u003Cbr>Alarm (with no remote output. ) | 800uA\u003Cbr>500uA\u003Cbr>5mA |\n| Remote Output Capacity | Vloop@5mA |\n| Startup Time | 15S |\n| Maximum cable resistance | 50Ω |\n| Environmental |  |\n| Operating temperature | -10 °C to + 80 °C |\n| Operating humidity | 0-95% RH\u003Cbr>(no condensation or icing) |\n| Design environment | Indoor use only |\n| IP Rate | 42 |\n\nDetector Address Setting  \nEach detector fitted to the loop needs to have a unique address set. There can only be one device set to each address.  \nThe address is set with a dip switch located on the underside of the detector. There are 8 switches. Switches 1 to 8 are used to set a binary address, with the ON position being binary 0 (0 marked on the label), and the OFF position being binary 1. (1 marked on the label)  \nAddresses 0 (all ON) and 255 (all OFF) are not used. The address can be set by following the table opposite, or by following equation  \nSwitch 1 OFF = add 1 to total  \nSwitch 2 OFF = add 2 to total  \nSwitch 3 OFF = add 4 to total  \nSwitch 4 OFF = add 8 to total Switch 5 OFF = add 16 to total  \nSwitch 6 OFF = add 32 to total  \nSwitch 7 OFF = add 64 to total Switch 8 OFF = add 128 to total  \n\n| ADDR | 87654321 | ADDR | 87654321 | ADDR | 87654321 | ADDR | 87654321 |\n| --- | --- | --- | --- | --- | --- | --- | --- |\n| N/A | 00000000 | 32 | 00100000 | 64 | 01000000 | 96 | 01100000 |\n| 1 | 00000001 | 33 | 00100001 | 65 | 01000001 | 97 | 01100001 |\n| 2 | 00000010 | 34 | 00100010 | 66 | 01000010 | 98 | 01100010 |\n| 3 | 00000011 | 35 | 00100011 | 67 | 01000011 | 99 | 01100011 |\n| 4 | 00000100 | 36 | 00100100 | 68 | 01000100 | 100 | 01100100 |\n| 5 | 00000101 | 37 | 00100101 | 69 | 01000101 | 101 | 01100101 |\n| 6 | 00000110 | 38 | 00100110 | 70 | 01000110 | 102 | 01100110 |\n| 7 | 00000111 | 39 | 00100111 | 71 | 01000111 | 103 | 01100111 |\n| 8 | 00001000 | 40 | 00101000 | 72 | 01001000 | 104 | 01101000 |\n| 9 | 00001001 | 41 | 00101001 | 73 | 01001001 | 105 | 01101001 |\n| 10 | 00001010 | 42 | 00101010 | 74 | 01001010 | 106 | 01101010 |\n| 11 | 00001011 | 43 | 00101011 | 75 | 01001011 | 107 | 01101011 |\n| 12 | 00001100 | 44 | 00101100 | 76 | 01001100 | 108 | 01101100 |\n| 13 | 00001101 | 45 | 00101101 | 77 | 01001101 | 109 | 01101101 |\n| 14 | 00001110 | 46 | 00101110 | 78 | 01001110 | 110 | 01101110 |\n| 15 | 00001111 | 47 | 00101111 | 79 | 01001111 | 111 | 01101111 |\n| 16 | 00010000 | 48 | 00110000 | 80 | 01010000 | 112 | 01110000 |\n| 17 | 00010001 | 49 | 00110001 | 8","cbCaij3PjqFI6osb","https://ap.wps.com/l/cbCaij3PjqFI6osb","pdf",377083,"English","# Base Installation\n## Typical Wiring Diagram and Polarity\n## Detector Head Installation\n# Detector Models and Specifications\n## Model List\n## Electrical Characteristics\n# Detector Address Setting\n## Dip Switch Binary Addressing\n## Address Constraints and Setup Table","[{\"question\":\"What wiring rules must be followed when installing the detector?\",\"answer\":\"Polarity must be observed on the detector as indicated on the schematic wiring diagram. An earth terminal is provided to maintain earth screen continuity, but it does not connect to the detector head.\"},{\"question\":\"How should the detector head be installed onto the base?\",\"answer\":\"Mate the detector onto the base and rotate clockwise until the detector loads into the base, then continue twisting clockwise to secure it. If construction is still in progress, fitting is allowed only if the dust cover remains in place.\"},{\"question\":\"How is a unique detector address set using the dip switches?\",\"answer\":\"Each detector on the loop requires a unique address. Use the underside dip switch with 8 switches set as binary: ON is binary 0 and OFF is binary 1. Switching OFF adds specific values (1, 2, 4, 8, 16, 32, 64, 128) to the total, and addresses 0 (all ON) and 255 (all OFF) are not used.\"}]","Addressable Detector Installation Manual - Polarity, Wiring, Address Setting | PDF",1790328092]