[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-653052-105":3,"detail-sidebar-cat-0-en-105":80,"doc-detail-653052-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":73,"head_meta":75,"extra_data":77,"updated_unix":79},105,"en","adc-44-parts-manual-parts-manual","ADC-44 Parts Manual - Parts Manual","","American Dish Service ADC-44 L-R/R-L conveyor dishwasher parts manual includes replacement-part and compliance guidance for trained service personnel. It outlines regulatory certification constraints, warns against aftermarket or modified parts, and specifies hazards and safe handling steps when servicing electrical components. The manual also provides precautions for chemical feeders and controls, covering PPE, chemical corrosiveness, safe de-liming procedures, container handling, leak/spill reporting, and injury prevention during operation and door usage.",{"@graph":14,"@context":72},[15,34,55],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/adc-44-parts-manual-parts-manual/653052/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/adc-44-parts-manual-parts-manual/653052.png","ImageObject",300,407,{"name":42,"@type":43},"Bintang","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-27","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":26},"InteractionCounter",{"@type":54},"ViewAction",{"@type":56,"mainEntity":57},"FAQPage",[58,64,68],{"name":59,"@type":60,"acceptedAnswer":61},"Who is allowed to replace parts in American Dish Service equipment?","Question",{"text":62,"@type":63},"Replacement parts must be installed by those trained in operation and service of commercial dishmachines. Aftermarket or modified parts are not compliant with regulatory standards and are not authorized by ADS.","Answer",{"name":65,"@type":60,"acceptedAnswer":66},"What electrical safety precautions are required before servicing?",{"text":67,"@type":63},"Disconnect power and perform lock-out/tag-out before working in the control box or on electrical parts. Verify electrical terminals are tight before reconnecting power, and replace protective covers after servicing.",{"name":69,"@type":60,"acceptedAnswer":70},"What PPE and handling practices are recommended when working with chemical feeders and controls?",{"text":71,"@type":63},"Wear approved personal protective equipment, including chemically resistant gloves and safety eye-wear. Use chemical-resistant gloves and safety goggles when changing chemical buckets, secure chemical lines, and immediately wash with fresh water and seek medical attention if chemicals contact skin or eyes.","https://schema.org",{"og:url":32,"og:type":74,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":76,"canonical":32},"index,follow",{"doc_id":78,"site_id":7},653052,1793074244,{"code":4,"msg":81,"data":82},"success",[83,87,91,95,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":84,"show_sort_weight":85,"slug":86},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":88,"show_sort_weight":89,"slug":90},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":92,"show_sort_weight":93,"slug":94},"Exam",70,"exam",{"id":96,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},5,"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":96,"slug":129},19,"General","general",{"code":4,"msg":81,"data":131},{"doc_id":78,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":26,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145},962085564381,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","EFFECTIVE: AUGUST 15, 2019  \nAmerican Dish Service  \nADS CONVEYOR DISHWASHER  \nMODELS: ADC-44 L-R/R-L  \nPARTS MANUAL  \n900 Blake Street Edwardsville, Kansas 66111  \n(913)422-3700  \nAmerican Dish Service  \nThe American Dish Service part numbers contained in this publication are replacement parts for equipment listed with governmental and regulatory agencies and are specified to maintain the regulatory mark and certification. These parts must only be replaced by those who are trained in the operation and service of commercial dishmachines. Aftermarket parts or modified parts are not compliant or listed with the standards of governmental and regulatory agencies; aftermarket parts are not authorized by ADS for replacement repairs. ADS will not be responsible for any liability If parts are used in the repair of the machine that are not ADSͲspecified, by those installing nonͲcertified replacement parts or attempts to change the machine’s cycle or operation other than as designed and certified. Read the warnings and cautions provided below before working on or replacing parts on any ADS equipment.  \nThe installation of electrical parts contained in this publication require the following precautions:  \nThe electrical power supplied to this machine is an imminent hazard to life that could result in severe bodily injury or death if not properly installed or connected correctly. When working in the control box or on electrical parts, always disconnect power and perform the appropriate lockͲout/tagͲout proceedure before servicing. Replace the cover to the control box and other protective covers when finished with servicing this equipment before returning the machine to normal operation.  \nLOOSE ELECTRICAL CONNECTIONS: Damage to the equipment can occur if the following precautions are not observed. Before connecting power to the machine, check all electrical terminals in the control box. Screws can loosen in transit. Loose connections on high amp load terminals such as the pump motor and tank heaters will cause wire burning and component damage during operation and will not be covered under ADS warranty.  \n“CLEAN CIRCUIT” means the electrical circuit breaker for the dishmachine supplies no other outlets, machines, or lights. GFCI outlets are not recommended for commercial dishmachines; ADS recommends that a singleͲrack machine be installed with the wire connection (hardͲwired) directly from the circuit breaker. All high temp and conveyor equipment must be hard wired. If a plug and socket are used to provide electrical power to a dishmachine in a commercial kitchen, then according to electrical code it must be a GFCI, but not all GFCIs are the same. They must be rated for the Amp draw for the designed circuit.  \nFor Reference: The NEC Article 210.8 regarding GFCI Protection (B) Other Than Dwelling Units (2) Commercial and Institutional Kitchens. All 15 and 20A, 125V receptacles installed in kitchens, even those that do not supply the countertop surface, must be GFCI protected.  \n  WARNING   \nThe chemical feeders and controls contained in this publication require the following precautions:  \nREAD Manufacturer’s Manual before Using this Product. For your safety read and observe all warnings in these instructions.  \nWhile performing installation of parts described in this booklet, wear approved Personal Protective Equipment, including chemically resistant gloves and Safety EyeͲWear.  \nCHEMICALS: There are potentially hazardous situations when working with industrial cleaning chemicals for dishmachines. See chemical manufacturer’s safe practices and SDS or MSDS sheets for handling and installing chemicals and supply containers.  \nChemicals can damage or corrode plumbing and stainless parts of the dishmachine. Do not run chemical lines over controls or plumbing. Always secure chemical lines and check regularly for leaks. If not properly handled, chemicals can cause serious bodily injury. In the event of chemical contact to skin or eyes; wash imm","cbCaimktQh5jXx3u","https://ap.wps.com/l/cbCaimktQh5jXx3u","pdf",917730,46,"English","# Safety and Regulatory Compliance\n## Electrical Parts Precautions\n## “Clean Circuit” and GFCI Guidance\n## Chemical Feeders and Controls Precautions\n## De-liming, Containers, and Door Safety","[{\"question\":\"Who is allowed to replace parts in American Dish Service equipment?\",\"answer\":\"Replacement parts must be installed by those trained in operation and service of commercial dishmachines. Aftermarket or modified parts are not compliant with regulatory standards and are not authorized by ADS.\"},{\"question\":\"What electrical safety precautions are required before servicing?\",\"answer\":\"Disconnect power and perform lock-out/tag-out before working in the control box or on electrical parts. Verify electrical terminals are tight before reconnecting power, and replace protective covers after servicing.\"},{\"question\":\"What PPE and handling practices are recommended when working with chemical feeders and controls?\",\"answer\":\"Wear approved personal protective equipment, including chemically resistant gloves and safety eye-wear. Use chemical-resistant gloves and safety goggles when changing chemical buckets, secure chemical lines, and immediately wash with fresh water and seek medical attention if chemicals contact skin or eyes.\"}]","ADC-44 Parts Manual - Parts Manual | PDF",1792885399,116]