[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663313-105":59,"doc-detail-663313-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","addition-plan-information-handout-drawing-submittal-requirements","Addition Plan Information Handout - Drawing Submittal Requirements","","Addition plan information handout describing drawing submittal requirements for the Building and Inspection Division. It specifies scale-to-size illustrations, sets of plans, required foundation and elevation views, and the inclusion of a survey/plot plan locating the project. It outlines expectations for floor plan content including dimensions, door and window placement, header/beam sizes, joist/rafter spacing, and insulation details, supported by example plan and section graphics.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/addition-plan-information-handout-drawing-submittal-requirements/663313/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/addition-plan-information-handout-drawing-submittal-requirements/663313.png","ImageObject",300,407,{"name":92,"@type":93},"Jiven","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How many sets of plans must be submitted for an addition proposal?","Question",{"text":112,"@type":113},"Submit two sets of plans drawn to scale.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What views are required when adding an area to an existing home?",{"text":117,"@type":113},"Provide a minimum of one elevation, one plan view per floor level, and one section view per area being added.",{"name":119,"@type":110,"acceptedAnswer":120},"What must be included on the floor plan drawing besides doors and windows?",{"text":121,"@type":113},"Include written dimensions, rough opening sizes, header and beam sizes and material types, joist/rafter/truss spacing, and the use of the new and adjoining rooms.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663313,1793226456,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":52},1099513958607,"https://ap-avatar.wpscdn.com/avatar/100002390cf8733938c?x-image-process=image/resize,m_fixed,w_180,h_180&k=1778829742770036399","Addition Plan Information Handout  \nThese illustrations are only examples. Your drawings must be to scale.  \nThese examples show the detail required for plan submittals to the Building and Inspection Division. From your drawings , plan reviewers should be able to build the project themselves.  \nThe following are required when submittting proposals:  \n• Two sets of plans, drawn to scale.  \n• A minimum of one elevation , one plan view per floor level and one section view per area being added.  \n• A survey/plot plan showing the location of your project. Call or visit the Building and Inspection Division to see if your property has a survey available.  \n• Although you do not need to draw plumbing , electrical or heating plans , separate permits are required. The building permit covers only structural , insulation and finish products.  \nPlan view: Foundation  \n• Locate addition in relation to existing home.  \n• Indicate whether the addition is a crawl space , full depth foundation or post footings.  \n• Include written dimensions and locations.  \n• If it is being built on post footings, the footings must be sized for submittal of plans.  \nSee graphic at right, below and page 2.  \n\n| Plan view:\u003Cbr>Foundation with posts\u003Cbr>Scale 1/4˝ = 1´ |\n| --- |\n| Bedroom\u003Cbr>Family room\u003Cbr> 10 ´ -0˝  \u003Cbr> 24˝FOOTING\u003Cbr>\u003Cbr>\u003Cbr>Addition\u003Cbr>2˝x 8˝ JOISTS\u003Cbr>16˝O.C.\u003Cbr>2-2˝x 8˝ BEAMS\u003Cbr>18˝FOOTING\u003Cbr>\u003Cbr> 24˝FOOTING\u003Cbr>\u003Cbr>12 ´ -0˝ |\n| Note: Provide written distances between posts. |\n\nExisting Addition Elevation  \nROOF  \nVENT  \nScale 1/4˝ = 1´  \nLaundry room  \nRec  \nroom  \nPlan view: Foundation with crawl space  \nScale 1/4˝ = 1´  \n10´ -0˝  \n18˝ x 24˝  \nACCESS  \n8” CONCRETE R-15 FOAM INSULATION  \n1/2” GYPSUM BOARD  \nBLOCK-5 Course  \n8˝ x 16˝ FOOTING  \n12 ´ -0˝  \nCommunity Development Building and Inspection  \n1800 W. Old Shakopee Road Bloomington MN 55431-3027  \nPH 952-563-8930 FAX 952-563-8949 TTY 952-563-8740  \n[BloomingtonMN.gov](BloomingtonMN.gov)  \nweb_ 53ttdrawplan pg 1 of 3 (06/15)  \nPlan view: Floor  \n• Draw to scale.  \n• Note the scale you use on the drawing.  \n• Include written dimensions on the plan.  \n• Locate all doors and windows.  \n• Provide rough opening sizes and U-values from the manufacturer for each window unit and door.  \n• Provide header and beam sizes, as well as type of material being used. (e.g. 2-2\" x 10\" Doug Fir or 2-9-1/2\" LVLs.)  \n• Provide a floor plan for each level being built.  \n• Indicate direction and spacing of joists, rafters/trusses, e.g. 12\", 16\" or 24\" on center.  \n• Indicate the use (e.g. bathroom, family room, bedroom) of the new room(s) and those adjoining the addition.  \nSee graphic below. (Note: Materials, types and sizes are given for example only.)  \n\n| First floor\u003Cbr>Scale 1/4˝ = 1´ |\n| --- |\n| Laundry room\u003Cbr>\u003Cbr>Family\u003Cbr>room\u003Cbr>2-2”x 8”HEADER\u003Cbr>\u003Cbr>\u003Cbr>WINDOW\u003Cbr>Assembly size = X square feet or\u003Cbr>Rough-opening = width times height GAS\u003Cbr>Description\u003Cbr>A* FIREPLACE\u003Cbr>  10´ -0˝  \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>Dining room \u003Cbr>\u003Cbr>2-2˝ x 10˝ HEADER\u003Cbr>\u003Cbr>DOOR\u003Cbr>Rough opening 3´ -3˝ x 6´ -10˝ U-value = 0.32\u003Cbr>2-2˝ x 10˝ HEADER\u003Cbr>\u003Cbr>\u003Cbr>WINDOW\u003Cbr>Rough-opening = 2´ -2˝ x 3´ -5˝\u003Cbr>Vinyl clad/double hung/low-e/U-value = 0.32 maximum\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>12 ´ -0˝\u003Cbr>MF RD TRUSSES\u003Cbr>24˝ O. .C |\n| * Location of Section A-A on next page. |\n\nweb_ 53ttdrawplan pg 2 of 3 (06/15)  \nSection view  \nIf more than one area is being built , provide one section view for each area. See graphic below.  \n(Note: Materials, types and sizes are given for example only.)  \nINSULATED 5/8˝GYPSUM ATTIC ACCESS BOARD  \nRough opening size 22\" X 30\"  \nVAPOR RETARDER  \n4-Mil  \n2˝ x 6˝ STUDS 16˝ O.C  \n1/2˝GYPSUM BOARD  \n3/4˝TONGUE AND GROOVE PLYWOOD  \nR-20 RIM INSULATION  \n18\" CRAWLSPACE  \nR-15 RIGID INSULATION 1/2˝GYPSUM  \nGRADE  \n2˝ X 6˝ TREATED  \nSILL PLATE with sill sealer  \n1/2˝ PLYWOOD SHEATHING  \nWATER RESISTANT BARRIER  \n(Name specific housewrap and/or felt paper)  \nSIDING  \n(Type of material, e.g. vinyl, cedar, stucco, etc.)  \nAIR CHUTE","cbCaiurDde3l4UZ0","https://ap.wps.com/l/cbCaiurDde3l4UZ0","pdf",1412947,"English","# Plan Submittal Requirements\n## Required Views and Sets\n## Survey / Plot Plan\n## Plumbing, Electrical, and Heating Permits\n# Plan View: Foundation\n## Placement and Foundation Type\n## Dimensions and Post Footings\n# Existing Addition Elevation\n# Plan View: Floor\n## Scale, Dimensions, Openings\n## Headers, Beams, and Rough Openings\n## Joist/Rafter Spacing and Room Use\n# Section View\n## Insulation, Framing, and Barriers\n## Anchor Bolts and Footing Depth\n# Survey / Plot Plan Example","[{\"question\":\"How many sets of plans must be submitted for an addition proposal?\",\"answer\":\"Submit two sets of plans drawn to scale.\"},{\"question\":\"What views are required when adding an area to an existing home?\",\"answer\":\"Provide a minimum of one elevation, one plan view per floor level, and one section view per area being added.\"},{\"question\":\"What must be included on the floor plan drawing besides doors and windows?\",\"answer\":\"Include written dimensions, rough opening sizes, header and beam sizes and material types, joist/rafter/truss spacing, and the use of the new and adjoining rooms.\"}]","Addition Plan Information Handout - Drawing Submittal Requirements | PDF"]